Surface EMG-force modelling for the biceps brachii and its experimental evaluation during isometric isotonic contractions

被引:14
|
作者
Cao, Hua [1 ]
Boudaoud, Sofiane [2 ]
Marin, Frederic [2 ]
Marque, Catherine [2 ]
机构
[1] HEI, Dept EEA, Lille, France
[2] Univ Technol Compiegne, UMR CNRS Biomecan & Bioingn 7338, Ctr Rech Royallieu, F-60205 Compiegne, France
关键词
sensitivity analysis; motor unit recruitment scheme; muscle force; Monte-Carlo simulations; isometric contractions; biomechanics; modelling; sEMG; UNIT RECRUITMENT STRATEGIES; MOTOR-UNIT; MUSCLE FORCE; ELECTROMYOGRAPHIC SIGNAL; MYOELECTRIC SIGNAL; JOINT MOMENTS; POWER SPECTRA; ELBOW JOINT; FREQUENCY; SIMULATION;
D O I
10.1080/10255842.2013.867952
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The aim of this study was to evaluate a surface electromyography (sEMG) signal and force model for the biceps brachii muscle during isotonic isometric contractions for an experimental set-up as well as for a simulation. The proposed model includes a new rate coding scheme and a new analytical formulation of the muscle force generation. The proposed rate coding scheme supposes varying minimum and peak firing frequencies according to motor unit (MU) type (I or II). Practically, the proposed analytical mechanogram allows us to tune the force contribution of each active MU according to its type and instantaneous firing rate. A subsequent sensitivity analysis using a Monte Carlo simulation allows deducing optimised input parameter ranges that guarantee a realistic behaviour of the proposed model according to two existing criteria and an additional one. In fact, this proposed new criterion evaluates the force generation efficiency according to neural intent. Experiments and simulations, at varying force levels and using the optimised parameter ranges, were performed to evaluate the proposed model. As a result, our study showed that the proposed sEMG-force modelling can emulate the biceps brachii behaviour during isotonic isometric contractions.
引用
收藏
页码:1014 / 1023
页数:10
相关论文
共 50 条
  • [21] Endurance Time Prediction of Biceps Brachii Muscle Using Dimitrov Spectral Index of Surface Electromyogram During Isotonic Contractions
    Lee, Ki Young
    Lee, Sangsik
    Choi, Ahn Ryul
    Choi, Chang-Hyun
    Mun, Joung Hwan
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2011, 12 (04): : 711 - 717
  • [22] Nonlinear Methods on HD-sEMG Signals for Aging Effect Evaluation During Isometric Contractions of the Biceps Brachii
    Ghiatt, Kawtar
    Diab, Ahmad
    Boudaoud, Sofiane
    Kinugawa, Kiyoka
    McPhee, John
    Jiang, Ning
    INTELLIGENT ROBOTICS AND APPLICATIONS (ICIRA 2022), PT IV, 2022, 13458 : 354 - 362
  • [23] Endurance time prediction of biceps brachii muscle using Dimitrov spectral index of surface electromyogram during isotonic contractions
    Ki Young Lee
    Sangsik Lee
    Ahn Ryul Choi
    Chang-Hyun Choi
    Joung Hwan Mun
    International Journal of Precision Engineering and Manufacturing, 2011, 12 : 711 - 717
  • [24] Evaluation of repetitive isometric contractions on the heads of triceps brachii muscle during grip force exercise
    Ali, Md. Asraf
    Sundaraj, Kenneth
    Ahmad, R. Badlishah
    Ahamed, Nizam Uddin
    Islam, Md. Anamul
    Sundaraj, Sebastian
    TECHNOLOGY AND HEALTH CARE, 2014, 22 (04) : 617 - 625
  • [25] Surface EMG signal processing during isometric contractions
    Merletti, R
    LoConte, LR
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1997, 7 (04) : 241 - 250
  • [26] Endurance Capacity of the Biceps Brachii Muscle Using the High-to-Low Ratio between Two Signal Spectral Moments of Surface EMG Signals during Isotonic Contractions
    Lee, Sang-Sik
    Jang, Jee-Hun
    Cho, Chang-Ok
    Kim, Dong-Jun
    Moon, Gun-Pil
    Kim, Buom
    Choi, Ahn-Ryul
    Lee, Ki-Young
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2017, 12 (04) : 1641 - 1648
  • [27] Force-velocity relationship during isometric and isotonic fatiguing contractions
    Devrome, Andrea N.
    MacIntosh, Brian R.
    JOURNAL OF APPLIED PHYSIOLOGY, 2018, 125 (03) : 706 - 714
  • [28] Surface electromyographic dynamics during biceps brachii eccentric and concentric contractions
    Department of Psychology and Behavioral Sciences, Zhejiang University, Hangzhou 310028, China
    不详
    Zhejiang Daxue Xuebao (Gongxue Ban), 2006, 11 (1937-1941):
  • [29] Fatigue analysis of interference EMG signals obtained from biceps brachii during isometric voluntary contraction at various force levels
    Dimitrova, N. A.
    Arabadzhiev, T. I.
    Hogrel, J. -Y.
    Dimitrov, G. V.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2009, 19 (02) : 252 - 258
  • [30] Spectral properties of electromyographic and mechanomyographic signals during isometric ramp and step contractions in biceps brachii
    Qi, Liping
    Wakeling, James M.
    Green, Adam
    Lambrecht, Kirstin
    Ferguson-Pell, Martin
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2011, 21 (01) : 128 - 135