Morphometric and Volumetric Measurements of Orbit With Cone-Beam Computed Tomography

被引:3
|
作者
Sarkar, Souvick [1 ]
Baliga, Mohan [1 ]
Prince, Jefferson [1 ]
Ongole, Ravikiran [2 ]
Natarajan, Srikant [3 ]
机构
[1] Manipal Acad Higher Educ, Manipal Coll Dent Sci, Dept Oral & Maxillofacial Surg, Manipal, Karnataka, India
[2] Manipal Acad Higher Educ, Manipal Coll Dent Sci, Dept Oral Med & Radiol, Manipal, Karnataka, India
[3] Manipal Acad Higher Educ, Manipal Coll Dent Sci, Dept Oral Pathol, Manipal, Karnataka, India
关键词
D O I
10.1016/j.joms.2020.10.026
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to determine cone-beam computed tomography (CBCT) as a tool for measuring morphometric and volumetric measurements of the orbit. Also, to assess gender and age variations and compare traditional methods of measurements in dry-skull, cadaveric, and other imaging modalities. Patients and Methods: Morphometric and volumetric values of 98 orbits (49 subjects, 21 men/28 women) were measured using CBCT. Their mean and standard deviation were measured and analyzed. The gender and age variability older and younger than 40 years were evaluated. They were compared with other dry-skull and imaging studies done among different populations. Results: CBCT could accurately measure the various morphometric and volumetric parameters of the orbit. From the reference point infraorbital foramen (I) to lacrimal fossa (F1), inferior orbital fissure (F2), inferior orbital rim (F3), and the optic canal (F4) were (in mm) (mean +/- SD) 22.88 +/- 1.08, 32.53 +/- 0.88, 7.44 +/- 0.71, and 51.45 +/- 1.28, respectively. From the reference point, superior orbital notch/foramen (S) to superior orbital fissure (S1), lacrimal fossa (S2), and the optic canal (S3) were 49.29 +/- 2.1, 26.39 +/- 1.58, and 46.82 +/- 0.88, respectively. From the reference point frontozygomatic suture (L) to lacrimal fossa (L1), superior orbital fissure (L2), the optic canal (L3), and inferior orbital fissure (L4) were 18.19 +/- 0.88, 39.91 +/- 1.44, 47.63 +/- 1.11, and 35.19 +/- 1.02, respectively. Orbital volume was found to show a significant difference between older and younger than 40 years of age, though not significant compared between men and women. Conclusion: CBCT is a viable tool for morphometric and volumetric measurements of the orbit and other orocraniofacial structures. It can also assess age and gender variability. The low cost, high accuracy, low radiation, and ease of use can help in reproducibility among the different living populations. (C) 2020 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:652 / 664
页数:13
相关论文
共 50 条
  • [1] Reliability of upper airway linear, area, and volumetric measurements in cone-beam computed tomography
    Mattos, Claudia Trindade
    Cruz, Christiane Vasconcellos
    Sobreira da Matta, Thais Cristina
    Pereira, Leonardo de Abreu
    Solon-de-Mello, Priscilla de Almeida
    de Oliveira Ruellas, Antonio Carlos
    Sant'Anna, Eduardo Franzotti
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 145 (02) : 188 - 197
  • [2] Accuracy of in-vitro tooth volumetric measurements from cone-beam computed tomography
    Ye, Niansong
    Jian, Fan
    Xue, Junjie
    Wang, Sheng
    Liao, Lina
    Huang, Wenya
    Yang, Xing
    Zhou, Yang
    Lai, Wenli
    Li, Jingtao
    Wang, Jing
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 142 (06) : 879 - 887
  • [3] Morphometric evaluation of the temporomandibular joint on cone-beam computed tomography
    Elif Ayyıldız
    Mustafa Orhan
    İlhan Bahşi
    Eda Didem Yalçin
    Surgical and Radiologic Anatomy, 2021, 43 : 975 - 996
  • [4] Morphometric evaluation of the temporomandibular joint on cone-beam computed tomography
    Ayyildiz, Elif
    Orhan, Mustafa
    Bahsi, Ilhan
    Yalcin, Eda Didem
    SURGICAL AND RADIOLOGIC ANATOMY, 2021, 43 (06) : 975 - 996
  • [5] Cone-beam computed tomography of the orbit and optic canal volumes
    Friedrich, Reinhard E.
    Bruhn, Marc
    Lohse, Christian
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (09) : 1342 - 1349
  • [6] Volumetric Measurements of Brain Shift Using Intraoperative Cone-Beam Computed Tomography: Preliminary Study
    Pereira, Vitor Mendes
    Smit-Ockeloen, Iris
    Brina, Olivier
    Babic, Drazenko
    Breeuwer, Marcel
    Schaller, Karl
    Lovblad, Karl-Olof
    Ruijters, Daniel
    OPERATIVE NEUROSURGERY, 2016, 12 (01) : 4 - 12
  • [7] Morphometric Analysis of the Mental Foramen Using Cone-Beam Computed Tomography
    Oliveira, Rudyard dos Santos
    Coutinho, Maria Rodrigues
    Panzarella, Francine Kuhl
    INTERNATIONAL JOURNAL OF DENTISTRY, 2018, 2018
  • [8] Morphometric study of the greater palatine canal: cone-beam computed tomography
    O. Rapado-González
    J. A. Suárez-Quintanilla
    X. L. Otero-Cepeda
    A. Fernández-Alonso
    M. M. Suárez-Cunqueiro
    Surgical and Radiologic Anatomy, 2015, 37 : 1217 - 1224
  • [9] Morphometric study of the greater palatine canal: cone-beam computed tomography
    Rapado-Gonzalez, O.
    Suarez-Quintanilla, J. A.
    Otero-Cepeda, X. L.
    Fernandez-Alonso, A.
    Suarez-Cunqueiro, M. M.
    SURGICAL AND RADIOLOGIC ANATOMY, 2015, 37 (10) : 1217 - 1224
  • [10] Morphometric Analysis of the Sella Turcica on Cone-Beam Computed Tomography Images
    Ince, Rumeysa
    Cihan, Omer F.
    Bahsi, Ilhan
    Yalcin, Eda D.
    JOURNAL OF CRANIOFACIAL SURGERY, 2024, 35 (07) : 1921 - 1925