摘要
Introduction: Biokinetic and dosimetry studies in small animals often precede clinical radionuclide therapies. As in human studies, a reliable evaluation of therapeutic efficacy is essential and must be based on accurate dosimetry, which must be based on a realistic dosimetry model. The aim of this study was to evaluate the differences in the results when using a more anatomic realistic mouse phantom, as compared to previously mathematically described phantoms, based mainly on ellipsoids and cylinders. The difference in results from the two Monte Carlo codes, EGS4 and MCNPX 2.6a, was also evaluated. Methods: An anatomical correct mouse phantom (Moby) was developed by Segars et al. for the evaluation and optimization of the in vivo imaging of mice. The Moby phantom is based on surfaces, which allows for an easy and flexible definition of organ sizes. It includes respiratory movements and a beating heart. It also allows for a redefinition of the location of several internal organs. The execution of he Moby program generates a three-dimensional voxel-based phantom of a specified size, which was modified and used as input for Monte Carlo simulations of absorbed fractions and S-factors. The radiation transport was simulated both with the EGS4 system and the MCNPX 2.6a code. Calculations were done,for the radionuclides F-18, I-124, I-131, In-111, Lu-177, and Y-90. S-factors were calculated using in-house-developed IDL programs and compared with results from previously published models. Results: The comparison of S-factors obtained by the Moby model and mathematical phantoms showed that these, in many cases, were within the same range, whereas for some organs, they were underestimated in the mathematical phantoms. The results were closer to the more anatomically realistic phantom than to the mathematical phantoms, with some exceptions. When investing differences between MCNPX 2.6a and EGS4 using the Moby phantom, results indicated some differences in absorbed fractions for electrons. This reason may be owing to differences in the codes regarding the theory for which electron transport are simulated. Conclusions: It is possible to calculate S-factors that are specific for small animals, such as mice. The Moby phantom is useful as a dosimetry model because it is anatomically realistic, but still very flexible, with 35 accurately segmented regions.
引用
收藏
页码:438 / 442
页数:5
相关论文
共 50 条
  • [31] Statistical Phantoms and Determining the Uncertainty of the Thyroid Mathematical Phantom in Internal Dosimetry Using the Monte Carlo Method
    Vahid Ragheb
    Zahra Sajjadi
    Saeed Mohammadi
    Journal of the Korean Physical Society, 2020, 77 : 1075 - 1081
  • [32] Comparison of adjoint and forward Monte Carlo based treatment planning for a realistic head phantom
    Nievaart, S.
    Moss, R.
    Wittig, A.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : S115 - S117
  • [33] NEW METHOD BASED ON MONTE CARLO CALCULATION AND VOXELIZED PHANTOMS FOR REALISTIC INTERNAL DOSIMETRY: APPLICATION TO A COMPLEX AND OLD ACTINIDE CONTAMINATION
    Broggio, D.
    Janeczko, J.
    Lamart, S.
    Blanchardon, E.
    Borisov, N.
    Molokanov, A.
    Yatsenko, V.
    Franck, D.
    NUCLEAR TECHNOLOGY, 2009, 168 (03) : 824 - 831
  • [34] Voxel-based mouse model for internal dose calculations using Monte Carlo simulations (MCNP)
    Bitar, A.
    Lisbona, A.
    Thedrez, P.
    Maurel, C. Sai
    Le Forestier, D.
    Bardies, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S110 - S110
  • [35] Monte Carlo simulations of absorbed dose in a mouse phantom from 18-fluorine compounds
    Taschereau, Richard
    Chatziioannou, Arion F.
    MEDICAL PHYSICS, 2007, 34 (03) : 1026 - 1036
  • [36] PARaDIM-A PHITS-based Monte Carlo tool for internal dosimetry
    Carter, Lukas
    Crawford, Troy
    Sato, Tatsuhiko
    Furuta, Takuya
    Bolch, Wesley
    Brown, Justin
    Kim, Chan
    Choi, Chansoo
    Lewis, Jason
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2019, 62 : S512 - S514
  • [37] Measurement Based Source Model for On-Board Imager Monte Carlo Dosimetry Simulations
    McMillan, K.
    Michailian, A.
    McNitt-Gray, M.
    Ruan, D.
    MEDICAL PHYSICS, 2012, 39 (06) : 4000 - 4001
  • [38] Innovations in Computer Technologies Have Impacted Radiation Dosimetry Through Anatomically Realistic Phantoms and Fast Monte Carlo Simulations
    Xu, X. George
    HEALTH PHYSICS, 2019, 116 (02): : 263 - 275
  • [39] Application of a pelvic phantom in brachytherapy dosimetry for high-dose-rate (HDR) 192Ir source based on Monte Carlo simulations
    Ahn, Woo Sang
    Choi, Wonsik
    Shin, Seong Soo
    Jung, Jinhong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (04) : 557 - 564
  • [40] Application of a pelvic phantom in brachytherapy dosimetry for high-dose-rate (HDR) 192Ir source based on Monte Carlo simulations
    Woo Sang Ahn
    Wonsik Choi
    Seong Soo Shin
    Jinhong Jung
    Journal of the Korean Physical Society, 2014, 65 : 557 - 564