Predictors of conduction disturbances after transcatheter aortic valve implantation with balloon-expandable valve for bicuspid aortic valve stenosis

被引:3
|
作者
Miyashita, Hirokazu [1 ,2 ]
Moriyama, Noriaki
Yamanaka, Futoshi [3 ]
Saito, Shigeru [3 ]
Lehtola, Heidi [4 ]
Piuhola, Jarkko [4 ]
Niemela, Matti [4 ]
Laine, Mika [1 ,2 ]
机构
[1] Univ Helsinki, Heart & Lung Ctr, Dept Cardiol, Helsinki, Finland
[2] Helsinki Univ Cent Hosp, Helsinki, Finland
[3] Shonan Kamakura Gen Hosp, Dept Cardiol, Kamakura, Kanagawa, Japan
[4] Oulu Univ Hosp, Dept Cardiol, Oulu, Finland
关键词
aortic stenosis; bicuspid aortic valve; conduction disorder; implantation depth; membranous septum length; transcatheter aortic valve replacement; PERMANENT PACEMAKER IMPLANTATION; REPLACEMENT; RISK; OUTCOMES; CALCIFICATION; LENGTH; IMPACT; ROOT;
D O I
10.1111/jce.15525
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Implantation depth and membranous septum (MS) length have been established as the predictors of new-onset conduction disturbance (CD) after transcatheter aortic valve replacement (TAVR) for tricuspid aortic valve (TAV) stenosis. However, little is known about the predictors with bicuspid aortic valve (BAV). This study investigated the role of MS length and implantation depth in predicting CD following TAVR with a balloon-expandable valve in patients with BAV. Methods This retrospective study analyzed 169 patients who underwent TAVR for BAV with balloon-expandable valve, and TAV cohort was established as a control group using propensity score (PS) matching. The primary endpoints were in-hospital new permanent pacemaker implantation (PPI) and new-onset CD (the composite outcome of new-onset left bundle branch block and new PPI). Results PPI developed in 14 patients (8.3%) and new-onset CD in 37 patients (21.9%) in the BAV cohort. Multivariate analysis revealed severe left ventricle outflow tract (LVOT) calcification (odds ratio [OR]: 5.83, 95% confidence interval [CI]: 1.08-31.5, p = .0407) and implantation depth-MS length (OR: 1.30, 95% CI: 1.12-1.51, p = .0005) as the predictors of new-onset CD within the BAV cohort. The matched comparison between BAV and TAV groups showed similar MS length (3.0 vs. 3.2 mm, p = .5307), but valves were implanted more deeply in the BAV group than in the TAV group (3.9 vs. 3.0 mm, p < .0001). New-onset CD was more frequent in patients who had BAV (22.3% vs. 13.9%, p = .0458). Conclusion The implantation depth-MS length, and severe LVOT calcification predicted new-onset CD following TAVR in BAV with balloon-expandable valve. Among BAV patients, THV THV were implanted more deeply compared to THV patients. High deployment technique could be considered to avoid new-onset CD in BAV anatomy.
引用
收藏
页码:1576 / 1586
页数:11
相关论文
共 50 条
  • [11] Conduction Disturbance After Transcatheter Aortic Valve Implantation With Self- or Balloon-Expandable Valve According to the Implantation Depth
    Miyashita, Hirokazu
    Moriyama, Noriaki
    Sugiyama, Yoichi
    Jalanko, Mikko
    Dahlbacka, Sebastian
    Vahasilta, Tommi
    Vainikka, Tiina
    Viikila, Juho
    Laine, Mika
    AMERICAN JOURNAL OF CARDIOLOGY, 2023, 203 : 17 - 22
  • [12] Transcatheter Valve-In-Valve Implantation for Failed Balloon-Expandable Transcatheter Aortic Valves
    Toggweiler, Stefan
    Wood, David A.
    Rodes-Cabau, Josep
    Kapadia, Samir
    Willson, Alexander B.
    Ye, Jian
    Cheung, Anson
    Leipsic, Jonathon
    Binder, Ronald K.
    Gurvitch, Ronen
    Freeman, Melanie
    Thompson, Christopher R.
    Svensson, Lars G.
    Dumont, Eric
    Tuzcu, E. Murat
    Webb, John G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (05) : 571 - 577
  • [13] Balloon-Expandable or Self-Expandable Valves in Valve-in-Valve Transcatheter Aortic Valve Implantation?
    Van Nieuwkerk, Astrid
    Fernandez-Nofrerias, Eduard
    Tchetche, Didier
    Brito, Fabio, Jr.
    Barbanti, Marco
    Kornowski, Ran
    Latib, Azeem
    d'Onofrio, Augusto
    Ribichini, Flavio
    Tello, Vicente Mainar
    Dumonteil, Nicolas
    Baan, Jan
    Abizaid, Alexandre
    Sartori, Samantha
    d'Errigo, Paola
    Tarantini, Giuseppe
    Lunardi, Mattia
    Orvin, Katia
    Pagnesi, Matteo
    Ghattas, Angie
    Dangas, George
    Mehran, Roxana
    Delewi, Ronak
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (19) : B66 - B66
  • [14] Transcatheter aortic valve implantation using balloon-expandable Myval transcatheter heart valve in a patient with bicuspid aortic valve with low-flow, low-gradient severe aortic stenosis
    Adhikari, Chandra Mani
    Bogati, Amrit
    Timalsena, Birat Krishna
    Safi, Md. Sajjad
    Kharel, Sushant
    Thapa, Pratik
    Ghimire, Vijay
    Yadav, Rahul
    Khan, Barkadin
    Prajapati, Dipanker
    NEPALESE HEART JOURNAL, 2024, 21 (02) : 43 - 46
  • [15] FEASIBILITY OF TRANSCATHETER AORTIC VALVE IMPLANTATION IN BICUSPID AORTIC VALVE STENOSIS
    Wood, D. A.
    Wijesinghe, N.
    Nietlispach, F.
    Gurvitch, R.
    Tay, E.
    Rodes-Cabau, J.
    Velianou, J. L.
    Natarajan, M. K.
    Dumont, E.
    Ye, J.
    Leipsic, J.
    Cheung, A.
    Webb, J. G.
    CANADIAN JOURNAL OF CARDIOLOGY, 2010, 26 : 115D - 115D
  • [16] Transcatheter Aortic Valve Implantation in Patients With Bicuspid Aortic Valve Stenosis
    Wijesinghe, Namal
    Ye, Jian
    Rodes-Cabau, Josep
    Cheung, Anson
    Velianou, James L.
    Natarajan, Madhu K.
    Dumont, Eric
    Nietlispach, Fabian
    Gurvitch, Ronen
    Wood, David A.
    Tay, Edgar
    Webb, John G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (11) : 1122 - 1125
  • [17] Incidence and Risk Factors of Hemolysis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve
    Laflamme, Jerome
    Puri, Rishi
    Urena, Marina
    Laflamme, Louis
    DeLarochelliere, Hugo
    Altisent, Omar Abdul-Jawad
    del Trigo, Maria
    Campelo-Parada, Francisco
    DeLarochelliere, Robert
    Paradis, Jean-Michel
    Dumont, Eric
    Doyle, Daniel
    Mohammadi, Siamak
    Cote, Melanie
    Pibarot, Philippe
    Laroche, Vincent
    Rodes-Cabau, Josep
    AMERICAN JOURNAL OF CARDIOLOGY, 2015, 115 (11): : 1574 - 1579
  • [18] Balloon-Expandable Device for Non-Aortic Valve in Valve Transcatheter Heart Valve Implantation
    Williams, Judson
    Sherwood, Matthew M.
    Wang, Andrew
    Gaca, Jeffrey G.
    CARDIOLOGY, 2016, 134 (02) : 239 - 239
  • [19] Repositionable Versus Balloon-Expandable Devices for Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis
    Pilgrim, Thomas
    Stortecky, Stefan
    Nietlispach, Fabian
    Heg, Dik
    Tueller, David
    Toggweiler, Stefan
    Ferrari, Enrico
    Noble, Stephane
    Maisano, Francesco
    Jeger, Raban
    Roffi, Marco
    Gruenenfelder, Juerg
    Huber, Christoph
    Wenaweser, Peter
    Windecker, Stephan
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (11):
  • [20] Balloon-Expandable Valve Geometry After Transcatheter Aortic Valve Replacement in Low-Risk Patients With Bicuspid Versus Tricuspid Aortic Stenosis
    Medranda, Giorgio A.
    Rogers, Toby
    Forrestal, Brian J.
    Case, Brian C.
    Yerasi, Charan
    Chezar-Azerrad, Chava
    Shults, Christian C.
    Torguson, Rebecca
    Shea, Corey
    Parikh, Puja
    Bilfinger, Thomas
    Cocke, Thomas
    Brizzio, Mariano E.
    Levitt, Robert
    Hahn, Chiwon
    Hanna, Nicholas
    Comas, George
    Mahoney, Paul
    Newton, Joseph
    Buchbinder, Maurice
    Zhang, Cheng
    Craig, Paige E.
    Weigold, W. Guy
    Asch, Federico M.
    Weissman, Gaby
    Garcia-Garcia, Hector M.
    Ben-Dor, Itsik
    Satler, Lowell F.
    Waksman, Ron
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2021, 33 : 7 - 12