Potential of Stroke Imaging Using a New Prototype of Low-Field MRI: A Prospective Direct 0.55 T/1.5 T Scanner Comparison

被引:23
|
作者
Rusche, Thilo [1 ]
Breit, Hanns-Christian [1 ]
Bach, Michael [1 ]
Wasserthal, Jakob [1 ]
Gehweiler, Julian [1 ]
Manneck, Sebastian [1 ]
Lieb, Johanna Maria [1 ]
De Marchis, Gian Marco [2 ]
Psychogios, Marios Nikos [1 ]
Sporns, Peter B. [1 ,3 ]
机构
[1] Univ Basel, Univ Hosp Basel, Dept Radiol, Clin Radiol & Nucl Med, CH-4031 Basel, Switzerland
[2] Univ Basel, Univ Hosp Basel, Dept Neurol, CH-4031 Basel, Switzerland
[3] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Neuroradiol, D-20246 Hamburg, Germany
关键词
stroke imaging; low-field MRI; reading study; scanner comparison; GLOBAL BURDEN;
D O I
10.3390/jcm11102798
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Ischemic stroke is a leading cause of mortality and acquired disability worldwide and thus plays an enormous health-economic role. Imaging of choice is computed-tomographic (CT) or magnetic resonance imaging (MRI), especially diffusion-weighted (DW) sequences. However, MR imaging is associated with high costs and therefore has a limited availability leading to low-field-MRI techniques increasingly coming into focus. Thus, the aim of our study was to assess the potential of stroke imaging with low-field MRI. Material and Methods: A scanner comparison was performed including 27 patients (17 stroke cohort, 10 control group). For each patient, a brain scan was performed first with a 1.5T scanner and afterwards with a 0.55T scanner. Scan protocols were as identical as possible and optimized. Data analysis was performed in three steps: All DWI/ADC (apparent diffusion coefficient) and FLAIR (fluid attenuated inversion recovery) sequences underwent Likert rating with respect to image impression, resolution, noise, contrast, and diagnostic quality and were evaluated by two radiologists regarding number and localization of DWI and FLAIR lesions in a blinded fashion. Then segmentation of lesion volumes was performed by two other radiologists on DWI/ADC and FLAIR. Results: DWI/ADC lesions could be diagnosed with the same reliability by the most experienced reader in the 0.55T and 1.5T sequences (specificity 100% and sensitivity 92.9%, respectively). False positive findings did not occur. Detection of number/location of FLAIR lesions was mostly equivalent between 0.55T and 1.5T sequences. No significant difference (p = 0.789-0.104) for FLAIR resolution and contrast was observed regarding Likert scaling. For DWI/ADC noise, the 0.55T sequences were significantly superior (p < 0.026). Otherwise, the 1.5T sequences were significantly superior (p < 0.029). There was no significant difference in infarct volume and volume of infarct demarcation between the 0.55T and 1.5T sequences, when detectable. Conclusions: Low-field MRI stroke imaging at 0.55T may not be inferior to scanners with higher field strengths and thus has great potential as a low-cost alternative in future stroke diagnostics. However, there are limitations in the detection of very small infarcts. Further technical developments with follow-up studies must show whether this problem can be solved.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Extent of brain tumor resection using high-field (1.5-T) versus low-field (0.2-T) intraoperative magnetic resonance imaging
    Bergsneider, M
    Sehati, N
    Villablanca, P
    McArthur, D
    Liau, LM
    NEUROSURGERY, 2004, 55 (02) : 483 - 484
  • [32] Economic aspects of low-field magnetic resonance imaging. Acquisition, installation, and maintenance costs of 0.55 T systems
    Vosshenrich, Jan
    Breit, Hanns-Christian
    Bach, Michael
    Merkle, Elmar M.
    RADIOLOGIE, 2022, 62 (05): : 400 - 404
  • [33] Diffusion weighted mr imaging on a low-field open magnet - Comparison with findings at 1.5T in 18 patients with cerebral ischemia
    Mehdizade, A
    Somon, T
    Wetzel, S
    Kelekis, A
    Martin, JB
    Scheidegger, JR
    Sztajiel, R
    Lovblad, KO
    Ruefenacht, DA
    Delavelle, J
    JOURNAL OF NEURORADIOLOGY, 2003, 30 (01) : 25 - 30
  • [34] Reliability of fast magnetic resonance imaging for acute ischemic stroke patients using a 1.5-T scanner
    Chung, Mi Sun
    Lee, Ji Ye
    Jung, Seung Chai
    Baek, Seunghee
    Shim, Woo Hyun
    Park, Ji Eun
    Kim, Ho Sung
    Choi, Choong Gon
    Kim, Sang Joon
    Lee, Deok Hee
    Jeon, Sang-Beom
    Kang, Dong-Wha
    Kwon, Sun U.
    Kim, Jong S.
    EUROPEAN RADIOLOGY, 2019, 29 (05) : 2641 - 2650
  • [35] Reliability of fast magnetic resonance imaging for acute ischemic stroke patients using a 1.5-T scanner
    Mi Sun Chung
    Ji Ye Lee
    Seung Chai Jung
    Seunghee Baek
    Woo Hyun Shim
    Ji Eun Park
    Ho Sung Kim
    Choong Gon Choi
    Sang Joon Kim
    Deok Hee Lee
    Sang-Beom Jeon
    Dong-Wha Kang
    Sun U. Kwon
    Jong S. Kim
    European Radiology, 2019, 29 : 2641 - 2650
  • [36] Quantification of microemulsion systems using low-field T1-weighted imaging
    Herrera, Delphine
    Chevalier, Thibaud
    Fleury, Marc
    Dalmazzone, Christine
    MAGNETIC RESONANCE IMAGING, 2021, 83 : 160 - 168
  • [37] Characterization of Adrenal Lesions at Chemical-Shift MRI: A Direct Intraindividual Comparison of In- and OpposedPhase Imaging at 1.5 T and 3 T
    Ream, Justin M.
    Gaing, Byron
    Mussi, Thais C.
    Rosenkrantz, Andrew B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) : 536 - 541
  • [38] Comparing Metal Artifact Severity and Ability to Assess Near-Metal Anatomy Between 0.55 T and 1.5 T MRI in Patients with Metallic Spinal Implants-A Scanner Comparison Study
    Seifert, Alina Carolin
    Breit, Hanns-Christian
    Schlicht, Felix
    Donners, Ricardo
    Harder, Dorothee
    Vosshenrich, Jan
    ACADEMIC RADIOLOGY, 2024, 31 (06) : 2456 - 2463
  • [39] Cost comparison analysis of low-field (0.23 T) MRI- and CT-guided bone biopsies
    Alanen, J
    Keski-Nisula, L
    Blanco-Sequeiros, R
    Tervonen, O
    EUROPEAN RADIOLOGY, 2004, 14 (01) : 123 - 128
  • [40] Cost comparison analysis of low-field (0.23 T) MRI- and CT-guided bone biopsies
    J. Alanen
    L. Keski-Nisula
    R. Blanco-Sequeiros
    O. Tervonen
    European Radiology, 2004, 14 : 123 - 128