Vibrating Mesh Nebulizer Compared With Metered-Dose Inhaler in Mechanically Ventilated Subjects

被引:10
|
作者
Dubosky, Meagan N. [1 ]
Chen, Yi-Fan [2 ]
Henriksen, Mary E. [1 ]
Vines, David L. [1 ]
机构
[1] Rush Univ, Med Ctr, Dept Cardiopulm Sci, Chicago, IL 60612 USA
[2] Univ Illinois, Inst Hlth Res & Policy, Chicago, IL USA
基金
美国国家卫生研究院;
关键词
metered dose inhalers; nebulizer; ventilators; mechanical; administration; inhalation; patient outcome assessment; APACHE; pneumonia; ventilator-associated; PNEUMONIA; THERAPY;
D O I
10.4187/respcare.04823
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: The impact of various aerosol delivery devices on patient outcomes during mechanical ventilation is unknown. If one method of delivery results in a higher ventilator-associated pneumonia (VAP) rate than another, multiple patient outcomes may be affected. This study aimed to determine whether there was a difference in VAP occurrence and patient outcomes (days receiving ventilation and in-hospital mortality) between the vibrating mesh nebulizer (AeroNeb Solo) and the metered-dose inhaler (MDI). METHODS: This retrospective study reviewed medical records for all mechanically ventilated, adult patients with an order for aerosol treatment from August 2011 to August 2013. The hospital converted from MDI to vibrating mesh nebulizers in August 2012, and data were gathered 1 y before/after conversion. Excluded were patients with a tracheostomy, patients whO were mechanically ventilated for <24 h, patients who received a combination of nebulizer and MDI treatments, or patients who were re-intubated. RESULTS: Two hundred twenty-eight subjects were included. Forty-eight (21%) received treatment with an MDI, and 180 (79%) were treated with the vibrating mesh nebulizer. Descriptive data did not significantly differ for age or APACHE II (Acute Physiology and Chronic Health Evaluation H) scores between the groups but did for sex (P =.03). Difference in median days receiving ventilation for the MDI (5 d, interquartile range 3.0-8.5 d) and the vibrating mesh nebulizer (6 d, interquartile range 4.0-10.0 d) was not statistically significant. No correlation was found between the use of either device and the primary outcomes of VAP and in-hospital mortality. In multivariable logistic regression analysis, the number of days receiving ventilation increased the odds of VAP (odds ratio [OR] 13, 95% CI 1.14-1.49, P <.001) and mortality (OR 1.12, 95% CI 1.04-1.21, P =.002). Higher APACHE II scores increased the odds of mortality (OR 1.05, 95% CI 1.001-1.092, P =.044). CONCLUSION: We found no association between an MDI or vibrating mesh nebulizer and our primary outcomes, days receiving ventilation, in-hospital mortality, or VAP, in mechanically ventilated subjects.
引用
收藏
页码:391 / 395
页数:5
相关论文
共 50 条
  • [41] Recommendation for modified metered-dose inhaler
    Ahmed, S
    Gunaratnam, NT
    Patton, WF
    AMERICAN FAMILY PHYSICIAN, 2002, 66 (08) : 1401 - 1401
  • [42] PENTAMIDINE PROPHYLAXIS WITH A METERED-DOSE INHALER
    MILLER, RF
    BUCKLAND, JA
    PANG, M
    QIU, J
    TAYLOR, KMG
    LANCET, 1991, 337 (8755): : 1489 - 1489
  • [43] INHALATION OF THE CAP OF A METERED-DOSE INHALER
    LI, JTC
    GUNDERSON, D
    NEW ENGLAND JOURNAL OF MEDICINE, 1991, 325 (06): : 431 - 431
  • [44] EFFECT OF THE HEATED HUMIDIFICATION ON THE IN VITRO AEROSOL DELIVERY WITH A PRESSURIZED-METERED DOSE INHALER AND WITH A VIBRATING MESH NEBULIZER IN MECHANICAL VENTILATION
    Eckes, Myriam
    Poree, Thierry
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2020, 33 (02) : A9 - A9
  • [45] Salmeterol administration by metered-dose inhaler alone vs metered-dose inhaler plus valved holding chamber
    Demirkan, K
    Tolley, E
    Mastin, T
    Soberman, J
    Burbeck, J
    Self, T
    CHEST, 2000, 117 (05) : 1314 - 1318
  • [46] METERED-DOSE INHALER USAGE RECORDED BY NEBULIZER CHRONOLOGY - COMPARISON WITH DAILY DIARIES IN 75 ASTHMATICS
    GONG, H
    SIMMONS, MS
    CLARK, VA
    TASHKIN, DP
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1986, 133 (04): : A58 - A58
  • [47] Pressurized Metered-Dose Inhalers Versus Nebulizers in the Treatment of Mechanically Ventilated Subjects With Artificial Airways: An In Vitro Study
    Ari, Arzu
    Harwood, Robert J.
    Sheard, Meryl M.
    Fink, James B.
    Respiratory Care, 2015, 60 (11) : 1570 - 1574
  • [48] USE OF A COMMON CANISTER METERED DOSE INHALER PROTOCOL IN MECHANICALLY VENTILATED PATIENTS
    Gowan, Mollie
    Bushwitz, Jennifer
    Watts, Peggy
    Silver, Patty
    Jackson, Mark
    Hampton, Nicholas
    Kollef, Marin
    CRITICAL CARE MEDICINE, 2015, 43 (12)
  • [49] A COMPARISON OF ALBUTEROL ADMINISTERED BY METERED-DOSE INHALER (AND HOLDING CHAMBER) OR WET NEBULIZER IN ACUTE ASTHMA
    COLACONE, A
    AFILALO, M
    WOLKOVE, N
    KREISMAN, H
    CHEST, 1993, 104 (03) : 835 - 841
  • [50] DELIVERY OF METERED-DOSE INHALER AEROSOLS TO PARALYZED AND NON-PARALYZED VENTILATED RABBITS
    FOK, TF
    ALESSA, M
    MONKMAN, S
    DOLOVICH, M
    GIRARD, L
    COATES, G
    KIRPALANI, H
    PEDIATRIC RESEARCH, 1995, 38 (03) : 432 - 432