Comparison of the morphological and biomechanical characteristics of keratoconus, forme fruste keratoconus, and normal corneas

被引:20
|
作者
Guo, Li-Li [1 ]
Tian, Lei [1 ,2 ,3 ]
Cao, Kai [1 ]
Li, Yu-Xin [1 ]
Li, Na [1 ]
Yang, Wei-Qiang [1 ]
Jie, Ying [1 ]
机构
[1] Capital Med Univ, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Hosp, Beijing Inst Ophthalmol,Beijing Tongren Eye Ctr, Beijing, Peoples R China
[2] Beihang Univ, Beijing Adv Innovat Ctr Big Data Based Precis Med, Beijing, Peoples R China
[3] Capital Med Univ, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
keratoconus; forme fruste keratoconus; corneal morphology; corneal biomechanics; Corvis ST;
D O I
10.1080/08820538.2021.1896752
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To explore the feasibility of corneal morphological and biomechanical parameters for keratoconus and forme fruste keratoconus diagnosis. Methods: This case-control study included a total of 517 eyes from 408 keratoconus patients (KC group), 83 eyes from 83 forme fruste keratoconus patients (FFKC group), and 158 eyes from 158 patients with normal corneas (NL group). All subjects underwent routine ophthalmologic examinations. Pentacam and Corneal Visualization Scheimpflug Technology (Corvis ST) were used to obtain corneal morphological and biomechanical parameters. Differences between groups were compared using receiver operating characteristic (ROC) curve analysis. Results: ROC analysis showed that all corneal morphological parameters and most biomechanical parameters distinguished KC from NL, with an area under the curve (AUC) greater than 0.80, of which Belin-Ambrosio enhanced ectasia total deviation index (BAD-D) and tomographic and biomechanical index (TBI) were most efficient. The AUC for distinguishing KC from NL of the BAD-D was 0.989 and the TBI was 0.993, which were not statistically significant (DeLong et al., P= .232). The BAD-D cut-off point of 1.595 provided 95.9% sensitivity for distinguishing KC from NL with 100% specificity. The TBI cut-off point of 0.515 provided 96.7% sensitivity for distinguishing KC from NL with 100% specificity. The ability of other parameters to distinguish KC from NL was lower than that of BAD and TBI. Except for central astigmatism from the anterior corneal surface (AstigF), the AUC that distinguished FFKC from NL was 0.862. The AstigF cut-off point of 4.65 provided 73.5% sensitivity for distinguishing FFKC from NL with 99.3% specificity. Other parameters distinguished FFKC from NL with low efficiency. Among them, the AUC for distinguishing FFKC from NL of the TBI was 0.722, whose cut-off point of 0.273 provided 55.4% sensitivity for distinguishing KC from NL with 79.7% specificity. Conclusion: BAD-D and TBI have the highest efficiency, sensitivity, and specificity for distinguishing KC from NL. Except for AstigF, other corneal morphological and biomechanical parameters have a relatively low ability to distinguish FFKC from NL.
引用
收藏
页码:671 / 678
页数:8
相关论文
共 50 条
  • [31] A COMPARISON OF PROTEOGLYCAN ARRANGEMENT IN NORMAL AND KERATOCONUS HUMAN CORNEAS
    FULLWOOD, NJ
    MEEK, KM
    MALIK, NS
    TUFT, SJ
    BIOCHEMICAL SOCIETY TRANSACTIONS, 1990, 18 (05) : 961 - 962
  • [32] Topography-guided surface ablation for forme fruste keratoconus
    Koller, Tobias
    Iseli, Hans Peter
    Donitzky, Christof
    Papadopoulos, Nikolaos
    Seiler, Theo
    OPHTHALMOLOGY, 2006, 113 (12) : 2198 - 2202
  • [33] Evaluation of CorvisST biomechanical parameters and anterior segment optical coherence tomography for diagnosing forme fruste keratoconus
    Shiga, Suguru
    Kojima, Takashi
    Nishida, Tomoya
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    ACTA OPHTHALMOLOGICA, 2021, 99 (06) : 644 - 651
  • [34] Diagnostic Value of Corneal Epithelial and Stromal Thickness Distribution Profiles in Forme Fruste Keratoconus and Subclinical Keratoconus
    Toprak, Ibrahim
    Vega, Alfredo
    Alio del Barrio, Jorge L.
    Espla, Elias
    Cavas, Francisco
    Alio, Jorge L.
    CORNEA, 2021, 40 (01) : 61 - 72
  • [35] Optical quality assessment in normal and forme fruste keratoconus eyes with a double-pass system: a comparison and variability study
    Ye, Cong
    Ng, Paul Ka-Fai
    Jhanji, Vishal
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (11) : 1478 - 1483
  • [36] THE STRUCTURE OF NORMAL AND KERATOCONUS HUMAN CORNEAS
    MEEK, KM
    ELLIOTT, GF
    GYI, TJ
    WALL, RS
    OPHTHALMIC RESEARCH, 1987, 19 (01) : 6 - 7
  • [37] Brillouin Spectroscopy of Normal and Keratoconus Corneas
    Seiler, Theo G.
    Shao, Peng
    Eltony, Amira
    Seiler, Theo
    Yun, Seok-Hyun
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 202 : 118 - 125
  • [38] Multifocal Toric Intraocular Lens Implantation for Forme Fruste and Stable Keratoconus
    Montano, Margarita
    Lopez-Dorantes, Karla P.
    Ramirez-Miranda, Arturo
    Graue-Hernandez, Enrique O.
    Navas, Alejandro
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (04) : 282 - 285
  • [39] Enhanced Combined Tomography and Biomechanics Data for Distinguishing Forme Fruste Keratoconus
    Luz, Allan
    Lopes, Bernardo
    Hallahan, Katie M.
    Valbon, Bruno
    Ramos, Isaac
    Faria-Correia, Fernando
    Schor, Paulo
    Dupps, William J., Jr.
    Ambrosio, Renato, Jr.
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (07) : 479 - +
  • [40] Evidence of corneal ectasia susceptibility: a new definition of forme fruste keratoconus
    Koh, Shizuka
    Ambrosio, Renato, Jr.
    Maeda, Naoyuki
    Nishida, Kohji
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (11): : 1570 - 1572