Implementation of free breathing respiratory amplitude-gated treatments

被引:6
|
作者
Hickling, Susannah V. [1 ]
Veres, Andrew J. [1 ]
Moseley, Douglas J. [1 ]
Grams, Michael P. [1 ]
机构
[1] Mayo Clin, Dept Radiat Oncol, Rochester, MN 55905 USA
来源
关键词
4-DIMENSIONAL COMPUTED-TOMOGRAPHY; INDUCED TUMOR MOTION; QUALITY-ASSURANCE; LUNG; RADIOTHERAPY; 4DCT;
D O I
10.1002/acm2.13253
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this study was to provide guidance in developing and implementing a process for the accurate delivery of free breathing respiratory amplitude-gated treatments. Methods A phase-based 4DCT scan is acquired at time of simulation and motion is evaluated to determine the exhale phases that minimize respiratory motion to an acceptable level. A phase subset average CT is then generated for treatment planning and a tracking structure is contoured to indicate the location of the target or a suitable surrogate over the planning phases. Prior to treatment delivery, a 4DCBCT is acquired and a phase subset average is created to coincide with the planning phases for an initial match to the planning CT. Fluoroscopic imaging is then used to set amplitude gate thresholds corresponding to when the target or surrogate is in the tracking structure. The final imaging prior to treatment is an amplitude-gated CBCT to verify both the amplitude gate thresholds and patient positioning. An amplitude-gated treatment is then delivered. This technique was commissioned using an in-house lung motion phantom and film measurements of a simple two-field 3D plan. Results The accuracy of 4DCBCT motion and target position measurements were validated relative to 4DCT imaging. End to end testing showed strong agreement between planned and film measured dose distributions. Robustness to interuser variability and changes in respiratory motion were demonstrated through film measurements. Conclusions The developed workflow utilizes 4DCBCT, respiratory-correlated fluoroscopy, and gated CBCT imaging in an efficient and sequential process to ensure the accurate delivery of free breathing respiratory-gated treatments.
引用
收藏
页码:119 / 129
页数:11
相关论文
共 50 条
  • [21] The clinical implementation of respiratory gated intensity modulated radiotherapy
    Keall, P
    Vedam, S
    George, R
    Siebers, J
    Chung, T
    LUNG CANCER, 2005, 49 : S100 - S100
  • [22] Effect of breathing irregularities on the quantitative accuracy of respiratory gated PET/CT
    Teo, Boon-Keng
    Saboury, Babak
    Scheuermann, Joshua
    Torigian, Drew
    Karp, Joel
    Alavi, Abass
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [23] The effect of breathing irregularities on quantitative accuracy of respiratory gated PET/CT
    Teo, Boon-Keng
    Saboury, Babak
    Munbodh, Reshma
    Scheuermann, Joshua
    Torigian, Drew A.
    Zaidi, Habib
    Alavi, Abass
    MEDICAL PHYSICS, 2012, 39 (12) : 7390 - 7397
  • [24] Clinical experience using respiratory gated radiation therapy: Comparison of free-breathing and breath-hold techniques
    Berson, AM
    Emery, R
    Rodriguez, L
    Richards, GM
    Ng, T
    Sanghavi, S
    Barsa, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (02): : 419 - 426
  • [25] Simultaneous assessment of lung morphology and respiratory motion in retrospectively gated in-vivo microCT of free breathing anesthetized mice
    Dullin, Christian
    Svetlove, Angelika
    Zschuntzsch, Jana
    Alves, Frauke
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [26] Feasibility of Respiratory-gated High-pitch Spiral CT: Free-breathing Inspiratory Image Quality
    Lell, Michael M.
    Scharf, Michael
    Eller, Achim
    Wuest, Wolfgang
    Allmendinger, Thomas
    Fuchs, Florian
    Achenbach, Stephan
    Uder, Michael
    May, Matthias S.
    ACADEMIC RADIOLOGY, 2016, 23 (04) : 406 - 412
  • [27] Simultaneous assessment of lung morphology and respiratory motion in retrospectively gated in-vivo microCT of free breathing anesthetized mice
    Christian Dullin
    Angelika Svetlove
    Jana Zschüntzsch
    Frauke Alves
    Scientific Reports, 12
  • [28] Optimization of a retrospective technique for respiratory-gated high speed micro-CT of free-breathing rodents
    Ford, Nancy L.
    Wheatley, Andrew R.
    Holdsworth, David W.
    Drangova, Maria
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (19): : 5749 - 5769
  • [29] Reduction of Matching Errors Due to Variations of Breathing Patterns in Gated Breast Treatments
    Van den Heuvel, F.
    Petillion, S.
    Crijns, W.
    De Kerf, G.
    Haustermans, K.
    Sweldens, C.
    Weltens, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [30] Relationship of uncertainty due to respiratory motion with amplitude in SBRT treatments
    Garcia Ruiz-Zorrilla, J.
    De la Casa de Julian, M. A.
    de Acilu Laa, P. Garcia
    Hernando Requejo, O.
    Rubio Rodriguez, C.
    Marti Asenjo, J.
    Fernandez Leton, P.
    Zucca Aparicio, D.
    Perez Moreno, J. M.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1073 - S1073