Accelerated noncontact guided wave array imaging via sparse array data reconstruction

被引:4
|
作者
Song, Homin [1 ,2 ]
Yang, Yongchao [2 ]
机构
[1] Gachon Univ, Dept Civil & Environm Engn, 1342 Seongnamdaero, Seongnam Si 13120, Gyeonggi Do, South Korea
[2] Michigan Technol Univ, Dept Mech Engn Engn Mech, 1400 Townsend Dr, Houghton, MI 49931 USA
关键词
Guided Waves; Compressed Sensing; Noncontact Array Imaging; Scanning Laser Doppler Vibrometer; Ultrasonic Beamforming; DAMAGE DETECTION; LAMB WAVES; PHASED-ARRAYS;
D O I
10.1016/j.ultras.2021.106672
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Noncontact guided wave array imaging with a scanning laser Doppler vibrometer (SLDV) is an effective tool to detect and locate defects within a plate-like structure, as it obviates the need for installing, calibrating, and maintaining a transducer array. However, it requires collecting guided wave signals through scanning across dense spatial grid points to avoid non-defect artifacts in the array image, which is time-consuming. In this paper, we present an accelerated noncontact guided wave array imaging method that does not require dense scanning array while providing defect imaging performance comparable to the dense scanning case. In our approach, sparse scanning measurements at only a small number of points are carried out first for fast guide wave data acquisition. Then, dense guided wave array data is reconstructed from these sparse array measurements using a sparsity-promoting optimization technique, followed by delay-and-sum (DAS) beamforming to image defects within a test structure. We validate this method with laboratory experiments on composite plate specimens with multiple defects. The results demonstrate that defects within a composite plate can be successfully detected and located using sparsely sampled guided wave array measurement data. Such a significant reduction in the number of required measurement points enables accelerated noncontact guided wave array imaging.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Nonuniform sampling reconstruction applied to sparse array beamforming
    Berger, SD
    PROCEEDINGS OF THE 2002 IEEE RADAR CONFERENCE, 2002, : 98 - 103
  • [42] SIGNAL RECONSTRUCTION FROM PARTIAL DATA FOR SENSOR ARRAY IMAGING APPLICATIONS
    YEGNANARAYANA, B
    MARIADASSOU, CP
    SAINI, P
    SIGNAL PROCESSING, 1990, 19 (02) : 139 - 149
  • [43] Noninvasive Vascular Elastography Using Plane-Wave and Sparse-Array Imaging
    Korukonda, Sanghamithra
    Nayak, Rohit
    Carson, Nancy
    Schifitto, Giovanni
    Dogra, Vikram
    Doyley, Marvin M.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (02) : 332 - 342
  • [44] A Novel Sparse MIMO Array Imaging System Based on Millimeter-wave Band
    Chen, Xu
    Deng, Bin
    Yang, Qi
    Zeng, Yang
    Wang, Hongqiang
    2021 13TH GLOBAL SYMPOSIUM ON MILLIMETER-WAVES & TERAHERTZ (GSMM), 2021,
  • [45] Passive millimeter-wave imaging using a sparse phased-array antenna
    Olsen, R
    Lovberg, J
    Chou, RC
    Martin, C
    Galliano, J
    PASSIVE MILLIMETER-WAVE IMAGING TECHNOLOGY, 1997, 3064 : 63 - 70
  • [46] Beam pattern improvement by compensating array nonuniformities in a guided wave phased array
    Kwon, Hyu-Sang
    Lee, Seung-Seok
    Kim, Jin-Yeon
    SMART MATERIALS AND STRUCTURES, 2013, 22 (08)
  • [47] Ultrasonic guided wave inspection with array sensors
    To KANG
    Hak-Joon KIM
    Sung-Jin SONG
    ChineseJournalofAcoustics, 2010, 29 (04) : 377 - 385
  • [48] Multidimensional Sparse Array Storage for Data Analytics
    Otoo, E. J.
    Wang, Hairong
    Nimako, Gideon
    PROCEEDINGS OF 2016 IEEE 18TH INTERNATIONAL CONFERENCE ON HIGH PERFORMANCE COMPUTING AND COMMUNICATIONS; IEEE 14TH INTERNATIONAL CONFERENCE ON SMART CITY; IEEE 2ND INTERNATIONAL CONFERENCE ON DATA SCIENCE AND SYSTEMS (HPCC/SMARTCITY/DSS), 2016, : 1520 - 1529
  • [49] Virtual Array Plane Wave Imaging
    Cosarinsky, Guillermo
    Cruza, Jorge
    Brizuela, Jose
    Iriarte, Juan M.
    Camacho, Jorge
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [50] Millimeter wave band imaging array
    Jiang, Tao
    Hongwai/Infrared, 1992, (10): : 18 - 22