Predictors of conduction disturbances after transcatheter aortic valve implantation with balloon-expandable valve for bicuspid aortic valve stenosis

被引:3
|
作者
Miyashita, Hirokazu [1 ,2 ]
Moriyama, Noriaki
Yamanaka, Futoshi [3 ]
Saito, Shigeru [3 ]
Lehtola, Heidi [4 ]
Piuhola, Jarkko [4 ]
Niemela, Matti [4 ]
Laine, Mika [1 ,2 ]
机构
[1] Univ Helsinki, Heart & Lung Ctr, Dept Cardiol, Helsinki, Finland
[2] Helsinki Univ Cent Hosp, Helsinki, Finland
[3] Shonan Kamakura Gen Hosp, Dept Cardiol, Kamakura, Kanagawa, Japan
[4] Oulu Univ Hosp, Dept Cardiol, Oulu, Finland
关键词
aortic stenosis; bicuspid aortic valve; conduction disorder; implantation depth; membranous septum length; transcatheter aortic valve replacement; PERMANENT PACEMAKER IMPLANTATION; REPLACEMENT; RISK; OUTCOMES; CALCIFICATION; LENGTH; IMPACT; ROOT;
D O I
10.1111/jce.15525
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Implantation depth and membranous septum (MS) length have been established as the predictors of new-onset conduction disturbance (CD) after transcatheter aortic valve replacement (TAVR) for tricuspid aortic valve (TAV) stenosis. However, little is known about the predictors with bicuspid aortic valve (BAV). This study investigated the role of MS length and implantation depth in predicting CD following TAVR with a balloon-expandable valve in patients with BAV. Methods This retrospective study analyzed 169 patients who underwent TAVR for BAV with balloon-expandable valve, and TAV cohort was established as a control group using propensity score (PS) matching. The primary endpoints were in-hospital new permanent pacemaker implantation (PPI) and new-onset CD (the composite outcome of new-onset left bundle branch block and new PPI). Results PPI developed in 14 patients (8.3%) and new-onset CD in 37 patients (21.9%) in the BAV cohort. Multivariate analysis revealed severe left ventricle outflow tract (LVOT) calcification (odds ratio [OR]: 5.83, 95% confidence interval [CI]: 1.08-31.5, p = .0407) and implantation depth-MS length (OR: 1.30, 95% CI: 1.12-1.51, p = .0005) as the predictors of new-onset CD within the BAV cohort. The matched comparison between BAV and TAV groups showed similar MS length (3.0 vs. 3.2 mm, p = .5307), but valves were implanted more deeply in the BAV group than in the TAV group (3.9 vs. 3.0 mm, p < .0001). New-onset CD was more frequent in patients who had BAV (22.3% vs. 13.9%, p = .0458). Conclusion The implantation depth-MS length, and severe LVOT calcification predicted new-onset CD following TAVR in BAV with balloon-expandable valve. Among BAV patients, THV THV were implanted more deeply compared to THV patients. High deployment technique could be considered to avoid new-onset CD in BAV anatomy.
引用
收藏
页码:1576 / 1586
页数:11
相关论文
共 50 条
  • [21] Balloon-Expandable Transcatheter Aortic Valve Replacement in Patients with Severe Aortic Stenosis and Mild Aortic Valve Calcification
    Abramowitz, Yigal
    Jilaihawi, Hasan
    Chakravarty, Tarun
    Kashif, Mohammad
    Kazuno, Yoshio
    Maeno, Yoshio
    Takahashi, Nobuyuki
    Kawamori, Hiroyuki
    Sharma, Rahul P.
    Cox, Justin
    Cheng, Wen
    Makkar, Raj
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B257 - B257
  • [22] Conduction delays after transcatheter aortic valve implantation with balloon-expandable prosthesis and high implantation technique
    Fortunato Iacovelli
    Giuseppe Giugliano
    Donato Gerardi
    Luigi Salemme
    Angelo Cioppa
    Armando Pucciarelli
    Grigore Popusoi
    Francesco Loizzi
    Giancarlo Schettino
    Stefano Favale
    Francesco Solimene
    Giovanni Esposito
    Tullio Tesorio
    Eugenio Stabile
    Heart and Vessels, 2022, 37 : 337 - 346
  • [23] Conduction delays after transcatheter aortic valve implantation with balloon-expandable prosthesis and high implantation technique
    Iacovelli, Fortunato
    Giugliano, Giuseppe
    Gerardi, Donato
    Salemme, Luigi
    Cioppa, Angelo
    Pucciarelli, Armando
    Popusoi, Grigore
    Loizzi, Francesco
    Schettino, Giancarlo
    Favale, Stefano
    Solimene, Francesco
    Esposito, Giovanni
    Tesorio, Tullio
    Stabile, Eugenio
    HEART AND VESSELS, 2022, 37 (02) : 337 - 346
  • [24] Redo surgery after transcatheter aortic valve replacement with a balloon-expandable valve
    Nakazato, Taro
    Toda, Koichi
    Kuratani, Toru
    Sawa, Yoshiki
    JTCVS TECHNIQUES, 2020, 3 : 72 - 74
  • [25] Transcatheter aortic valve implantation with balloon-expandable valve: early experience from China
    Lu, Qingsheng
    Pei, Yifei
    Wu, Hong
    Wang, Zhinong
    Jing Zaiping
    REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2015, 30 (04): : 425 - 432
  • [26] Transcatheter Aortic Valve Implantation for Patients With Severe Bicuspid Aortic Valve Stenosis
    Hayashida, Kentaro
    Bouvier, Erik
    Lefevre, Thierry
    Chevalier, Bernard
    Hovasse, Thomas
    Romano, Mauro
    Garot, Philippe
    Watanabe, Yusuke
    Farge, Arnaud
    Donzeau-Gouge, Patrick
    Cormier, Bertrand
    Morice, Marie-Claude
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (03) : 284 - 291
  • [27] TRANSCATHETER AORTIC VALVE IMPLANTATION FOR PATIENTS WITH BICUSPID SEVERE AORTIC VALVE STENOSIS
    Hayashida, Kentaro
    Lefevre, Thierry
    Chevalier, Bernard
    Hovasse, Thomas
    Romano, Mauro
    Garot, Philippe
    Farge, Arnaud
    Donzeau-Gouge, Patrick
    Bouvier, Erik
    Cormier, Bertrand
    Morice, Marie-Claude
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E4 - E4
  • [28] Editorial commentary: Transcatheter aortic valve implantation in bicuspid aortic valve stenosis
    Sa, Michel Pompeu
    Jacquemyn, Xander
    Sultan, Ibrahim
    TRENDS IN CARDIOVASCULAR MEDICINE, 2024, 34 (05) : 314 - 316
  • [29] Transapical Mitral Implantation of a Balloon-Expandable Valve in Native Mitral Valve Stenosis in a Patient With Previous Transcatheter Aortic Valve Replacement
    Ribeiro, Henrique Barbosa
    Doyle, Daniel
    Urena, Marina
    Allende, Ricardo
    Amat-Santos, Ignacio
    Pasian, Sergio
    Bilodeau, Sylvie
    Mohammadi, Siamak
    Paradis, Jean-Michel
    DeLarochelliere, Robert
    Rodes-Cabau, Josep
    Dumont, Eric
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (10) : E137 - E139
  • [30] Transaortic balloon-expandable aortic valve implantation
    Gerosa, Gino
    Fabozzo, Assunta
    Bianco, Roberto
    Tarantini, Giuseppe
    D'Onofrio, Augusto
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 143 (06): : 1453 - 1455