Potential of Stroke Imaging Using a New Prototype of Low-Field MRI: A Prospective Direct 0.55 T/1.5 T Scanner Comparison

被引:23
|
作者
Rusche, Thilo [1 ]
Breit, Hanns-Christian [1 ]
Bach, Michael [1 ]
Wasserthal, Jakob [1 ]
Gehweiler, Julian [1 ]
Manneck, Sebastian [1 ]
Lieb, Johanna Maria [1 ]
De Marchis, Gian Marco [2 ]
Psychogios, Marios Nikos [1 ]
Sporns, Peter B. [1 ,3 ]
机构
[1] Univ Basel, Univ Hosp Basel, Dept Radiol, Clin Radiol & Nucl Med, CH-4031 Basel, Switzerland
[2] Univ Basel, Univ Hosp Basel, Dept Neurol, CH-4031 Basel, Switzerland
[3] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Neuroradiol, D-20246 Hamburg, Germany
关键词
stroke imaging; low-field MRI; reading study; scanner comparison; GLOBAL BURDEN;
D O I
10.3390/jcm11102798
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Ischemic stroke is a leading cause of mortality and acquired disability worldwide and thus plays an enormous health-economic role. Imaging of choice is computed-tomographic (CT) or magnetic resonance imaging (MRI), especially diffusion-weighted (DW) sequences. However, MR imaging is associated with high costs and therefore has a limited availability leading to low-field-MRI techniques increasingly coming into focus. Thus, the aim of our study was to assess the potential of stroke imaging with low-field MRI. Material and Methods: A scanner comparison was performed including 27 patients (17 stroke cohort, 10 control group). For each patient, a brain scan was performed first with a 1.5T scanner and afterwards with a 0.55T scanner. Scan protocols were as identical as possible and optimized. Data analysis was performed in three steps: All DWI/ADC (apparent diffusion coefficient) and FLAIR (fluid attenuated inversion recovery) sequences underwent Likert rating with respect to image impression, resolution, noise, contrast, and diagnostic quality and were evaluated by two radiologists regarding number and localization of DWI and FLAIR lesions in a blinded fashion. Then segmentation of lesion volumes was performed by two other radiologists on DWI/ADC and FLAIR. Results: DWI/ADC lesions could be diagnosed with the same reliability by the most experienced reader in the 0.55T and 1.5T sequences (specificity 100% and sensitivity 92.9%, respectively). False positive findings did not occur. Detection of number/location of FLAIR lesions was mostly equivalent between 0.55T and 1.5T sequences. No significant difference (p = 0.789-0.104) for FLAIR resolution and contrast was observed regarding Likert scaling. For DWI/ADC noise, the 0.55T sequences were significantly superior (p < 0.026). Otherwise, the 1.5T sequences were significantly superior (p < 0.029). There was no significant difference in infarct volume and volume of infarct demarcation between the 0.55T and 1.5T sequences, when detectable. Conclusions: Low-field MRI stroke imaging at 0.55T may not be inferior to scanners with higher field strengths and thus has great potential as a low-cost alternative in future stroke diagnostics. However, there are limitations in the detection of very small infarcts. Further technical developments with follow-up studies must show whether this problem can be solved.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] More Space, Less Noise-New-generation Low-Field Magnetic Resonance Imaging Systems Can Improve Patient Comfort: A Prospective 0.55T-1.5T-Scanner Comparison
    Rusche, Thilo
    Vosshenrich, Jan
    Winkel, David J.
    Donners, Ricardo
    Segeroth, Martin
    Bach, Michael
    Merkle, Elmar M.
    Breit, Hanns-Christian
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (22)
  • [2] Diagnostic abdominal MR imaging on a prototype low-field 0.55 T scanner operating at two different gradient strengths
    Hersh Chandarana
    Barun Bagga
    Chenchan Huang
    Bari Dane
    Robert Petrocelli
    Mary Bruno
    Mahesh Keerthivasan
    David Grodzki
    Kai Tobias Block
    David Stoffel
    Daniel K. Sodickson
    Abdominal Radiology, 2021, 46 : 5772 - 5780
  • [3] Low-field 0.55 T MRI evaluation of the fetus
    Skorn Ponrartana
    HaiThuy N. Nguyen
    Sophia X. Cui
    Ye Tian
    Prakash Kumar
    John C. Wood
    Krishna S. Nayak
    Pediatric Radiology, 2023, 53 : 1469 - 1475
  • [4] Diagnostic abdominal MR imaging on a prototype low-field 0.55 T scanner operating at two different gradient strengths
    Chandarana, Hersh
    Bagga, Barun
    Huang, Chenchan
    Dane, Bari
    Petrocelli, Robert
    Bruno, Mary
    Keerthivasan, Mahesh
    Grodzki, David
    Block, Kai Tobias
    Stoffel, David
    Sodickson, Daniel K.
    ABDOMINAL RADIOLOGY, 2021, 46 (12) : 5772 - 5780
  • [5] Low-field 0.55 T MRI evaluation of the fetus
    Ponrartana, Skorn
    Nguyen, HaiThuy N.
    Cui, Sophia X.
    Tian, Ye
    Kumar, Prakash
    Wood, John C.
    Nayak, Krishna S.
    PEDIATRIC RADIOLOGY, 2023, 53 (07) : 1469 - 1475
  • [6] Wearable Sensing in Low-Field (0.55 T) MRI Environment
    Munoz, Felix
    Nayak, Krishna S.
    Khan, Yasser
    IEEE SENSORS LETTERS, 2025, 9 (02)
  • [7] Lung Nodule Detection With Modern Low-Field MRI (0.55 T) in Comparison to CT
    Hinsen, Maximilian
    Nagel, Armin M.
    May, Matthias S.
    Wiesmueller, Marco
    Uder, Michael
    Heiss, Rafael
    INVESTIGATIVE RADIOLOGY, 2024, 59 (03) : 215 - 222
  • [8] New low-field extremity MRI, compacTscan: comparison with whole-body 1.5 T conventional MRI
    Suzuki, Takeshi
    Ito, Satoshi
    Handa, Shinya
    Kose, Katsumi
    Okamoto, Yoshikazu
    Minami, Manabu
    Sugihara, Makoto
    Horikoshi, Masanobu
    Tsuboi, Hiroto
    Hayashi, Taichi
    Goto, Daisuke
    Matsumoto, Isao
    Sumida, Takayuki
    MODERN RHEUMATOLOGY, 2010, 20 (04) : 331 - 336
  • [9] Image Quality of Lumbar Spine Imaging at 0.55T Low-Field MRI is Comparable to Conventional 1.5T MRI - Initial Observations in Healthy Volunteers
    Breit, Hanns-Christian
    Vosshenrich, Jan
    Hofmann, Verena
    Rusche, Thilo
    Kovacs, Balazs K.
    Bach, Michael
    Manneck, Sebastian
    Harder, Dorothee
    ACADEMIC RADIOLOGY, 2023, 30 (11) : 2440 - 2446
  • [10] T2* relaxometry of fetal brain structures using low-field (0.55T) MRI
    Payette, Kelly
    Uus, Alena U.
    Kollstad, Ella
    Verdera, Jordina Aviles
    Gallo, Dario
    Hall, Megan
    Hajnal, Joseph V.
    Rutherford, Mary A.
    Story, Lisa
    Hutter, Jana
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (05) : 1942 - 1953