Portable gas chromatograph calibration with gases of varying viscosities

被引:1
|
作者
Tschedanoff, Vera [1 ]
Schildhauer, Tilman J. [1 ]
Biollaz, Serge M. A. [1 ]
Wokaun, Alexander [1 ]
机构
[1] Paul Scherrer Inst, Gen Energy Res Dept, CH-5232 Villigen, Switzerland
关键词
NATURAL-GAS; FLUIDIZED-BED;
D O I
10.1016/j.talanta.2020.121077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The quantitative analysis of gas mixtures with gas chromatography is based on the calibration with certified standards and the determination of a response relationship for each species by regression analysis. The conventional assumption of a constant amount-of-substance injected onto the column, the sample size, for all standards analyzed represents one of the largest sources of uncertainies in this analysis technique. For systems using time-based microinjectors, the sample size injected onto the column is determined by the opening time of a pneumatically actuated microvalve and therefore depends upon the gas velocity developed in the injector's microchannel. For this reason the sample size is not necessarily constant for a given opening time, but strongly correlates - according to fluid mechanic theory - with the gas mixture's dynamic viscosity. Neglecting these sample size variations leads to errors in the analysis up to 30%, depending on the diversity of the standards' viscosities, especially in processes with strongly changing hydrogen contents. A mathematical correction exploiting the inverse proportionality of the sample size and the sample's dynamic viscosity normalizes the injection amounts and minimizes the influence of the sample variations on the calibration regression. The data analysis based on the corrected normalized calibration is no longer viscosity dependent and can be applied to gas mixtures of any composition.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] PORTABLE GAS CHROMATOGRAPH FOR ACETYLENE-REDUCTION ASSAY OF NITROGENASE
    MALLARD, TM
    MALLARD, C
    HOLFELD, HS
    LARUE, TA
    PLANT PHYSIOLOGY, 1977, 59 (06) : 94 - 94
  • [22] PORTABLE GAS CHROMATOGRAPH FOR ACETYLENE-REDUCTION ASSAY FOR NITROGENASE
    MALLARD, TM
    MALLARD, CS
    HOLFELD, HS
    LARUE, TA
    ANALYTICAL CHEMISTRY, 1977, 49 (08) : 1275 - 1277
  • [23] A MINIATURE GAS-CHROMATOGRAPH UTILIZED IN A PORTABLE GAS-ANALYSIS SYSTEM
    TERRY, SC
    JERMAN, JH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 185 (MAR): : 123 - ANYL
  • [24] DEDICATED, AUTOMATIC GAS-CHROMATOGRAPH FOR MONITORING SULFUR GASES
    DESOUZA, TLC
    JOURNAL OF CHROMATOGRAPHY, 1987, 395 : 413 - 422
  • [25] VISCOSITIES OF GASES
    DAVIS, DS
    BRITISH CHEMICAL ENGINEERING, 1969, 14 (07): : 389 - &
  • [26] CALIBRATION OF GAS-LIQUID CHROMATOGRAPH BY EMPLOYING MATHEMATICAL DESIGN
    KOZHENKOV, AV
    SOBOLEV, DM
    KONONOV, VP
    KHIMIKO-FARMATSEVTICHESKII ZHURNAL, 1988, 22 (12): : 1512 - 1515
  • [27] Gas chromatograph calibration of gas mixtures using a versatile precision volumetric apparatus
    Raal, J. David
    Nelson, Wayne Michael
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (05):
  • [29] GAS-CHROMATOGRAPH CALIBRATION TECHNIQUE BY AN EXPONENTIAL DILUTION FLASK
    GRECO, G
    GIOIA, F
    ALFANI, F
    CHIMICA & L INDUSTRIA, 1971, 53 (12): : 1133 - &
  • [30] AMBIENT CAPILLARY CHROMATOGRAPHY OF VOLATILE ORGANICS WITH A PORTABLE GAS-CHROMATOGRAPH
    JERPE, J
    DAVIS, A
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1987, 25 (04) : 154 - 157