Predictors of conduction disturbances after transcatheter aortic valve implantation with balloon-expandable valve for bicuspid aortic valve stenosis

被引:3
|
作者
Miyashita, Hirokazu [1 ,2 ]
Moriyama, Noriaki
Yamanaka, Futoshi [3 ]
Saito, Shigeru [3 ]
Lehtola, Heidi [4 ]
Piuhola, Jarkko [4 ]
Niemela, Matti [4 ]
Laine, Mika [1 ,2 ]
机构
[1] Univ Helsinki, Heart & Lung Ctr, Dept Cardiol, Helsinki, Finland
[2] Helsinki Univ Cent Hosp, Helsinki, Finland
[3] Shonan Kamakura Gen Hosp, Dept Cardiol, Kamakura, Kanagawa, Japan
[4] Oulu Univ Hosp, Dept Cardiol, Oulu, Finland
关键词
aortic stenosis; bicuspid aortic valve; conduction disorder; implantation depth; membranous septum length; transcatheter aortic valve replacement; PERMANENT PACEMAKER IMPLANTATION; REPLACEMENT; RISK; OUTCOMES; CALCIFICATION; LENGTH; IMPACT; ROOT;
D O I
10.1111/jce.15525
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Implantation depth and membranous septum (MS) length have been established as the predictors of new-onset conduction disturbance (CD) after transcatheter aortic valve replacement (TAVR) for tricuspid aortic valve (TAV) stenosis. However, little is known about the predictors with bicuspid aortic valve (BAV). This study investigated the role of MS length and implantation depth in predicting CD following TAVR with a balloon-expandable valve in patients with BAV. Methods This retrospective study analyzed 169 patients who underwent TAVR for BAV with balloon-expandable valve, and TAV cohort was established as a control group using propensity score (PS) matching. The primary endpoints were in-hospital new permanent pacemaker implantation (PPI) and new-onset CD (the composite outcome of new-onset left bundle branch block and new PPI). Results PPI developed in 14 patients (8.3%) and new-onset CD in 37 patients (21.9%) in the BAV cohort. Multivariate analysis revealed severe left ventricle outflow tract (LVOT) calcification (odds ratio [OR]: 5.83, 95% confidence interval [CI]: 1.08-31.5, p = .0407) and implantation depth-MS length (OR: 1.30, 95% CI: 1.12-1.51, p = .0005) as the predictors of new-onset CD within the BAV cohort. The matched comparison between BAV and TAV groups showed similar MS length (3.0 vs. 3.2 mm, p = .5307), but valves were implanted more deeply in the BAV group than in the TAV group (3.9 vs. 3.0 mm, p < .0001). New-onset CD was more frequent in patients who had BAV (22.3% vs. 13.9%, p = .0458). Conclusion The implantation depth-MS length, and severe LVOT calcification predicted new-onset CD following TAVR in BAV with balloon-expandable valve. Among BAV patients, THV THV were implanted more deeply compared to THV patients. High deployment technique could be considered to avoid new-onset CD in BAV anatomy.
引用
收藏
页码:1576 / 1586
页数:11
相关论文
共 50 条
  • [1] BALLOON-EXPANDABLE VALVE GEOMETRY AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT IN PATIENTS WITH BICUSPID AORTIC STENOSIS
    Medranda, Giorgio
    Rogers, Toby
    Forrestal, Brian
    Case, Brian
    Yerasi, Charan
    Chezar-Azzerad, Chava
    Shults, Christian
    Torguson, Rebecca
    Shea, Corey
    Parikh, Puja
    Bilfinger, Thomas
    Cocke, Thomas
    Brizzio, Mariano
    Levitt, Robert
    Hahn, Chiwon
    Hanna, Nicholas
    Comas, George
    Zhang, Cheng
    Craig, Paige
    Asch, Federico
    Weissman, Gaby
    Garcia, Hector Garcia
    Ben-Dor, Itsik
    Satler, Lowell
    Waksman, Ron
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 925 - 925
  • [2] Successful implantation of balloon-expandable transcatheter aortic valve against quadricuspid aortic valve stenosis
    Isomatsu, Daisuke
    Oikawa, Masayoshi
    Muto, Yuuki
    Kunii, Hiroyuki
    Takase, Shinya
    Takeishi, Yasuchika
    OXFORD MEDICAL CASE REPORTS, 2024, 2024 (10):
  • [3] Transcatheter Aortic Valve Replacement With a Balloon-expandable Valve for the Treatment of Noncalcified Bicuspid Aortic Valve Disease
    Urena, Marina
    Doyle, Daniel
    Dumont, Eric
    Ribeiro, Henrique Barbosa
    Bilodeau, Sylvie
    Rodes-Cabau, Josep
    REVISTA ESPANOLA DE CARDIOLOGIA, 2014, 67 (04): : 327 - 329
  • [4] A successful transcatheter aortic valve implantation of a balloon-expandable valve for paravalvular leak in a patient with bicuspid aortic valve and horizontal aorta
    Pylko, Anna
    Dabrowski, Maciej
    Chmielak, Zbigniew
    Kukula, Krzysztof
    Witkowski, Adam
    KARDIOLOGIA POLSKA, 2020, 78 (11) : 1187 - 1188
  • [5] Prosthesis depth and conduction disturbances after last generation balloon-expandable transcatheter aortic valve implantation
    Iacovelli, Fortunato
    Pignatelli, Antonio
    Giugliano, Giuseppe
    Stabile, Eugenio
    Cicala, Mariangela
    Salemme, Luigi
    Cioppa, Angelo
    Popusoi, Grigore
    Pucciarelli, Armando
    Verdoliva, Sebastiano
    Bortone, Alessandro Santo
    Losi, Maria-Angela
    Coscioni, Enrico
    Esposito, Giovanni
    Contegiacomo, Gaetano
    Tesorio, Tullio
    EUROPACE, 2018, 20 (01): : 116 - 123
  • [6] Transcatheter aortic valve implantation for bicuspid aortic valve stenosis
    Hamdan, Ashraf
    Kornowski, Ran
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 86 (02) : 331 - 333
  • [7] Transcatheter aortic valve implantation in bicuspid aortic valve stenosis
    Perlman, Gidon Y.
    Blanke, Philipp
    Webb, John G.
    EUROINTERVENTION, 2016, 12 : Y42 - Y45
  • [9] PREDICTORS OF AORTIC ROOT INJURY DURING BALLOON-EXPANDABLE TRANSCATHETER AORTIC VALVE IMPLANTATION
    Barbanti, Marco
    Yang, Tae-Hyun
    Webb, John
    Tamburino, Corrado
    Jilaihawi, Hasan
    Makkar, Raj
    Kodali, Susheel
    Latib, Azeem
    Colombo, Antonio
    Tarantini, Giuseppe
    Raju, Rekha
    Binder, Ronald
    Giang Nguyen
    Freeman, Melanie
    Cabau, Josep Rodes
    Kapadia, Samir
    Min, James
    Feuchtner, Gudrun
    Gurvitch, Ronen
    Alqoofi, Faisal
    Pelletier, Marc
    Napodano, Massimo
    Wood, David
    Leon, Martin
    Leipsic, Jonathon
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1869 - E1869
  • [10] Incidence and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with a balloon-expandable biosprosthesis in patients with bicuspid aortic valves
    Suygun, Hakan
    Kasapkara, Haci Ahmet
    Guney, Murat Can
    Polat, Melike
    Bozkurt, Engin
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2024, 20 (03): : 311 - 318