Vibrating Mesh Nebulizer Compared With Metered-Dose Inhaler in Mechanically Ventilated Subjects

被引:10
|
作者
Dubosky, Meagan N. [1 ]
Chen, Yi-Fan [2 ]
Henriksen, Mary E. [1 ]
Vines, David L. [1 ]
机构
[1] Rush Univ, Med Ctr, Dept Cardiopulm Sci, Chicago, IL 60612 USA
[2] Univ Illinois, Inst Hlth Res & Policy, Chicago, IL USA
基金
美国国家卫生研究院;
关键词
metered dose inhalers; nebulizer; ventilators; mechanical; administration; inhalation; patient outcome assessment; APACHE; pneumonia; ventilator-associated; PNEUMONIA; THERAPY;
D O I
10.4187/respcare.04823
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: The impact of various aerosol delivery devices on patient outcomes during mechanical ventilation is unknown. If one method of delivery results in a higher ventilator-associated pneumonia (VAP) rate than another, multiple patient outcomes may be affected. This study aimed to determine whether there was a difference in VAP occurrence and patient outcomes (days receiving ventilation and in-hospital mortality) between the vibrating mesh nebulizer (AeroNeb Solo) and the metered-dose inhaler (MDI). METHODS: This retrospective study reviewed medical records for all mechanically ventilated, adult patients with an order for aerosol treatment from August 2011 to August 2013. The hospital converted from MDI to vibrating mesh nebulizers in August 2012, and data were gathered 1 y before/after conversion. Excluded were patients with a tracheostomy, patients whO were mechanically ventilated for <24 h, patients who received a combination of nebulizer and MDI treatments, or patients who were re-intubated. RESULTS: Two hundred twenty-eight subjects were included. Forty-eight (21%) received treatment with an MDI, and 180 (79%) were treated with the vibrating mesh nebulizer. Descriptive data did not significantly differ for age or APACHE II (Acute Physiology and Chronic Health Evaluation H) scores between the groups but did for sex (P =.03). Difference in median days receiving ventilation for the MDI (5 d, interquartile range 3.0-8.5 d) and the vibrating mesh nebulizer (6 d, interquartile range 4.0-10.0 d) was not statistically significant. No correlation was found between the use of either device and the primary outcomes of VAP and in-hospital mortality. In multivariable logistic regression analysis, the number of days receiving ventilation increased the odds of VAP (odds ratio [OR] 13, 95% CI 1.14-1.49, P <.001) and mortality (OR 1.12, 95% CI 1.04-1.21, P =.002). Higher APACHE II scores increased the odds of mortality (OR 1.05, 95% CI 1.001-1.092, P =.044). CONCLUSION: We found no association between an MDI or vibrating mesh nebulizer and our primary outcomes, days receiving ventilation, in-hospital mortality, or VAP, in mechanically ventilated subjects.
引用
收藏
页码:391 / 395
页数:5
相关论文
共 50 条
  • [1] Conversion of Pressurized Metered-Dose Inhaler to Vibrating Mesh Nebulizer Administered Medications
    McDaniel, Cara
    Glynn, Brian
    Gudowski, Steven
    Pezzano, Tiffany
    Weibel, Sandra
    CRITICAL CARE MEDICINE, 2013, 41 (12)
  • [2] Efficiency of bronchodilator administration by metered-dose inhaler or nebulizer to mechanically ventilated patients.
    Duarte, A
    Fink, JB
    Bidani, A
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A828 - A828
  • [3] Use of a Metered-Dose Inhaler Compared With a Vibrating Mesh Nebulizer During Mechanical Ventilation: Does It Really Matter?
    Gilmore, Tim W.
    RESPIRATORY CARE, 2017, 62 (04) : 513 - 514
  • [4] METERED-DOSE INHALER VERSUS NEBULIZED ALBUTEROL IN MECHANICALLY VENTILATED PATIENTS
    MANTHOUS, CA
    HALL, JB
    SCHMIDT, GA
    WOOD, LDH
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 148 (06): : 1567 - 1570
  • [5] TREATMENT OF BRONCHOSPASM BY METERED-DOSE INHALER ALBUTEROL IN MECHANICALLY VENTILATED PATIENTS
    MANTHOUS, CA
    CHATILA, W
    SCHMIDT, GA
    HALL, JB
    CHEST, 1995, 107 (01) : 210 - 213
  • [6] THE METERED-DOSE INHALER SUPERSEDES THE JET NEBULIZER
    HOFFORD, JM
    CHEST, 1993, 103 (01) : 327 - 329
  • [7] METERED-DOSE INHALER AND NEBULIZER IN ACUTE ASTHMA
    LIN, YZ
    HSIEH, KH
    ARCHIVES OF DISEASE IN CHILDHOOD, 1995, 72 (03) : 214 - 218
  • [8] PULMONARY DEPOSITION OF SALBUTAMOL AEROSOL DELIVERED BY METERED-DOSE INHALER (MDI), JET NEBULIZER AND ULTRASONIC NEBULIZER IH MECHANICALLY VENTILATED RABBITS
    FOK, TF
    ALESSA, MM
    MONKMAN, S
    DOLOVICH, BM
    COATES, G
    BOWEN, B
    KIRPALANI, HM
    PEDIATRIC RESEARCH, 1994, 36 (01) : A21 - A21
  • [9] Serum albuterol levels in mechanically ventilated patients and healthy subjects after metered-dose inhaler administration
    Duarte, AG
    Dhand, R
    Reid, R
    Fink, JB
    Fahey, PJ
    Tobin, MJ
    Jenne, JW
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (06) : 1658 - 1663
  • [10] Metered-Dose Inhaler Compared To Nebulizer For Bronchodilator Treatment Of Inpatients With Asthma Exacerbation
    Pajor, N. M.
    Nevin, M. A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193