The Physiologic effects of a conducted electrical weapon in swine

被引:14
|
作者
Esquivel, Amanda O.
Dawe, Elizabeth J.
Sala-Mercado, Javier A.
Hammond, Robert L.
Bir, Cynthia A.
机构
[1] Wayne State Univ, Coll Engn, Detroit, MI USA
[2] Wayne State Univ, Coll Med, Surg Res Serv, Sch Med, Detroit, MI USA
关键词
D O I
10.1016/j.annemergmed.2007.05.003
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: By using an animal model, we determine whether repeated exposures to a conducted electrical weapon could have physiologic consequences. Methods: Exposures to the Stinger S-400 conducted electrical weapon were applied to 10 healthy, anesthetized, Yorkshire-cross, male swine by attaching probes from the cartridge to the sternal notch and anterolateral thorax at a distance of 21.5 cm. The standard pulse generated by the Stinger S-400 during the normal application was applied 20 times during 31 minutes. To evaluate the health effects of the exposures, key physiologic characteristics were evaluated, including arterial pH, PCO2, PO2, blood lactate, cardiac output, ECG, pulse rate, mean arterial pressure, central venous pressure, pulmonary artery pressure and airway pressure, and the cardiac marker troponin l. Results: There were notable changes in pH, PCO2, blood lactate, cardiac output, and mean arterial pressure after 1 or more sets of exposures, all of which normalized during the next few hours. Troponin l PO2, pulse rate, mean arterial pressure, central venous pressure, pulmonary artery pressure, and airway pressure did not change markedly during or after the shocks. Three premature ventricular contractions occurred in one animal; all other ECG results were normal. Conclusion: Repeated exposures to a conducted electrical weapon result in respiratory acidosis, metabolic vasodilation, and an increase in blood lactate level. These effects were transient in this study, with full recovery by 4 hours postexposure. The Stinger S-400 appears to have no serious adverse physiologic effects on healthy, anesthetized swine.
引用
收藏
页码:576 / 583
页数:8
相关论文
共 50 条
  • [1] Cardiovascular and Physiologic effects of conducted electrical weapon discharge in resting adults
    Ho, Jeffrey D.
    Miner, James R.
    Lakireddy, Dhanunjaya R.
    Bultman, Laura L.
    Heegaard, William G.
    ACADEMIC EMERGENCY MEDICINE, 2006, 13 (06) : 589 - 595
  • [2] PHYSIOLOGIC EFFECTS OF A NEW-GENERATION CONDUCTED ELECTRICAL WEAPON ON HUMAN VOLUNTEERS
    Ho, Jeffrey D.
    Dawes, Donald M.
    Chang, Richard J.
    Nelson, Rebecca S.
    Miner, James R.
    JOURNAL OF EMERGENCY MEDICINE, 2014, 46 (03): : 428 - 434
  • [3] The physiologic effects of a new generation conducted electrical weapon on human volunteers at rest
    Ho, Jeffrey D.
    Dawes, Donald M.
    Kunz, Sebastian N.
    Klein, Lauren R.
    Driver, Brian E.
    DeVries, Paige A.
    Jones, Gregg A.
    Stang, Jamie L.
    FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2020, 16 (03) : 406 - 414
  • [4] The physiologic effects of a new generation conducted electrical weapon on human volunteers at rest
    Jeffrey D. Ho
    Donald M. Dawes
    Sebastian N. Kunz
    Lauren R. Klein
    Brian E. Driver
    Paige A. DeVries
    Gregg A. Jones
    Jamie L. Stang
    Forensic Science, Medicine and Pathology, 2020, 16 : 406 - 414
  • [5] Physiologic effects of prolonged conducted electrical weapon discharge in ethanol-intoxicated adults
    Moscati, Ronald
    Ho, Jeffrey D.
    Dawes, Donald M.
    Miner, James R.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2010, 28 (05): : 582 - 587
  • [6] Physiological effects of a conducted electrical weapon on human subjects
    Vilke, Gary M.
    Sloane, Christian M.
    Bouton, Katie D.
    Kolkhorst, Fred W.
    Levine, Saul D.
    Neuman, Tom S.
    Castillo, Edward M.
    Chan, Theodore C.
    ANNALS OF EMERGENCY MEDICINE, 2007, 50 (05) : 569 - 575
  • [7] Cardiovascular effects of SPARK conducted electrical weapon in healthy subjects
    Scherr, Carlos
    de Carvalho, Antonio Carlos
    Belem, Luciano Juaaba
    Loyola, Luiz Henrique
    Guerra, Renata Leborato
    Blanco, Fernanda
    Mangia, Claudio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 225 : 123 - 127
  • [8] Human cardiovascular effects of a new generation conducted electrical weapon
    Ho, Jeffrey D.
    Dawes, Donald M.
    Reardon, Robert F.
    Strote, Seth R.
    Kunz, Sebastian N.
    Nelson, Rebecca S.
    Lundin, Erik J.
    Orozco, Benjamin S.
    Miner, James R.
    FORENSIC SCIENCE INTERNATIONAL, 2011, 204 (1-3) : 50 - 57
  • [9] Civilian use of a conducted electrical weapon
    Strote, Jared
    Maher, Patrick
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (04): : 606.e1 - 606.e2
  • [10] Physiologic Changes with an Exposure to a New Concept Conducted Electrical Weapon (T10™) in Human Volunteers
    Dawes D.M.
    Ho J.D.
    Kunz S.N.
    Kuo J.
    Knack S.K.
    Human Factors and Mechanical Engineering for Defense and Safety, 8 (1):