Morphometric and Volumetric Measurements of Orbit With Cone-Beam Computed Tomography

被引:3
|
作者
Sarkar, Souvick [1 ]
Baliga, Mohan [1 ]
Prince, Jefferson [1 ]
Ongole, Ravikiran [2 ]
Natarajan, Srikant [3 ]
机构
[1] Manipal Acad Higher Educ, Manipal Coll Dent Sci, Dept Oral & Maxillofacial Surg, Manipal, Karnataka, India
[2] Manipal Acad Higher Educ, Manipal Coll Dent Sci, Dept Oral Med & Radiol, Manipal, Karnataka, India
[3] Manipal Acad Higher Educ, Manipal Coll Dent Sci, Dept Oral Pathol, Manipal, Karnataka, India
关键词
D O I
10.1016/j.joms.2020.10.026
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to determine cone-beam computed tomography (CBCT) as a tool for measuring morphometric and volumetric measurements of the orbit. Also, to assess gender and age variations and compare traditional methods of measurements in dry-skull, cadaveric, and other imaging modalities. Patients and Methods: Morphometric and volumetric values of 98 orbits (49 subjects, 21 men/28 women) were measured using CBCT. Their mean and standard deviation were measured and analyzed. The gender and age variability older and younger than 40 years were evaluated. They were compared with other dry-skull and imaging studies done among different populations. Results: CBCT could accurately measure the various morphometric and volumetric parameters of the orbit. From the reference point infraorbital foramen (I) to lacrimal fossa (F1), inferior orbital fissure (F2), inferior orbital rim (F3), and the optic canal (F4) were (in mm) (mean +/- SD) 22.88 +/- 1.08, 32.53 +/- 0.88, 7.44 +/- 0.71, and 51.45 +/- 1.28, respectively. From the reference point, superior orbital notch/foramen (S) to superior orbital fissure (S1), lacrimal fossa (S2), and the optic canal (S3) were 49.29 +/- 2.1, 26.39 +/- 1.58, and 46.82 +/- 0.88, respectively. From the reference point frontozygomatic suture (L) to lacrimal fossa (L1), superior orbital fissure (L2), the optic canal (L3), and inferior orbital fissure (L4) were 18.19 +/- 0.88, 39.91 +/- 1.44, 47.63 +/- 1.11, and 35.19 +/- 1.02, respectively. Orbital volume was found to show a significant difference between older and younger than 40 years of age, though not significant compared between men and women. Conclusion: CBCT is a viable tool for morphometric and volumetric measurements of the orbit and other orocraniofacial structures. It can also assess age and gender variability. The low cost, high accuracy, low radiation, and ease of use can help in reproducibility among the different living populations. (C) 2020 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:652 / 664
页数:13
相关论文
共 50 条
  • [41] Operational principles for cone-beam computed tomography
    Hatcher, David C.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (10): : 3S - 6S
  • [42] Cone-Beam Computed Tomography: Beyond Diagnostics
    Perel, Morton L.
    IMPLANT DENTISTRY, 2015, 24 (04) : 367 - 367
  • [43] Normal orbit skeletal changes in adolescents as determined through cone-beam computed tomography
    Lee, B.
    Flores-Mir, C.
    Lagravere, M. O.
    HEAD & FACE MEDICINE, 2016, 12
  • [44] Normal orbit skeletal changes in adolescents as determined through cone-beam computed tomography
    B. Lee
    C. Flores-Mir
    M. O. Lagravère
    Head & Face Medicine, 12
  • [45] Cone-Beam Computed Tomography (CBCT) to Computed Tomography (CT) Image Translation with Perceptual Loss to Eliminate Cone-Beam Artifacts
    Yoo, S.
    Choi, B.
    Park, I.
    Kim, J.
    Kim, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [46] Repeatability and effect of different voxel sizes on linear and volumetric tooth and pulp measurements using cone-beam computed tomography
    Ozdede, Melih
    Akay, Gulsun
    Karadag Atas, Ozge
    Koc, Emirhan Korhan
    Yalcin, Osman
    Gungor, Kahraman
    BMC ORAL HEALTH, 2024, 24 (01):
  • [47] Accuracy and Reliability of Cone-Beam Computed Tomography for Linear and Volumetric Mandibular Condyle Measurements. A Human Cadaver Study
    Garcia-Sanz, Veronica
    Bellot-Arcis, Carlos
    Hernandez, Virginia
    Serrano-Sanchez, Pedro
    Guarinos, Juan
    Paredes-Gallardo, Vanessa
    SCIENTIFIC REPORTS, 2017, 7
  • [48] Accuracy and Reliability of Cone-Beam Computed Tomography for Linear and Volumetric Mandibular Condyle Measurements. A Human Cadaver Study
    Verónica García-Sanz
    Carlos Bellot-Arcís
    Virginia Hernández
    Pedro Serrano-Sánchez
    Juan Guarinos
    Vanessa Paredes-Gallardo
    Scientific Reports, 7
  • [49] Cone-Beam Volumetric Tomography for Applications in the Temporal Bone
    Penninger, Richard T.
    Tavassolie, Tanya S.
    Carey, John P.
    OTOLOGY & NEUROTOLOGY, 2011, 32 (03) : 453 - 460
  • [50] Cone-beam computed tomography airway measurements: Can we trust them?
    Obelenis Ryan, Daniel Patrick
    Bianchi, Jonas
    Ignacio, Jaqueline
    Wolford, Larry Miller
    Goncalves, Joao Roberto
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2019, 156 (01) : 53 - 60