Conducted Electrical Weapon Use by Law Enforcement: An Evaluation of Safety and Injury

被引:53
|
作者
Strote, Jared [1 ]
Walsh, Mimi [2 ]
Angelidis, Matthew [3 ]
Basta, Amaya [4 ]
Hutson, H. Range [5 ]
机构
[1] Univ Washington, Div Emergency Med, Seattle, WA 98195 USA
[2] Seattle Police Dept, Seattle, WA USA
[3] Madigan Army Med Ctr, Dept Emergency Med, Ft Lewis, WA USA
[4] Univ Washington, Sch Med, Seattle, WA 98195 USA
[5] Harvard Univ, Sch Med, Dept Emergency Med, Boston, MA USA
关键词
Conducted electrical weapons; Law enforcement; Taser; SUDDEN-DEATH; EXCITED DELIRIUM; PRONE RESTRAINT; MEDICAL SAFETY; TASER; POLICE; POSITIONS; CUSTODY; FORCE;
D O I
10.1097/TA.0b013e3181b28b78
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Controversy persists over the safety of conducted electrical weapons (CEWs), which are increasingly used by law enforcement agencies around the world. The purpose of this study was to examine injury patterns and physiologic conditions after CEW use under real life conditions. Methods: A retrospective, cohort design was used, examining all CEW uses by one police department during a 6-year period. Data were collected from use-of-force forms and medical records and included conditions surrounding the use of force, medical histories, and data from emergency department evaluations and hospital admissions. Results: Of 1,101 individuals subjected to (Taser M26 and X26) CEW use during the study period, 92.6% were male, the average body mass index was 26.2, and the age range was 9 to 73 years. Of the 886 (80.5%) with medical records, 46.8% had a psychiatric history and 72.9% had a substance abuse history. Emergency department (ED) evaluations occurred for 295 (26.8%) incidents. Of chief complaints, 41.7% were trauma related, 26.8% were for altered mental status, and 21.7% were for psychiatric evaluation. On presentation, 17.6% had a pulse >120, 1.7% were febrile, and 30.9% were altered; 1.4% met criteria associated with "excited delirium." When laboratory workup occurred, 70.6% had positive urine toxicology and 44.8% had positive alcohol levels. Troponin I was positive for one patient. Other laboratory abnormalities were rare, although extensive evaluations were infrequently done. Admission occurred in 24.4% of ED presentations (6.5% of all subjects); of discharge diagnoses for these patients, 59.7% were psychiatric, 22.2% were for unrelated trauma, 11.1% were for restraint-related trauma, and 6.9% were for unrelated medical diagnoses. No patients died. Conclusions: Significant injuries related to 6 years of law enforcement CEW use in one city were rare. A large percentage of those subjected to CEW use had diagnoses of substance abuse and/or psychiatric conditions. Most admissions after CEW use were unrelated to law enforcement restraint.
引用
收藏
页码:1239 / 1246
页数:8
相关论文
共 50 条
  • [11] Predictors of weapon use in domestic violence incidents reported to law enforcement
    Kernsmith, Poco
    Craun, Sarah W.
    JOURNAL OF FAMILY VIOLENCE, 2008, 23 (07) : 589 - 596
  • [12] Predictors of Weapon Use in Domestic Violence Incidents Reported to Law Enforcement
    Poco Kernsmith
    Sarah W. Craun
    Journal of Family Violence, 2008, 23 : 589 - 596
  • [13] INTRODUCTION OF THE CONDUCTED ELECTRICAL WEAPON INTO A HOSPITAL SETTING
    Ho, Jeffrey D.
    Clinton, Joseph E.
    Lappe, Mark A.
    Heegaard, William G.
    Williams, Martin F.
    Miner, James R.
    JOURNAL OF EMERGENCY MEDICINE, 2011, 41 (03): : 317 - 323
  • [14] The Physiologic effects of a conducted electrical weapon in swine
    Esquivel, Amanda O.
    Dawe, Elizabeth J.
    Sala-Mercado, Javier A.
    Hammond, Robert L.
    Bir, Cynthia A.
    ANNALS OF EMERGENCY MEDICINE, 2007, 50 (05) : 576 - 583
  • [15] Safety belt use by law enforcement officers on reality television: A missed opportunity for injury prevention?
    Cowan, John A., Jr.
    Jones, Bradley
    Ho, Helen
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 61 (04): : 1001 - 1004
  • [16] Evaluation of Law Enforcement Agency Injury Severity Assessments
    Burdett, Beau
    Bill, Andrea
    Noyce, David
    TRANSPORTATION RESEARCH RECORD, 2022, 2676 (09) : 246 - 255
  • [17] Physiological effects of a conducted electrical weapon on human subjects
    Vilke, Gary M.
    Sloane, Christian M.
    Bouton, Katie D.
    Kolkhorst, Fred W.
    Levine, Saul D.
    Neuman, Tom S.
    Castillo, Edward M.
    Chan, Theodore C.
    ANNALS OF EMERGENCY MEDICINE, 2007, 50 (05) : 569 - 575
  • [18] Physiological responses in reindeer to the application of a conducted electrical weapon
    Lieske, Camilla L.
    Beckmen, Kimberlee B.
    Lewis, Larry L.
    HUMAN-WILDLIFE INTERACTIONS, 2018, 12 (02): : 160 - 170
  • [19] Myocardial infarction after conducted electrical weapon shock
    Ben Ahmed, H.
    Bouzouita, K.
    Selmi, K.
    Chelli, M.
    Mokaddem, A.
    Ben Ameur, Y.
    Boujnah, M. R.
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 2013, 62 (02): : 124 - 126
  • [20] Conductive electrical devices: A prospective, population-based study of the medical safety of law enforcement use
    Eastman, Alexander L.
    Metzger, Jeffery C.
    Pepe, Paul E.
    Benitez, Fernando L.
    Decker, Sgt. James
    Rinnert, Kathy J.
    Field, Craig A.
    Friese, Randall S.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (06): : 1567 - 1572