Toward endobronchial Ir-192 high-dose-rate brachytherapy therapeutic optimization

被引:8
|
作者
Gay, H. A. [1 ]
Allison, R. R.
Downie, G. H.
Mota, H. C.
Austerlitz, C.
Jenkins, T.
Sibata, C. H.
机构
[1] E Carolina Univ, Brody Sch Med, Dept Radiat Oncol, Greenville, NC 27858 USA
[2] E Carolina Univ, Brody Sch Med, Dept Internal Med, Pulm & Crit Care Med Sect, Greenville, NC 27858 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 11期
关键词
D O I
10.1088/0031-9155/52/11/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A number of patients with lung cancer receive either palliative or curative high-dose-rate (HDR) endobronchial brachytherapy. Up to a third of patients treated with endobronchial HDR die from hemoptysis. Rather than accept hemoptysis as an expected potential consequence of HDR, we have calculated the radial dose distribution for an Ir-192 HDR source, rigorously examined the dose and prescription points recommended by the American Brachytherapy Society (ABS), and performed a radiobiological-based analysis. The radial dose rate of a commercially available Ir-192 source was calculated with a Monte Carlo simulation. Based on the linear quadratic model, the estimated palliative, curative and blood vessel rupture radii from the center of an Ir-192 source were obtained for the ABS recommendations and a series of customized HDR prescriptions. The estimated radius at risk for blood vessel perforation for the ABS recommendations ranges from 7 to 9 mm. An optimized prescription may in some situations reduce this radius to 4 mm. The estimated blood perforation radius is generally smaller than the palliative radius. Optimized and individualized endobronchial HDR prescriptions are currently feasible based on our current understanding of tumor and normal tissue radiobiology. Individualized prescriptions could minimize complications such as fatal hemoptysis without sacrificing efficacy. Fiducial stents, HDR catheter centering or spacers and the use of CT imaging to better assess the relationship between the catheter and blood vessels promise to be useful strategies for increasing the therapeutic index of this treatment modality. Prospective trials employing treatment optimization algorithms are needed.
引用
收藏
页码:2987 / 2999
页数:13
相关论文
共 50 条
  • [21] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Mahdi Sadeghi
    Fatemah Taghdiri
    Pooneh Saidi
    Japanese Journal of Radiology, 2011, 29 : 324 - 329
  • [22] Comparison of calibration procedures for 192IR high-dose-rate brachytherapy sources
    Baltas, D
    Geramani, K
    Ioannidis, GT
    Hierholz, K
    Rogge, B
    Kolotas, C
    Müller-Sievers, K
    Milickovic, N
    Kober, B
    Zamboglou, N
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (03): : 653 - 661
  • [23] A METHOD TO CHECK TREATMENT TIME CALCULATIONS IN IR-192 HIGH-DOSE-RATE VOLUME IMPLANTS
    VENSELAAR, JLM
    BIERHUIZEN, HWJ
    KLOP, R
    MEDICAL PHYSICS, 1995, 22 (09) : 1499 - 1500
  • [24] INTERSTITIAL HIGH-DOSE-RATE AFTERLOADING RADIATION-THERAPY WITH IR-192 IN PROSTATE CARCINOMA
    BRAUN, J
    KNESCHAUREK, P
    HOFMANN, R
    SCHWEMMER, B
    LINDNER, H
    JOURNAL OF UROLOGY, 1987, 137 (04): : A358 - A358
  • [25] HIGH-DOSE RATE (HDR) IR-192 BRACHYTHERAPY APPLICATION OF BASAL CELL CARCINOMA
    Basaric, Borko
    Petrovic, Borislava
    Teodorovic, Milan
    Baucal, Milutin
    Rutonjski, Laza
    Cudic, Ozren
    Djuran, Branislav
    Mitric-Askovic, Milana
    RAD 2015: THE THIRD INTERNATIONAL CONFERENCE ON RADIATION AND APPLICATIONS IN VARIOUS FIELDS OF RESEARCH, 2015, : 65 - 68
  • [26] Comparative dosimetry of GammaMed Plus high-dose rate Ir-192 brachytherapy source
    Patel, N. P.
    Majumdar, B.
    Vijayan, V.
    JOURNAL OF MEDICAL PHYSICS, 2010, 35 (03) : 137 - 143
  • [27] Calibration of Ir-192 high dose rate brachytherapy source using different calibration procedures
    Bondel, Shwetha
    Ravikumar, Manickham
    Supe, Sanjay Sudhakar
    Reddy, Buchuppudi Rekha
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2014, 19 (03) : 151 - 156
  • [28] In-Phantom Calibration of High Dose Rate Ir-192 Brachytherapy Source - A Feasibility Study
    Mandiram, Kuppuswamy
    Senthil, G.
    Sundaram, Visalatchi
    Muthulingam, S.
    Karthik, S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [29] Treatment outcomes of high-dose-rate intracavitary brachytherapy for cervical cancer: a comparison of Ir-192 versus Co-60 sources
    Tantivatana, Thanatip
    Rongsriyam, Kanisa
    JOURNAL OF GYNECOLOGIC ONCOLOGY, 2018, 29 (05)
  • [30] Evaluation of the Performance of a Multiple-Array-Diode Detector for Quality Assurance Tests in High-Dose-Rate Brachytherapy with Ir-192 Source
    Harpool, K.
    Herman, T. De la Fuente
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2016, 43 (06) : 3468 - 3468