Mouse S-factors based on monte carlo simulations in the anatomical realistic Moby phantom for internal dosimetry

被引:37
|
作者
Larsson, Erik [1 ]
Strand, Sven-Erik [1 ]
Ljungberg, Michael [1 ]
Jonsson, Bo-Anders [1 ]
机构
[1] Lund Univ, Dept Clin Sci, SE-22185 Lund, Sweden
关键词
small animal dosimetry; mouse phantom; Moby; Monte Carlo; S factors; absorbed fractions; MCNPX;
D O I
10.1089/cbr.2006.320
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Biokinetic and dosimetry studies in small animals often precede clinical radionuclide therapies. As in human studies, a reliable evaluation of therapeutic efficacy is essential and must be based on accurate dosimetry, which must be based on a realistic dosimetry model. The aim of this study was to evaluate the differences in the results when using a more anatomic realistic mouse phantom, as compared to previously mathematically described phantoms, based mainly on ellipsoids and cylinders. The difference in results from the two Monte Carlo codes, EGS4 and MCNPX 2.6a, was also evaluated. Methods: An anatomical correct mouse phantom (Moby) was developed by Segars et al. for the evaluation and optimization of the in vivo imaging of mice. The Moby phantom is based on surfaces, which allows for an easy and flexible definition of organ sizes. It includes respiratory movements and a beating heart. It also allows for a redefinition of the location of several internal organs. The execution of he Moby program generates a three-dimensional voxel-based phantom of a specified size, which was modified and used as input for Monte Carlo simulations of absorbed fractions and S-factors. The radiation transport was simulated both with the EGS4 system and the MCNPX 2.6a code. Calculations were done,for the radionuclides F-18, I-124, I-131, In-111, Lu-177, and Y-90. S-factors were calculated using in-house-developed IDL programs and compared with results from previously published models. Results: The comparison of S-factors obtained by the Moby model and mathematical phantoms showed that these, in many cases, were within the same range, whereas for some organs, they were underestimated in the mathematical phantoms. The results were closer to the more anatomically realistic phantom than to the mathematical phantoms, with some exceptions. When investing differences between MCNPX 2.6a and EGS4 using the Moby phantom, results indicated some differences in absorbed fractions for electrons. This reason may be owing to differences in the codes regarding the theory for which electron transport are simulated. Conclusions: It is possible to calculate S-factors that are specific for small animals, such as mice. The Moby phantom is useful as a dosimetry model because it is anatomically realistic, but still very flexible, with 35 accurately segmented regions.
引用
收藏
页码:438 / 442
页数:5
相关论文
共 50 条
  • [1] S factors for small animal dosimetry based on Monte Carlo simulations of an anatomical realistic mouse phantom
    Larsson, E.
    Strand, S.
    Ljungberg, M.
    Jonsson, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S173 - S173
  • [2] Development of a Hybrid Multiscale Phantom for Monte Carlo Based Internal Dosimetry
    Marcatili, S.
    Villoing, D.
    Bardies, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S160 - S161
  • [3] Monte Carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom
    Taschereau, R
    Chow, PL
    Chatziioannou, AF
    MEDICAL PHYSICS, 2006, 33 (01) : 216 - 224
  • [4] Optimized Monte Carlo simulations for voxel-based internal dosimetry
    Cordeiro, Leanderson P.
    de Sa, Lidia, V
    Kitamikado, Rafael A.
    Sapienza, Marcelo T.
    Bonifacio, Daniel A. B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11):
  • [5] Monte Carlo simulations for external neutron dosimetry based on the visible Chinese human phantom
    Zhang, Guozhi
    Liu, Qian
    Luo, Qingming
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (24): : 7367 - 7383
  • [6] FDG-PET image-based dose distribution in a realistic mouse phantom from Monte Carlo simulations
    Taschereau, Richard
    Chatziioannou, Arion F.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1633 - 1636
  • [7] Monte Carlo calculations of absorbed doses in tumours using a modified MOBY mouse phantom for pre-clinical dosimetry studies
    Larsson, Erik
    Ljungberg, Michael
    Strand, Sven-Erik
    Jonsson, Bo-Anders
    ACTA ONCOLOGICA, 2011, 50 (06) : 973 - 980
  • [8] Monte-Carlo validation of a dosimetric mouse model based on an advanced version of the digital phantom moby
    Mauxion, T.
    Suhard, J.
    Barbet, J.
    Bardies, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S200 - S200
  • [9] Monte Carlo and experimental internal radionuclide dosimetry in RANDO head phantom
    Ruhollah Ghahraman Asl
    Shahrokh Nasseri
    Ali Asghar Parach
    Seyed Rasoul Zakavi
    Mehdi Momennezhad
    David Davenport
    Australasian Physical & Engineering Sciences in Medicine, 2015, 38 : 465 - 472
  • [10] Monte Carlo and experimental internal radionuclide dosimetry in RANDO head phantom
    Asl, Ruhollah Ghahraman
    Nasseri, Shahrokh
    Parach, Ali Asghar
    Zakavi, Seyed Rasoul
    Momennezhad, Mehdi
    Davenport, David
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (03) : 465 - 472