Surface EMG-force modelling for the biceps brachii and its experimental evaluation during isometric isotonic contractions

被引:14
|
作者
Cao, Hua [1 ]
Boudaoud, Sofiane [2 ]
Marin, Frederic [2 ]
Marque, Catherine [2 ]
机构
[1] HEI, Dept EEA, Lille, France
[2] Univ Technol Compiegne, UMR CNRS Biomecan & Bioingn 7338, Ctr Rech Royallieu, F-60205 Compiegne, France
关键词
sensitivity analysis; motor unit recruitment scheme; muscle force; Monte-Carlo simulations; isometric contractions; biomechanics; modelling; sEMG; UNIT RECRUITMENT STRATEGIES; MOTOR-UNIT; MUSCLE FORCE; ELECTROMYOGRAPHIC SIGNAL; MYOELECTRIC SIGNAL; JOINT MOMENTS; POWER SPECTRA; ELBOW JOINT; FREQUENCY; SIMULATION;
D O I
10.1080/10255842.2013.867952
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The aim of this study was to evaluate a surface electromyography (sEMG) signal and force model for the biceps brachii muscle during isotonic isometric contractions for an experimental set-up as well as for a simulation. The proposed model includes a new rate coding scheme and a new analytical formulation of the muscle force generation. The proposed rate coding scheme supposes varying minimum and peak firing frequencies according to motor unit (MU) type (I or II). Practically, the proposed analytical mechanogram allows us to tune the force contribution of each active MU according to its type and instantaneous firing rate. A subsequent sensitivity analysis using a Monte Carlo simulation allows deducing optimised input parameter ranges that guarantee a realistic behaviour of the proposed model according to two existing criteria and an additional one. In fact, this proposed new criterion evaluates the force generation efficiency according to neural intent. Experiments and simulations, at varying force levels and using the optimised parameter ranges, were performed to evaluate the proposed model. As a result, our study showed that the proposed sEMG-force modelling can emulate the biceps brachii behaviour during isotonic isometric contractions.
引用
收藏
页码:1014 / 1023
页数:10
相关论文
共 50 条
  • [41] Reliability of near-infrared spectroscopy for measuring biceps brachii oxygenation during sustained and repeated isometric contractions
    Muthalib, Makii
    Millet, Guillaume Y.
    Quaresima, Valentina
    Nosaka, Kazunori
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (01)
  • [42] Electromyographic, cerebral, and muscle hemodynamic responses during intermittent, isometric contractions of the biceps brachii at three submaximal intensities
    Bhambhani, Yagesh
    Fan, Jui-Lin
    Place, Nicolas
    Rodriguez-Falces, Javier
    Kayser, Bengt
    FRONTIERS IN PHYSIOLOGY, 2014, 5
  • [43] Electrical nerve stimulation modulates motor unit activity in contralateral biceps brachii during steady isometric contractions
    Hamilton, Landon D.
    Mani, Diba
    Almuklass, Awad M.
    Davis, Leah A.
    Vieira, Taian
    Botter, Alberto
    Enoka, Roger M.
    JOURNAL OF NEUROPHYSIOLOGY, 2018, 120 (05) : 2603 - 2613
  • [44] Establishment of EMG-Force relationship obtained during Simultaneous Voluntary Contraction of Biceps and Flexor Digitorum Profundus Muscles
    Biswas, Anadi
    Parbat, Debanjan
    Chakraborty, Monisha
    2019 IEEE 5TH INTERNATIONAL CONFERENCE FOR CONVERGENCE IN TECHNOLOGY (I2CT), 2019,
  • [45] Analysis of right arm biceps brachii muscle activity with varying the electrode placement on three male age groups during isometric contractions using a wireless EMG sensor
    Ahamed, Nizam Uddin
    Sundaraj, Kenneth
    Ahmad, R. Badlishah
    Rahman, Matiur
    Islam, Md. Anamul
    INTERNATIONAL SYMPOSIUM ON ROBOTICS AND INTELLIGENT SENSORS 2012 (IRIS 2012), 2012, 41 : 61 - 67
  • [46] Evaluation of the EMG-force relationship of trunk muscles during whole body tilt
    Anders, Christoph
    Brose, Gunther
    Hofmann, Gunther O.
    Scholle, Hans-Christoph
    JOURNAL OF BIOMECHANICS, 2008, 41 (02) : 333 - 339
  • [47] Gender Effects in Surface Electromyographic Activity of the Biceps Brachii Muscle during Prolonged Isometric Contraction
    Ahamed, Nizam Uddin
    bin Md Yusof, Zulkifli
    Alqahtani, Mahdi
    Altwijri, Omar
    Rahman, S. A. M. Matiur
    Sundaraj, Kenneth
    COMPLEX ADAPTIVE SYSTEMS, 2015, 2015, 61 : 448 - 453
  • [48] Analysis of the Effect on Electrode Placement on an Adolescent's Biceps Brachii during Muscle Contractions Using a Wireless EMG Sensor
    Ahamed, Nizam Uddin
    Sundaraj, Kenneth
    Ahmad, R. Badlisha
    Rahman, Matiur
    Islam, Anamul
    Ali, Asraf
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2012, 24 (07) : 609 - 611
  • [49] Filterbank Spectral Estimators for the Analysis of Surface EMG Signals During Isometric Contractions
    Alty, Stephen R.
    Georgakis, Apostolos
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3527 - 3530
  • [50] Reliability of EMG power-spectrum and amplitude of the semitendinosus and biceps femoris muscles during ramp isometric contractions
    Kellis, Eleftherios
    Katis, Athanasios
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (03) : 351 - 358