Vibrating Mesh Nebulizer Compared With Metered-Dose Inhaler in Mechanically Ventilated Subjects

被引:10
|
作者
Dubosky, Meagan N. [1 ]
Chen, Yi-Fan [2 ]
Henriksen, Mary E. [1 ]
Vines, David L. [1 ]
机构
[1] Rush Univ, Med Ctr, Dept Cardiopulm Sci, Chicago, IL 60612 USA
[2] Univ Illinois, Inst Hlth Res & Policy, Chicago, IL USA
基金
美国国家卫生研究院;
关键词
metered dose inhalers; nebulizer; ventilators; mechanical; administration; inhalation; patient outcome assessment; APACHE; pneumonia; ventilator-associated; PNEUMONIA; THERAPY;
D O I
10.4187/respcare.04823
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: The impact of various aerosol delivery devices on patient outcomes during mechanical ventilation is unknown. If one method of delivery results in a higher ventilator-associated pneumonia (VAP) rate than another, multiple patient outcomes may be affected. This study aimed to determine whether there was a difference in VAP occurrence and patient outcomes (days receiving ventilation and in-hospital mortality) between the vibrating mesh nebulizer (AeroNeb Solo) and the metered-dose inhaler (MDI). METHODS: This retrospective study reviewed medical records for all mechanically ventilated, adult patients with an order for aerosol treatment from August 2011 to August 2013. The hospital converted from MDI to vibrating mesh nebulizers in August 2012, and data were gathered 1 y before/after conversion. Excluded were patients with a tracheostomy, patients whO were mechanically ventilated for <24 h, patients who received a combination of nebulizer and MDI treatments, or patients who were re-intubated. RESULTS: Two hundred twenty-eight subjects were included. Forty-eight (21%) received treatment with an MDI, and 180 (79%) were treated with the vibrating mesh nebulizer. Descriptive data did not significantly differ for age or APACHE II (Acute Physiology and Chronic Health Evaluation H) scores between the groups but did for sex (P =.03). Difference in median days receiving ventilation for the MDI (5 d, interquartile range 3.0-8.5 d) and the vibrating mesh nebulizer (6 d, interquartile range 4.0-10.0 d) was not statistically significant. No correlation was found between the use of either device and the primary outcomes of VAP and in-hospital mortality. In multivariable logistic regression analysis, the number of days receiving ventilation increased the odds of VAP (odds ratio [OR] 13, 95% CI 1.14-1.49, P <.001) and mortality (OR 1.12, 95% CI 1.04-1.21, P =.002). Higher APACHE II scores increased the odds of mortality (OR 1.05, 95% CI 1.001-1.092, P =.044). CONCLUSION: We found no association between an MDI or vibrating mesh nebulizer and our primary outcomes, days receiving ventilation, in-hospital mortality, or VAP, in mechanically ventilated subjects.
引用
收藏
页码:391 / 395
页数:5
相关论文
共 50 条
  • [21] Lower oropharyngeal deposition of inhaled ciclesonide via hydrofluoroalkane metered-dose inhaler compared with budesonide via chlorofluorocarbon metered-dose inhaler in healthy subjects
    Ruediger Nave
    Karl Zech
    Thomas D. Bethke
    European Journal of Clinical Pharmacology, 2005, 61 : 203 - 208
  • [22] Lower oropharyngeal deposition of inhaled ciclesonide via hydrofluoroalkane metered-dose inhaler compared with budesonide via chlorofluorocarbon metered-dose inhaler in healthy subjects
    Nave, R
    Zech, K
    Bethke, TD
    EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 2005, 61 (03) : 203 - 208
  • [23] Inhaled salbutamol dose delivered by jet nebulizer, vibrating mesh nebulizer and metered dose inhaler with spacer during invasive mechanical ventilation
    ElHansy, Muhammad H. E.
    Boules, Marina E.
    El Essawy, Assem Fouad Mohamed
    Al-Kholy, Mohamed Bakry
    Abdelrahman, Maha M.
    Said, Amira S. A.
    Hussein, Raghda R. S.
    Abdelrahim, Mohamed E.
    PULMONARY PHARMACOLOGY & THERAPEUTICS, 2017, 45 : 159 - 163
  • [24] METERED-DOSE INHALER VERSUS NEBULIZER IN METHACHOLINE BRONCHIAL PROVOCATION TEST
    ROCHE, N
    ELHUSSEINI, F
    LABRUNE, S
    CHINET, T
    GIRAUD, V
    HUCHON, GJ
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (04): : A830 - A830
  • [25] Paradoxical bronchoconstriction with albuterol administered by metered-dose inhaler and nebulizer solution
    Spooner, LM
    Olin, JL
    ANNALS OF PHARMACOTHERAPY, 2005, 39 (11) : 1924 - 1927
  • [26] Use of a Shared Canister Protocol for the Delivery of Metered-Dose Inhalers in Mechanically Ventilated Subjects
    Gowan, Mollie
    Bushwitz, Jennifer
    Watts, Peggy
    Silver, Patty C.
    Jackson, Mark
    Hampton, Nicholas
    Kollef, Marin H.
    RESPIRATORY CARE, 2016, 61 (10) : 1285 - 1292
  • [27] Delivery of salbutamol to nonventilated preterm infants by metered-dose inhaler, jet nebulizer, and ultrasonic nebulizer
    Fok, TF
    Lam, K
    Ng, PC
    Leung, TF
    So, HK
    Cheung, KL
    Wong, W
    EUROPEAN RESPIRATORY JOURNAL, 1998, 12 (01) : 159 - 164
  • [28] Paradoxical bronchoconstriction with salbutamol and terbutalin administered by metered-dose inhaler and nebulizer solution
    Khalifa, Islem Hadj
    Ayed, Khadija
    Mokaddem, Salma
    Ben Khamsa, Saloua
    ACTA PHYSIOLOGICA, 2016, 217 : 58 - 59
  • [29] COMPARISON OF BRONCHODILATOR EFFECTS OF METERED-DOSE INHALER AND NEBULIZER TREATMENTS WITH BITOLTEROL MESYLATE
    BHATT, BD
    CHEN, TM
    NEIDL, MJ
    PINNAS, JL
    ANNALS OF ALLERGY, 1985, 55 (02): : 396 - 396
  • [30] RELATIVE POTENCY OF AEROSOL ALBUTEROL ADMINISTERED BY METERED-DOSE INHALER AND NEBULIZER SOLUTION
    HOPPE, MM
    BLAKE, KV
    HENDELES, L
    HARMAN, E
    PHARMACOTHERAPY, 1988, 8 (02): : 130 - 130