Mouse S-factors based on monte carlo simulations in the anatomical realistic Moby phantom for internal dosimetry

被引:37
|
作者
Larsson, Erik [1 ]
Strand, Sven-Erik [1 ]
Ljungberg, Michael [1 ]
Jonsson, Bo-Anders [1 ]
机构
[1] Lund Univ, Dept Clin Sci, SE-22185 Lund, Sweden
关键词
small animal dosimetry; mouse phantom; Moby; Monte Carlo; S factors; absorbed fractions; MCNPX;
D O I
10.1089/cbr.2006.320
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Biokinetic and dosimetry studies in small animals often precede clinical radionuclide therapies. As in human studies, a reliable evaluation of therapeutic efficacy is essential and must be based on accurate dosimetry, which must be based on a realistic dosimetry model. The aim of this study was to evaluate the differences in the results when using a more anatomic realistic mouse phantom, as compared to previously mathematically described phantoms, based mainly on ellipsoids and cylinders. The difference in results from the two Monte Carlo codes, EGS4 and MCNPX 2.6a, was also evaluated. Methods: An anatomical correct mouse phantom (Moby) was developed by Segars et al. for the evaluation and optimization of the in vivo imaging of mice. The Moby phantom is based on surfaces, which allows for an easy and flexible definition of organ sizes. It includes respiratory movements and a beating heart. It also allows for a redefinition of the location of several internal organs. The execution of he Moby program generates a three-dimensional voxel-based phantom of a specified size, which was modified and used as input for Monte Carlo simulations of absorbed fractions and S-factors. The radiation transport was simulated both with the EGS4 system and the MCNPX 2.6a code. Calculations were done,for the radionuclides F-18, I-124, I-131, In-111, Lu-177, and Y-90. S-factors were calculated using in-house-developed IDL programs and compared with results from previously published models. Results: The comparison of S-factors obtained by the Moby model and mathematical phantoms showed that these, in many cases, were within the same range, whereas for some organs, they were underestimated in the mathematical phantoms. The results were closer to the more anatomically realistic phantom than to the mathematical phantoms, with some exceptions. When investing differences between MCNPX 2.6a and EGS4 using the Moby phantom, results indicated some differences in absorbed fractions for electrons. This reason may be owing to differences in the codes regarding the theory for which electron transport are simulated. Conclusions: It is possible to calculate S-factors that are specific for small animals, such as mice. The Moby phantom is useful as a dosimetry model because it is anatomically realistic, but still very flexible, with 35 accurately segmented regions.
引用
收藏
页码:438 / 442
页数:5
相关论文
共 50 条
  • [21] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    Kaddouch, S.
    El Khayati, N.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2017, 72 (06) : 658 - 662
  • [22] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    S. Kaddouch
    N. El Khayati
    Moscow University Physics Bulletin, 2017, 72 : 658 - 662
  • [23] Assessment of PCXMC Monte Carlo simulations in slot-scanning-based examinations: comparison with in-phantom thermoluminescent dosimetry
    Piai, A.
    Loria, A.
    Tiberio, P.
    Magnino, S.
    Campoleoni, M.
    Sconfienza, L. M.
    Del Vecchio, A.
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (03) : 277 - 289
  • [24] A Monte Carlo study of cellular S-factors for 1 keV to 1 MeV electrons
    Bousis, C.
    Emfietzoglou, D.
    Hadjidoukas, P.
    Nikjoo, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (16): : 5023 - 5038
  • [25] Subcellular S-factors for low-energy electrons: A comparison of Monte Carlo simulations and continuous-slowing-down calculations
    Emfietzoglou, D.
    Kostarelos, K.
    Hadjidoukas, P.
    Bousis, C.
    Fotopoulos, A.
    Pathak, A.
    Nikjoo, H.
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2008, 84 (12) : 1034 - 1044
  • [26] A voxel-based mouse for internal dose calculations using Monte Carlo simulations (MCNP)
    Bitar, A.
    Lisbona, A.
    Thedrez, P.
    Maurel, C. Sai
    Le Forestier, D.
    Barbet, J.
    Bardies, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (04): : 1013 - 1025
  • [27] Dosimetry for Norwegian rats based on Monte Carlo simulations using a realistic rat phantom and kinetics for 177Lu-and 90Y-BR96 monoclonal antibodies
    Larsson, Erik
    Ljungberg, Michael
    Segars, William
    Martensson, Linda
    Nilsson, Rune
    Tennvall, Jan
    Strand, Sven
    Jonsson, Bo
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [28] MONTE CARLO SIMULATIONS OF THE ELECTRIC FIELD CLOSE TO THE BODY IN REALISTIC ENVIRONMENTS FOR APPLICATION IN PERSONAL RADIOFREQUENCY DOSIMETRY
    Iskra, S.
    McKenzie, R.
    Cosic, I.
    RADIATION PROTECTION DOSIMETRY, 2011, 147 (04) : 517 - 527
  • [29] Statistical Phantoms and Determining the Uncertainty of the Thyroid Mathematical Phantom in Internal Dosimetry Using the Monte Carlo Method
    Ragheb, Vahid
    Sajjadi, Zahra
    Mohammadi, Saeed
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 77 (12) : 1075 - 1081
  • [30] Canine Anatomic Voxel Phantom for Internal Dosimetry: Comparison between Monte-Carlo and Convolution Method
    Moreau, M.
    Govignon, A.
    Mauxion, T.
    Fusellier, M.
    Abadie, J.
    Bardies, M.
    Hindorf, C.