Optimizing an analytical dose calculation algorithm for fast 2D calculations

被引:0
|
作者
Lorenz, Friedlieb [1 ]
Richter, Henning [2 ]
Zygmanski, Piotr [3 ]
机构
[1] Heidelberg Univ, Dept Radiat Oncol, Mannheim Med Ctr, D-68167 Mannheim, Germany
[2] Tech Univ Kaiserslautern, Kaiserslautern, Germany
[3] Harvard Univ, Sch Med, Dept Radiat Oncol, Dana Farber Brigham & Womens Canc Ctr, Boston, MA USA
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2010年 / 20卷 / 01期
关键词
Dose calculation; MLC transmission; independent verification; RADIATION-THERAPY COMMITTEE; SPATIAL DEPENDENCE; MLC TRANSMISSION; RADIOTHERAPY; DELIVERY; IMRT;
D O I
10.1016/j.zemedi.2009.12.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Previously, an analytical dose calculation algorithm for MLC-based radiotherapy was developed and commissioned, which includes a detailed model of various MLC effects as a unique feature [1]. The algorithm was originally developed as an independent verification of the treatment planning system's dose calculation and it explicitly modeled spatial and depth dependent MLC effects such as interleaf transmission, the tongue-and-groove effect, rounded leaf ends, MLC scatter, beam hardening, and divergence of the beam, which in turn resulted in a gradual MLC transmission frill-off with increasing off-axis distance. Originally the algorithm was implemented in Mathematica (TM) (Wolfram). To speed up the calculation time and to be able to calculate high resolution 2D dose distributions within a reasonable time frame (<2 s) the algorithm needs to be optimized and to be embedded in a user friendly environment. To achieve this goal, the dose calculation model is implemented in VisualBasic 6.0, which decreases the calculation time moderately. More importantly, the numerical algorithm for dose calculation is changed at two levels: the dose contributions are split into their x- and y-contributions and the calculation is aperture- rather than as originally point-based. Implementing these three major changes, the calculation time is reduced considerably without loosing accuracy. The time for a typical IMRT field with about 2500 calculation points decreased from 2387 seconds to 0.624 seconds (a factor of about 3800). The mean agreement of the optimized and the not optimized calculation algorithm at the isocenter fir a fairly complex IMRT plan with 23 fields is better than 1% relative to the local dose at the measuring point.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [31] Fast 2D Walsh transform for the truecolor image compression algorithm
    Karagodin, MA
    Burkatovskaya, JB
    Osokin, AN
    Korus 2005, Proceedings, 2005, : 634 - 636
  • [32] Fast algorithm for 2D fragment assembly based on partial EMD
    Meng Zhang
    Shuangmin Chen
    Zhenyu Shu
    Shi-Qing Xin
    Jieyu Zhao
    Guang Jin
    Rong Zhang
    Jürgen Beyerer
    The Visual Computer, 2017, 33 : 1601 - 1612
  • [33] A FAST ALGORITHM FOR CONVEX-HULL EXTRACTION IN 2D IMAGES
    YE, QZ
    PATTERN RECOGNITION LETTERS, 1995, 16 (05) : 531 - 537
  • [34] Fast pressure calculation for 2D and 3D time dependent incompressible flow
    van Kan, J
    Vuik, C
    Wesseling, P
    NUMERICAL LINEAR ALGEBRA WITH APPLICATIONS, 2000, 7 (06) : 429 - 447
  • [35] A fast and robust algorithm for 2D/3D panorama ultrasound data
    Scherzer, O
    Schoisswohl, A
    REAL-TIME IMAGING, 2002, 8 (01) : 53 - 60
  • [36] Application of a fast proton dose calculation algorithm to a thorax geometry
    Yepes, Pablo P.
    Brannan, Travis
    Huang, Jessie
    Mirkovic, Dragan
    Newhauser, Wayne D.
    Taddei, Phillip J.
    Titt, Uwe
    RADIATION MEASUREMENTS, 2010, 45 (10) : 1367 - 1368
  • [37] Fast dose calculation with superposition algorithm using a scaling method
    Fan, Y.
    Nath, R.
    MEDICAL PHYSICS, 2007, 34 (06) : 2454 - 2454
  • [38] 2D fast facts
    Autom I D News, 10 (33):
  • [39] A method for fast 3-D IMRT dose calculations: The quadrant infinite beam (QIB) algorithm
    Kalinin, E
    Deasy, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1348 - 1349
  • [40] Validation and Application of a Fast Monte Carlo Algorithm for Assessing the Clinical Impact of Approximations in Analytical Dose Calculations for Proton Therapy
    Huang, S.
    Souris, K.
    Li, S.
    Kang, M.
    Janssens, G.
    Lin, A.
    Garver, E.
    Ainsley, C.
    Xiao, Y.
    Lin, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E431 - E432