Noninvasive Vascular Elastography Using Plane-Wave and Sparse-Array Imaging

被引:47
|
作者
Korukonda, Sanghamithra [1 ]
Nayak, Rohit [1 ,2 ]
Carson, Nancy [3 ,4 ]
Schifitto, Giovanni [5 ,6 ]
Dogra, Vikram [3 ]
Doyley, Marvin M. [1 ,2 ]
机构
[1] Univ Rochester, Dept Elect & Comp Engn, Hajim Sch Engn & Appl Sci, Rochester, NY 14627 USA
[2] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY USA
[3] Univ Rochester, Med Ctr, Sch Med & Dent, Dept Imaging Sci, Rochester, NY 14642 USA
[4] Univ Rochester, Imaging Sci Ultrasound Div, Rochester, NY USA
[5] Univ Rochester, Med Ctr, Dept Neurol, Sch Med & Dent, Rochester, NY 14642 USA
[6] Univ Rochester, Clin Res Ctr, Rochester, NY USA
关键词
STRAIN; PERFORMANCE; PHANTOMS; SYSTEM;
D O I
10.1109/TUFFC.2013.2569
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Stroke may occur when an atherosclerotic plaque ruptures in the carotid artery. Noninvasive vascular elastography (NIVE) visualizes the strain distribution within the carotid artery, which is related to its mechanical properties that govern plaque rupture. Strain elastograms obtained from the transverse plane of the carotid artery are difficult to interpret, because strain is estimated in Cartesian coordinates. Sparsearray (SA) elastography overcomes this problem by transforming shear and normal strain to polar coordinates. However, the SA's transmit power may be too weak to produce useful elastograms in the clinical setting. Consequently, we are exploring other imaging methods to solve this potential problem. This study evaluated the quality of elastograms produced with SA imaging, plane-wave (PW) imaging, and compounded-plane-wave (CPW) imaging. We performed studies on simulated and physical vessel phantoms, and the carotid artery of a healthy volunteer. All echo imaging was performed with a linear transducer array that contained 128 elements, operating at 5 MHz. In SA imaging, 7 elements were fired during transmission, but all 128 elements were active during reception. In PW imaging, all 128 elements were active during both transmission and reception. We created CPW images by steering the acoustic beam within the range of -15 degrees to 15 degrees in increments of 5 degrees. SA radial and circumferential strain elastograms were comparable to those produced using PW and CPW imaging. Additionally, side-lobe levels incurred during SA imaging were 20 dB lower than those produced during PW imaging, and 10 dB lower than those computed using CPW imaging. Overall, SA imaging performs well in vivo; therefore, we plan to improve the technique and perform preclinical studies.
引用
收藏
页码:332 / 342
页数:11
相关论文
共 50 条
  • [41] ANALYSIS OF THE PROBLEM OF THE PLANE-WAVE DIFFRACTION ON THE ANTENNA-ARRAY USING THE AUXILIARY SOURCES METHOD
    MALAKSHINOV, NP
    ERIKHOV, VG
    YAKIMOV, IL
    RADIOTEKHNIKA I ELEKTRONIKA, 1980, 25 (08): : 1607 - 1613
  • [42] Universal Plane-Wave Compounding for High Quality US Imaging Using Deep Learning
    Khan, Shujaat
    Huh, Jaeyoung
    Ye, Jong Chul
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 2345 - 2347
  • [43] High-quality Reconstruction of Plane-wave Imaging Using Generative Adversarial Network
    Zhang, Xi
    Liu, Jing
    He, Qiong
    Zhang, Heye
    Luo, Jianwen
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [44] REFLECTION AND TRANSMISSION OF A PLANE-WAVE BY AN ARRAY OF CAVITIES IN THE INTERFACE OF 2 SOLIDS
    XU, YG
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1992, 59 (01): : 102 - 108
  • [45] DIFFRACTION OF THE PLANE-WAVE BY THE PERIODIC ARRAY CONTAINING LOADED STRIPE SPIRALS
    DMITRIEV, VI
    CHEBYSHEV, VV
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOFIZIKA, 1988, 31 (02): : 172 - 179
  • [46] PLANE-WAVE REFRACTION BY THE PERIODIC ARRAY OF ELLIPTIC CYLINDERS WITH MULTILAYERED DAMPPHER
    BYKOV, AA
    RADIOTEKHNIKA I ELEKTRONIKA, 1990, 35 (11): : 2437 - 2439
  • [47] FLUCTUATIONS OF THE ANGLE OF ARRIVAL AT A LINE ARRAY BY A PLANE-WAVE PROPAGATING IN THE OCEAN
    ELISEEVKIN, VA
    SOVIET PHYSICS ACOUSTICS-USSR, 1979, 25 (04): : 355 - 356
  • [48] Frame rate improvement in coherent plane-wave compounding using null subtraction imaging
    Xu, Yijun
    Li, Boyi
    Luo, Jianwen
    Liu, Xin
    Ta, Dean
    AIP ADVANCES, 2024, 14 (06)
  • [49] SHIELDING OF A PLANE-WAVE BY A CYLINDRICAL ARRAY OF INFINITELY LONG THIN WIRES
    WILSON, LO
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1974, AP22 (05) : 689 - 696
  • [50] Coherent Plane-Wave Compounding for Very High Frame Rate Ultrasonography and Transient Elastography
    Montaldo, Gabriel
    Tanter, Mickael
    Bercoff, Jeremy
    Benech, Nicolas
    Fink, Mathias
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (03) : 489 - 506