Objective assessment of deformable image registration in radiotherapy - a multi-institution study

被引:1
|
作者
Kashani, R.
Baiter, J.
Kessler, M.
Hub, M.
Dong, L.
Zhang, L.
Xing, L.
Xie, Y.
Hawkes, D.
Schnabel, J.
McClelland, J.
Joshi, S.
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
[2] Deutsch Krebsforschungszentrum, D-6900 Heidelberg, Germany
[3] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
[4] Stanford Univ, Sch Med, Stanford, CA USA
[5] UCL, London, England
[6] Univ Utah, Salt Lake City, UT USA
关键词
D O I
10.1118/1.2761334
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The looming potential of deformable alignment tools to play an integral role in adaptive radiotherapy suggests a need for objective assessment of these complex algorithms. Current studies of accuracy require analytically generated deformations applied to sample image data, or use of contours or bifurcations, with inherent uncertainty as well as potential bias, as these visible features are likely to dominate the local deformation parameters. Method and Materials: A deformable phantom was embedded with 48 small radiopaque markers, placed in regions varying from high contrast to roughly uniform regional intensity, and small to large regional discontinuities in movement. CT volumes of this phantom were acquired in two different deformation states. After manual localization of marker coordinates, images were edited to remove the markers. The resulting image volumes were sent to 4 collaborating institutions, each of which has developed previously published deformable alignment tools routinely in use. Alignments were done, and applied to the list of reference coordinates. The transformed coordinates were compared to the actual marker locations. Results: 5 alignment techniques were tested from the 4 institutions. All algorithms performed generally well, as compared to previous publications. Average errors in predicted location ranged from 1.7–3.9 mm, depending on technique. No algorithm was uniformly accurate across all regions of the phantom, with maximum errors ranging from 5.5 – 15.4 mm. Larger errors were seen in regions near significant shape changes, as well as areas with uniform contrast but large local motion discontinuity. Conclusion: An objective test of deformable alignment is feasible. Reasonable accuracy was achieved, although variable errors in different regions suggest caution in globally accepting the results from deformable alignment. Valuable feedback from investigators is being applied to development of further generations of deformable phantoms for alignment experiments. Sponsored by NIH P01‐CA59827. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2545 / 2545
页数:1
相关论文
共 50 条
  • [31] MULTI-INSTITUTION VALIDATION OF AN EMERGENCY ULTRASOUND IMAGE RATING SCALE-A PILOT STUDY
    Lam, Samuel H. F.
    Bailitz, John
    Blehar, David
    Becker, Brent A.
    Hoffmann, Beatrice
    Liteplo, Andrew S.
    Rajan, Kumar B.
    Lambert, Michael
    JOURNAL OF EMERGENCY MEDICINE, 2015, 49 (01): : 32 - 39
  • [32] A framework for deformable image registration validation in radiotherapy clinical applications
    Varadhan, Raj
    Karangelis, Grigorios
    Krishnan, Karthik
    Hui, Susanta
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01): : 192 - 213
  • [33] Longitudinal Unsupervised Deformable Image Registration Network for Adaptive Radiotherapy
    Lee, D.
    Hu, Y.
    Alam, S.
    Cervino, L.
    Zhang, P.
    MEDICAL PHYSICS, 2022, 49 (06) : E605 - E605
  • [34] Diversifying Multi-Objective Gradient Techniques and their Role in Hybrid Multi-Objective Evolutionary Algorithms for Deformable Medical Image Registration
    Pirpinia, Kleopatra
    Alderliesten, Tanja
    Sonke, Jan-Jakob
    van Herk, Marcel
    Bosman, Peter A. N.
    GECCO'15: PROCEEDINGS OF THE 2015 GENETIC AND EVOLUTIONARY COMPUTATION CONFERENCE, 2015, : 1255 - 1262
  • [35] CHED 142-SALG and POGIL: A multi-institution assessment
    Bressette, Andrew R.
    Straumanis, Andrei
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 232
  • [36] Multi-Modal Deformable Medical Image Registration
    Fookes, Clinton
    Sridharan, Sridha
    ICSPCS: 2ND INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATION SYSTEMS, PROCEEDINGS, 2008, : 661 - 669
  • [37] Motivation Filtering on a Multi-Institution Assessment of General College Outcomes
    Steedle, Jeffrey T.
    APPLIED MEASUREMENT IN EDUCATION, 2014, 27 (01) : 58 - 76
  • [38] Incremental Gaussian Model-Building in Multi-Objective EDAs with an Application to Deformable Image Registration
    Bosman, Peter A. N.
    Alderliesten, Tanja
    PROCEEDINGS OF THE FOURTEENTH INTERNATIONAL CONFERENCE ON GENETIC AND EVOLUTIONARY COMPUTATION CONFERENCE, 2012, : 241 - 248
  • [39] Assessment Of A Commercially Available Algorithm For Deformable Image Registration
    De La Casa, M. A.
    Zucca, D.
    Garcia, J.
    Marti, J.
    Fernandez-Leton, P.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : E560 - E560
  • [40] A multi-resolution strategy for a multi-objective deformable image registration framework that accommodates large anatomical differences
    Alderliesten, Tanja
    Bosman, Peter A. N.
    Sonke, Jan-Jakob
    Bel, Arjan
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034