Oscillator-Based Reactance Sensors With Injection Locking for High-Throughput Flow Cytometry Using Microwave Dielectric Spectroscopy

被引:68
|
作者
Chien, Jun-Chau [1 ]
Niknejad, Ali M. [1 ,2 ]
机构
[1] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Berkeley, CA 94720 USA
[2] Berkeley Wireless Res Ctr BWRC, Berkeley, CA USA
关键词
Capacitive sensor; dielectric spectroscopy; flow cytometry; injection-locked oscillators (ILOs); interferometry; microfluidics; nested chopping; permittivity; PHASE NOISE; IMPEDANCE CYTOMETRY; CHEMICAL SENSOR; COUPLED QVCO; SINGLE; CELLS; ARRAY;
D O I
10.1109/JSSC.2015.2500362
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the analysis and design of oscillator-based reactance sensors employing injection locking for high-throughput label-free single-cell analysis using dielectric spectroscopy at microwave frequencies. By injection-locking two sensing LC-oscillators with an I/Q excitation source, the measurement of the sample-induced frequency shift caused by the interaction with the electromagnetic fields is performed through phase detection with injection-strength-dependent transducer gain. Such inherent phase amplification offered by the injection locking not only relaxes the design requirement for the readout circuits but also maintains the highest rejection against common-mode errors associated with the drift of the supply voltage and the environmental parameters. To reduce flicker noise contribution, a chopping technique employing phase modulation is exploited. In addition, this paper presents a novel ping-pong chopping approach to alleviate chopping-induced dc offset. In this prototype, four sensing channels, covering frequencies between 6.5 and 30 GHz, are distributed along a microfluidic channel fabricated with standard photolithography. Measurements show that the proposed microwave capacitive sensors achieve a sub-aF(rms) of noise sensitivity at 100 kHz filtering bandwidth, enabling measurement throughput exceeding 1 k cells/s. The sensor prototype is implemented in 65 nm CMOS technology and consumes 65 mW at 1 V supply.
引用
收藏
页码:457 / 472
页数:16
相关论文
共 50 条
  • [21] Rapid, high-throughput phenotypic profiling of endosymbiotic dinoflagellates (Symbiodiniaceae) using benchtop flow cytometry
    Anthony, Colin Jeffrey
    Lock, Colin
    Bentlage, Bastian
    PLOS ONE, 2023, 18 (09):
  • [22] A multifunctional androgen receptor screening assay using the high-throughput HyperCyt® flow cytometry system
    Dennis, Megan K.
    Bowles, Harmony J. C.
    MacKenzie, Debra A.
    Burchiel, Scott W.
    Edwards, Bruce S.
    Sldar, Larry A.
    Prossnitz, Eric R.
    Thompson, Todd A.
    CYTOMETRY PART A, 2008, 73A (05) : 390 - 399
  • [23] Label Free Identification of Peripheral Blood Eosinophils Using High-Throughput Imaging Flow Cytometry
    Piasecka, Justyna
    Hennig, Holger
    Theis, Fabian J.
    Rees, Paul
    Summers, Huw D.
    Thornton, Catherine A.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2017, 139 (02) : AB163 - AB163
  • [24] Protocol for high-throughput compound screening using flow cytometry in THP-1 cells
    Spangenberg, Stephan H.
    Zavareh, Reza Beheshti
    Lairson, Luke L.
    STAR PROTOCOLS, 2021, 2 (02):
  • [25] Multiparametric Profiling of Neutrophil Function via a High-Throughput Flow Cytometry-Based Assay
    Timmer, Kyle D.
    Floyd, Daniel J.
    Scherer, Allison K.
    Crossen, Arianne J.
    Atallah, Johnny
    Viens, Adam L.
    Sykes, David B.
    Mansour, Michael K.
    CELLS, 2023, 12 (05)
  • [26] High-throughput flow cytometry-based assay to identify apoptosis-inducing proteins
    Sauermann, Mamatha
    Hahne, Florian
    Schmidt, Christian
    Majety, Meher
    Rosenfelder, Heiko
    Bechtel, Stephanie
    Huber, Wolfgang
    Poustka, Annemarie
    Arlt, Dorit
    Wiemann, Stefan
    JOURNAL OF BIOMOLECULAR SCREENING, 2007, 12 (04) : 510 - 520
  • [27] A high-throughput 3-parameter flow cytometry-based cell death assay
    Buenz, Eric J.
    Limburg, Paul J.
    Howe, Charles L.
    CYTOMETRY PART A, 2007, 71A (03) : 170 - 173
  • [28] Development of a high-throughput γ-H2AX assay based on imaging flow cytometry
    Younghyun Lee
    Qi Wang
    Igor Shuryak
    David J. Brenner
    Helen C. Turner
    Radiation Oncology, 14
  • [29] Development of a high-throughput γ-H2AX assay based on imaging flow cytometry
    Lee, Younghyun
    Wang, Qi
    Shuryak, Igor
    Brenner, David J.
    Turner, Helen C.
    RADIATION ONCOLOGY, 2019, 14 (01)
  • [30] A Flow Cytometry-Based High-Throughput Technique for Screening Integrin-Inhibitory Drugs
    Cao, Ziming
    Garcia, Matthew J.
    Sklar, Larry A.
    Wandinger-Ness, Angela
    Fan, Zhichao
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (204):