Morphometric and Volumetric Measurements of Orbit With Cone-Beam Computed Tomography

被引:3
|
作者
Sarkar, Souvick [1 ]
Baliga, Mohan [1 ]
Prince, Jefferson [1 ]
Ongole, Ravikiran [2 ]
Natarajan, Srikant [3 ]
机构
[1] Manipal Acad Higher Educ, Manipal Coll Dent Sci, Dept Oral & Maxillofacial Surg, Manipal, Karnataka, India
[2] Manipal Acad Higher Educ, Manipal Coll Dent Sci, Dept Oral Med & Radiol, Manipal, Karnataka, India
[3] Manipal Acad Higher Educ, Manipal Coll Dent Sci, Dept Oral Pathol, Manipal, Karnataka, India
关键词
D O I
10.1016/j.joms.2020.10.026
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to determine cone-beam computed tomography (CBCT) as a tool for measuring morphometric and volumetric measurements of the orbit. Also, to assess gender and age variations and compare traditional methods of measurements in dry-skull, cadaveric, and other imaging modalities. Patients and Methods: Morphometric and volumetric values of 98 orbits (49 subjects, 21 men/28 women) were measured using CBCT. Their mean and standard deviation were measured and analyzed. The gender and age variability older and younger than 40 years were evaluated. They were compared with other dry-skull and imaging studies done among different populations. Results: CBCT could accurately measure the various morphometric and volumetric parameters of the orbit. From the reference point infraorbital foramen (I) to lacrimal fossa (F1), inferior orbital fissure (F2), inferior orbital rim (F3), and the optic canal (F4) were (in mm) (mean +/- SD) 22.88 +/- 1.08, 32.53 +/- 0.88, 7.44 +/- 0.71, and 51.45 +/- 1.28, respectively. From the reference point, superior orbital notch/foramen (S) to superior orbital fissure (S1), lacrimal fossa (S2), and the optic canal (S3) were 49.29 +/- 2.1, 26.39 +/- 1.58, and 46.82 +/- 0.88, respectively. From the reference point frontozygomatic suture (L) to lacrimal fossa (L1), superior orbital fissure (L2), the optic canal (L3), and inferior orbital fissure (L4) were 18.19 +/- 0.88, 39.91 +/- 1.44, 47.63 +/- 1.11, and 35.19 +/- 1.02, respectively. Orbital volume was found to show a significant difference between older and younger than 40 years of age, though not significant compared between men and women. Conclusion: CBCT is a viable tool for morphometric and volumetric measurements of the orbit and other orocraniofacial structures. It can also assess age and gender variability. The low cost, high accuracy, low radiation, and ease of use can help in reproducibility among the different living populations. (C) 2020 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:652 / 664
页数:13
相关论文
共 50 条
  • [31] Validating cone-beam computed tomography for peri-implant bone morphometric analysis
    Huang, Yan
    Van Dessel, Jeroen
    Depypere, Maarten
    EzEldeen, Mostafa
    Iliescu, Alexandru Andrei
    Dos Santos, Emanuela
    Lambrichts, Ivo
    Liang, Xin
    Jacobs, Reinhilde
    BONE RESEARCH, 2014, 2
  • [32] Morphometric and morphological evaluation of mastoid emissary canal using cone-beam computed tomography
    Temiz, Mustafa
    Ozen, Duygu Celik
    Duman, Suayip Burak
    Bayrakdar, Ibrahim Sevki
    Kazan, Orhan
    Jagtap, Rohan
    Altun, Oguzhan
    Abdelkarim, Ahmed Z.
    Syed, Ali Z.
    Orhan, Kaan
    SCIENCE PROGRESS, 2023, 106 (02)
  • [33] Validating cone-beam computed tomography for peri-implant bone morphometric analysis
    Yan Huang
    Jeroen Van Dessel
    Maarten Depypere
    Mostafa EzEldeen
    Alexandru Andrei Iliescu
    Emanuela Dos Santos
    Ivo Lambrichts
    Xin Liang
    Reinhilde Jacobs
    Bone Research, 2
  • [34] Volumetric Pulp Changes after Orthodontic Treatment Determined by Cone-beam Computed Tomography
    Venkatesh, Shivanand
    Ajmera, Shreya
    Ganeshkan, Sanjay Y.
    JOURNAL OF ENDODONTICS, 2014, 40 (11) : 1758 - 1763
  • [35] A study on volumetric change of mandibular condyles with osteoarthritis using cone-beam computed tomography
    Min, Chang-Ki
    Kim, Kyoung-A
    Lee, Kyung-Eun
    Suh, Bong-Jik
    Jung, Won
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [36] Volumetric assessment of the dental crown for sex estimation by means of cone-beam computed tomography
    Daniele, Manhaes-Caldas
    Oliveira, Matheus Lima
    Groppo, Francisco Carlos
    Haiter-Neto, Francisco
    FORENSIC SCIENCE INTERNATIONAL, 2019, 303
  • [37] Volumetric measurement of the tongue and oral cavity with cone-beam computed tomography: A systematic review
    Aflah, Kannitha Alina
    Yohana, Winny
    Oscandar, Fahmi
    IMAGING SCIENCE IN DENTISTRY, 2022, 52 (04) : 333 - 342
  • [39] Evaluating the mandible with cone-beam computed tomography
    Stratemann, Scott A.
    Huang, John C.
    Maki, Koutaro
    Hatcher, David C.
    Miller, Arthur J.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : S58 - S70
  • [40] Simple ROI Cone-Beam Computed Tomography
    Maass, Clemens
    Knaup, Michael
    Sawall, Stefan
    Kachelriess, Marc
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3161 - 3168