Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion

被引:66
|
作者
Johnson, GH [1 ]
Chellis, KD [1 ]
Gordon, GE [1 ]
Lepe, X [1 ]
机构
[1] Univ Washington, Dept Restorat Dent, Sch Dent, Seattle, WA 98195 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 1998年 / 79卷 / 04期
关键词
D O I
10.1016/S0022-3913(98)70160-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Because irreversible hydrocolloid impressions imbibe blood and saliva, immersion rather than spray disinfection map be more effective. Polyether has been shown to be dimensionally sensitive to immersion disinfection. Purpose. The aim of this study was to determine whether irreversible hydrocolloid and polyether impressions could be disinfected by immersion without sacrificing accuracy and surface quality. Material and methods. Impressions were made of a master mandibular arch containing a crown preparation. Changes between the master and working casts were assessed. Irreversible hydrocolloids (Jeltrate; Palgaflex), a polyether (Impregum F), and an addition silicone (President) were used. Disinfectants were an iodophor (Biocide), a glyoxal glutaraldehyde (Impresept de), and a phenol glutaraldehyde (Sporicidin). The control was without disinfection. Casts were formed in Type IV gypsum. The roughness of working dies was also recorded and an analysis of variance was used for statistical evaluation Results. Casts from disinfected irreversible hydrocolloid and elastomeric impressions maintained accuracy for anteroposterior and cross arch dimensions where differences from the master was less than 0.1%. Buccolingual and mesiodistal dimensions of working dies (disinfected and control) were 6 to 8 mu m larger than the master for addition silicones and 11 to 16 mu m for polyethers. The occlusogingival dimension of dies for control and disinfected polyether was 9 mu m longer than the master compared with -3 mu m for addition silicone. The range of mean surface roughness of working dies made from irreversible hydrocolloids was 1.4 to 1.7 mu m and ranged from 0.5 to 0.7 mu m for elastomeric impressions. Conclusion. Immersion disinfection of Jeltrate material with iodophor and Palgaflex material with glyoxal glutaraldehyde produced casts and dies as accurate as the control. Control and disinfected elastomeric impression produced dies as clinically accurate and smooth as the master. Disinfection of irreversible hydrocolloid impressions with the glyoxal and phenol glutaraldehyde produced a surface smoother than controls.
引用
收藏
页码:446 / 453
页数:8
相关论文
共 44 条
  • [21] Effect of the humidifier storage time on the dimensional stability of irreversible hydrocolloid moulds.
    Sampaio, CAF
    Couto, MP
    Pardal, AF
    Brandao, AJ
    Miranda, MS
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 244 - 244
  • [22] DIMENSIONAL STABILITY AND SURFACE DETAIL REPRODUCTION OF SEVERAL IMPRESSION MATERIALS
    WALLACE, SW
    EAMES, WB
    PRICE, WR
    GASPAR, JD
    JOURNAL OF DENTAL RESEARCH, 1976, 55 : B93 - B93
  • [23] Comparison of dimensional stability of elastomeric impression after immersion disinfection.
    Habib, C
    Smith, C
    Kugel, G
    Aboushala, A
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 357 - 357
  • [24] EFFECT OF WARMED IMMERSION DISINFECTANTS ON THE DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS
    DRENNON, DG
    GABEL, WP
    JOURNAL OF DENTAL RESEARCH, 1990, 69 : 368 - 368
  • [25] Thermal and PH changes, and dimensional stability in irreversible hydrocolloid impression material during setting
    Bayindir, F
    Yanikoglu, N
    Duymus, Z
    DENTAL MATERIALS JOURNAL, 2002, 21 (02) : 200 - 209
  • [26] DIMENSIONAL STABILITY OF IRREVERSIBLE HYDROCOLLOID IMPRESSION MATERIALS AS A FUNCTION OF POURING TIME: A SYSTEMATIC REVIEW
    Nassar, Usama
    Aziz, Tehnia
    Flores-Mir, Carlos
    JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (02): : 126 - 133
  • [27] Evaluation of dimensional stability, compressive resistance, and detail reproduction of thermoplastic resin (BDIMPRESS), elastomeric and composite bite registration material: An in vitro study
    Koppolu, Sai
    Manoharan, P. S.
    Rajkumar, E.
    Ezhumalai, G.
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2023, 23 (01) : 65 - 70
  • [28] Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions
    Mahalakshmi, A. S.
    Jeyapalan, Vidhya
    Mahadevan, Vallabh
    Krishnan, Chitra Shankar
    Azhagarasan, N. S.
    Ramakrishnan, Hariharan
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2019, 19 (01): : 33 - 41
  • [29] Influence of opacifiers on dimensional stability and detail reproduction of maxillofacial silicone elastomer
    Goiato, Marcelo C.
    Haddad, Marcela F.
    Sinhoreti, Mario A. C.
    dos Santos, Daniela M.
    Pesqueira, Aldieris A.
    Moreno, Amalia
    BIOMEDICAL ENGINEERING ONLINE, 2010, 9
  • [30] Dimensional stability and detail reproduction of polyvinyl siloxane impression materials.
    Keskin, Y
    Uludag, BC
    Gürbüz, A
    Hasanreisoglu, U
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 447 - 447