Adsorptive stripping voltammetric determination of erythromycin at a pretreated glassy carbon electrode

被引:45
|
作者
Wang, HS [1 ]
Zhang, AM [1 ]
Cui, H [1 ]
Liu, DJ [1 ]
Liu, RM [1 ]
机构
[1] Liaocheng Teachers Univ, Dept Chem, Liaocheng 252059, Peoples R China
关键词
adsorptive stripping voltammetry; glass carbon electrode; erythromycin determination; urine;
D O I
10.1016/S0026-265X(99)00019-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The voltammetric behavior of the antibiotic erythromycin and its determination was described. Erythromycin was found to give one oxidative peak by cyclic voltammetry at a glassy carbon electrode which was electrochemically treated in 0.025 mol l(-1) NH3-NH4Cl (pH 9.0) solution for 6 min. The reverse cyclic voltammograms did not show any reductive peaks. An adsorptive stripping voltammetric method for the determination of the antibiotic erythromycin at an electrochemically pretreated glassy carbon electrode has been developed. Erythromycin was accumulated in NH3-NH4Cl (pH 9.0) medium at the potential of +0.2 V (vs. Ag/AgCl electrode) for a certain time and then determined by second differential anodic stripping voltammetry. The second-order differential peak current (e ") at +0.86 V, at a scan rate of 445 mV s(-1), was a linear function of concentration of erythromycin in the range 2.5 x 10(-8) similar to 3.5 x 10(-7) mol l(-1) (90 s preconcentration) and 1.2 x 10(-8) similar to 2.5 x 10(-7) mol l(-1) (120 s preconcentration), and the detection limit was 5.0 x 10(-9) mol l(-1) (4 min preconcentration). The method has been applied to the determination of erythromycin in commercial tablets and spiked urine samples with satisfactory results. The relative standard deviation (n = 5) was less than 4.5%. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:67 / 71
页数:5
相关论文
共 50 条
  • [31] ADSORPTIVE STRIPPING VOLTAMMETRIC DETERMINATION OF ULTRATRACE CONCENTRATIONS OF MOLYBDENUM IN BIOLOGICAL AND ENVIRONMENTAL MATERIALS ON A GLASSY-CARBON MERCURY FILM ELECTRODE
    ADELOJU, SBO
    PABLO, F
    ELECTROANALYSIS, 1995, 7 (05) : 476 - 482
  • [32] Multiwalled Carbon Nanotubes Modified Electrode as a Sensor for Adsorptive Stripping Voltammetric Determination of Hydrochlorothiazide
    Rezaei, Behzad
    Damiri, Sajjad
    IEEE SENSORS JOURNAL, 2008, 8 (9-10) : 1523 - 1529
  • [33] Adsorptive stripping voltammetric detection of single-stranded DNA at electrochemically modified glassy carbon electrode
    Wang, HS
    Ju, HX
    Chen, HY
    ELECTROANALYSIS, 2002, 14 (23) : 1615 - 1620
  • [34] Cysteine determination via adsorptive stripping voltammetry using a bare glassy carbon electrode
    Areias, Madalena C. C.
    Shimizu, Kenichi
    Compton, Richard G.
    ANALYST, 2016, 141 (19) : 5563 - 5570
  • [35] Adsorptive stripping voltammetry of nickel at a bare glassy carbon electrode
    Rutyna, Iwona
    Korolczuk, Mieczyslaw
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (12) : 1253 - 1260
  • [36] Poly(alizarin red S) modified glassy carbon electrode for square wave adsorptive stripping voltammetric determination of metronidazole in tablet formulation
    Dawit, Mulugeta
    Turbale, Mahilet
    Moges, Amsalu
    Amare, Meareg
    PLOS ONE, 2020, 15 (12):
  • [37] Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes
    Khodadadian, Mehdi
    Jalili, Ronak
    Bahrami, Mohammad Taher
    Bahrami, Gholamreza
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2017, 16 (04): : 1312 - 1319
  • [38] Voltammetric determination of niclosamide at a glassy carbon electrode
    Alemu, H
    Wagana, P
    Tseki, PF
    ANALYST, 2002, 127 (01) : 129 - 134
  • [39] VOLTAMMETRIC DETERMINATION OF NEPTUNIUM AT GLASSY CARBON ELECTRODE
    PLOCK, CE
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1968, 18 (03): : 289 - &
  • [40] Voltammetric determination of paracetamol on the glassy carbon electrode
    毕淑云
    王桂芬
    朴元哲
    王大力
    殷晓萍
    延边大学学报(自然科学版), 2000, (02) : 110 - 112