Objective assessment of deformable image registration in radiotherapy - a multi-institution study

被引:1
|
作者
Kashani, R.
Baiter, J.
Kessler, M.
Hub, M.
Dong, L.
Zhang, L.
Xing, L.
Xie, Y.
Hawkes, D.
Schnabel, J.
McClelland, J.
Joshi, S.
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
[2] Deutsch Krebsforschungszentrum, D-6900 Heidelberg, Germany
[3] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
[4] Stanford Univ, Sch Med, Stanford, CA USA
[5] UCL, London, England
[6] Univ Utah, Salt Lake City, UT USA
关键词
D O I
10.1118/1.2761334
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The looming potential of deformable alignment tools to play an integral role in adaptive radiotherapy suggests a need for objective assessment of these complex algorithms. Current studies of accuracy require analytically generated deformations applied to sample image data, or use of contours or bifurcations, with inherent uncertainty as well as potential bias, as these visible features are likely to dominate the local deformation parameters. Method and Materials: A deformable phantom was embedded with 48 small radiopaque markers, placed in regions varying from high contrast to roughly uniform regional intensity, and small to large regional discontinuities in movement. CT volumes of this phantom were acquired in two different deformation states. After manual localization of marker coordinates, images were edited to remove the markers. The resulting image volumes were sent to 4 collaborating institutions, each of which has developed previously published deformable alignment tools routinely in use. Alignments were done, and applied to the list of reference coordinates. The transformed coordinates were compared to the actual marker locations. Results: 5 alignment techniques were tested from the 4 institutions. All algorithms performed generally well, as compared to previous publications. Average errors in predicted location ranged from 1.7–3.9 mm, depending on technique. No algorithm was uniformly accurate across all regions of the phantom, with maximum errors ranging from 5.5 – 15.4 mm. Larger errors were seen in regions near significant shape changes, as well as areas with uniform contrast but large local motion discontinuity. Conclusion: An objective test of deformable alignment is feasible. Reasonable accuracy was achieved, although variable errors in different regions suggest caution in globally accepting the results from deformable alignment. Valuable feedback from investigators is being applied to development of further generations of deformable phantoms for alignment experiments. Sponsored by NIH P01‐CA59827. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2545 / 2545
页数:1
相关论文
共 50 条
  • [41] Applying Multi-Metric Deformable Image Registration for Dose Accumulation in Combined Cervical Cancer Radiotherapy
    Fu, Qi
    Xie, Xin
    Xu, Yingjie
    Zuo, Jing
    Yang, Xi
    Xia, Wenlong
    An, Jusheng
    Huang, Manni
    Yan, Hui
    Dai, Jianrong
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (02):
  • [42] Assessment of Dose Accumulation with Different Deformable Image Registration Algorithms for Image-Guided Radiotherapy of Head and Neck Cancer
    Dogan, N.
    Sleeman, W.
    Asher, D.
    Fatyga, M.
    Schutzer, M.
    Song, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [43] Multi-institution automated image analysis of PTEN protein in prostatic adenocarcinoma
    Faith, DA
    Ertoy-Baydar, D
    Spotler, YS
    Platz, EA
    Rubin, MA
    Ayala, G
    De Marzo, AM
    LABORATORY INVESTIGATION, 2005, 85 : 140A - 140A
  • [44] Multi-institution automated image analysis of PTEN protein in prostatic adenocarcinoma
    Faith, DA
    Ertoy-Baydar, D
    Spolter, YS
    Platz, EA
    Rubin, MA
    Ayala, G
    De Marzo, AM
    MODERN PATHOLOGY, 2005, 18 : 140A - 140A
  • [45] A contour-guided deformable image registration algorithm for adaptive radiotherapy
    Gu, Xuejun
    Dong, Bin
    Wang, Jing
    Yordy, John
    Mell, Loren
    Jia, Xun
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (06): : 1889 - 1901
  • [46] Accuracy of deformable image registration for contour propagation in adaptive lung radiotherapy
    Nicholas Hardcastle
    Wouter van Elmpt
    Dirk De Ruysscher
    Karl Bzdusek
    Wolfgang A Tomé
    Radiation Oncology, 8
  • [47] Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints
    Koenig, Lars
    Derksen, Alexander
    Papenberg, Nils
    Haas, Benjamin
    RADIATION ONCOLOGY, 2016, 11
  • [48] ROI constrained deformable image registration for on-line adaptive radiotherapy
    Chen, M.
    Lu, W.
    Chen, Q.
    Ruchala, K.
    Olivera, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S727 - S728
  • [49] Tools and recommendations for commissioning and quality assurance of deformable image registration in radiotherapy
    Bosma, Lando
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S124 - S124
  • [50] Accuracy of deformable image registration for contour propagation in adaptive lung radiotherapy
    Hardcastle, Nicholas
    van Elmpt, Wouter
    De Ruysscher, Dirk
    Bzdusek, Karl
    Tome, Wolfgang A.
    RADIATION ONCOLOGY, 2013, 8