Noninvasive Vascular Elastography Using Plane-Wave and Sparse-Array Imaging

被引:47
|
作者
Korukonda, Sanghamithra [1 ]
Nayak, Rohit [1 ,2 ]
Carson, Nancy [3 ,4 ]
Schifitto, Giovanni [5 ,6 ]
Dogra, Vikram [3 ]
Doyley, Marvin M. [1 ,2 ]
机构
[1] Univ Rochester, Dept Elect & Comp Engn, Hajim Sch Engn & Appl Sci, Rochester, NY 14627 USA
[2] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY USA
[3] Univ Rochester, Med Ctr, Sch Med & Dent, Dept Imaging Sci, Rochester, NY 14642 USA
[4] Univ Rochester, Imaging Sci Ultrasound Div, Rochester, NY USA
[5] Univ Rochester, Med Ctr, Dept Neurol, Sch Med & Dent, Rochester, NY 14642 USA
[6] Univ Rochester, Clin Res Ctr, Rochester, NY USA
关键词
STRAIN; PERFORMANCE; PHANTOMS; SYSTEM;
D O I
10.1109/TUFFC.2013.2569
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Stroke may occur when an atherosclerotic plaque ruptures in the carotid artery. Noninvasive vascular elastography (NIVE) visualizes the strain distribution within the carotid artery, which is related to its mechanical properties that govern plaque rupture. Strain elastograms obtained from the transverse plane of the carotid artery are difficult to interpret, because strain is estimated in Cartesian coordinates. Sparsearray (SA) elastography overcomes this problem by transforming shear and normal strain to polar coordinates. However, the SA's transmit power may be too weak to produce useful elastograms in the clinical setting. Consequently, we are exploring other imaging methods to solve this potential problem. This study evaluated the quality of elastograms produced with SA imaging, plane-wave (PW) imaging, and compounded-plane-wave (CPW) imaging. We performed studies on simulated and physical vessel phantoms, and the carotid artery of a healthy volunteer. All echo imaging was performed with a linear transducer array that contained 128 elements, operating at 5 MHz. In SA imaging, 7 elements were fired during transmission, but all 128 elements were active during reception. In PW imaging, all 128 elements were active during both transmission and reception. We created CPW images by steering the acoustic beam within the range of -15 degrees to 15 degrees in increments of 5 degrees. SA radial and circumferential strain elastograms were comparable to those produced using PW and CPW imaging. Additionally, side-lobe levels incurred during SA imaging were 20 dB lower than those produced during PW imaging, and 10 dB lower than those computed using CPW imaging. Overall, SA imaging performs well in vivo; therefore, we plan to improve the technique and perform preclinical studies.
引用
收藏
页码:332 / 342
页数:11
相关论文
共 50 条
  • [1] Noninvasive Vascular Elastography With Plane Strain Incompressibility Assumption Using Ultrafast Coherent Compound Plane Wave Imaging
    Poree, Jonathan
    Garcia, Damien
    Chayer, Boris
    Ohayon, Jacques
    Cloutier, Guy
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (12) : 2618 - 2631
  • [2] Sparse convolutional plane-wave compounding for ultrasound imaging
    Heriard-Dubreuil, Baptiste
    Besson, Adrien
    Wintzenrieth, Frederic
    Thiran, Jean-Philippe
    Cohen-Bacrie, Claude
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [3] Principal strain vascular elastography using compounded plane wave imaging
    Nayak, Rohit
    Ohayon, Jacques
    Schifitto, Giovanni
    Doyley, Marvin
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [4] Array Smoothing Coherence Factor in the Plane-Wave Ultrasound Imaging
    Wang, Yinmeng
    Qi, Yanxing
    Wang, Yuanyuan
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2019, 9 (07) : 1483 - 1490
  • [5] A Sparse Reconstruction Framework for Fourier-Based Plane-Wave Imaging
    Besson, Adrien
    Zhang, Miaomiao
    Varray, Francois
    Liebgott, Herve
    Friboulet, Denis
    Wiaux, Yves
    Thiran, Jean-Philippe
    Carrillo, Rafael E.
    Bernard, Olivier
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (12) : 2092 - 2106
  • [6] A CIRCULAR ARRAY FOR PLANE-WAVE SYNTHESIS
    HILL, DA
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1988, 30 (01) : 3 - 8
  • [7] GPR processing using local plane-wave imaging
    Hamran, SE
    Lecomte, I
    Gelius, LJ
    GPR 2002: NINTH INTERNATIONAL CONFERENCE ON GROUND PENETRATING RADAR, 2002, 4758 : 336 - 341
  • [8] Reproduction of a plane-wave sound field using an array of loudspeakers
    Ward, DB
    Abhayapala, TD
    IEEE TRANSACTIONS ON SPEECH AND AUDIO PROCESSING, 2001, 9 (06): : 697 - 707
  • [9] PLANE-WAVE DIFFRACTION BY THE ARRAY OF PLANE WAVEGUIDES WITH DISCONTINUITIES
    POLUBOTKO, AM
    STEPANOV, VA
    RADIOTEKHNIKA I ELEKTRONIKA, 1979, 24 (04): : 836 - 839
  • [10] Plane-Wave Synthesis: A Sparse Representation Perspective
    Li, Yong
    Gao, Lingyu
    Sun, Hao
    Zhang, Xiang
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2020, 19 (09): : 1644 - 1648