Spinal navigation for minimally invasive thoracic and lumbosacral spine fixation: implications for radiation exposure, operative time, and accuracy of pedicle screw placement

被引:67
|
作者
Tajsic, T. [1 ]
Patel, K. [1 ]
Farmer, R. [2 ]
Mannion, R. J. [1 ]
Trivedi, R. A. [1 ]
机构
[1] Cambridge Univ Hosp NHS Fdn Trust, Div Neurosurg, Hills Rd,Box 167, Cambridge CB2 0QQ, England
[2] Cambridge Univ Hosp NHS Fdn Trust, Dept Radiol, Cambridge, England
关键词
Minimally invasive (MIS) spinal fixation; 2D fluoroscopy; 3D fluoroscopy; Spinal navigation; C-Arm; O-Arm; IMAGE GUIDANCE; LUMBAR SPINE; ASSISTED FLUOROSCOPY; SURGERY; SYSTEM; INSERTION; OUTCOMES; FUSION;
D O I
10.1007/s00586-018-5587-z
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Navigation is emerging as a useful adjunct in percutaneous, minimally invasive spinal surgery (MIS). The aim of this study was to compare C-Arm navigated, O-Arm navigated and conventional 2D-fluoroscopy assisted MIS thoracic and lumbosacral spine fixation techniques in terms of operating time, radiation exposure and accuracy of pedicle screw (PS) placement. Retrospective observational study of 152 consecutive adults who underwent MIS fixations for spinal instability: 96 2D-fluoroscopy assisted, 39 3D-C-Arm navigated and 27 using O-Arm navigated. O-Arm navigation significantly reduced PS misplacement (1.23%, p) compared to 3D-C-Arm navigation (7.29%, p = 0.0082) and 2D-fluoro guided placement (5.16%, p = 0379). 3D-C-Arm navigation was associated with lower procedural radiation exposure of the patient (0.4 mSv) than O-Arm navigation (3.24 mSv) or 2D-fluoro guidance (1.5 mSv). Operative time was comparable between three modalities. O-Arm navigation provides greater accuracy of percutaneous instrumentation placement with an acceptable procedural radiation dose delivered to the patients and comparable operative times. These slides can be retrieved under Electronic Supplementary material. [GRAPHICS] .
引用
收藏
页码:1918 / 1924
页数:7
相关论文
共 50 条
  • [11] The XVS System During Open Spinal Fixation Procedures in Patients Requiring Pedicle Screw Placement in the Lumbosacral Spine
    Harel, Ran
    Anekstein, Yoram
    Raichel, Michael
    Molina, Camilo A.
    Ruiz-Cardozo, Miguel A.
    Orru, Emanuele
    Khan, Majid
    Mirovsky, Yigal
    Smorgick, Yossi
    WORLD NEUROSURGERY, 2022, 164 : E1226 - E1232
  • [12] REDUCTION IN PEDICLE SCREW PLACEMENT TIME WITH A NOVEL GUIDEWIRELESS PEDICLE SCREW SYSTEM FOR MINIMALLY INVASIVE SPINE SURGERY: INITIAL FINDINGS
    Grossi, P.
    Badin, M.
    Erb, M.
    Cirilli, L.
    Malone, D.
    Walsh, M.
    Menzie, A. M.
    Bhattacharyya, S. K.
    VALUE IN HEALTH, 2019, 22 : S223 - S223
  • [13] Implications of navigation in thoracolumbar pedicle screw placement on screw accuracy and screw diameter/pedicle width ratio
    Mandelka, Eric
    Gierse, Jula
    Zimmermann, Felix
    Gruetzner, Paul A.
    Franke, Jochen
    Vetter, Sven Y.
    BRAIN AND SPINE, 2023, 3
  • [14] Navigated robotic assistance improves pedicle screw accuracy in minimally invasive surgery of the lumbosacral spine: 600 pedicle screws in a single institution
    Wallace, David J.
    Vardiman, Arnold B.
    Booher, Grant A.
    Crawford, Neil R.
    Riggleman, Jessica R.
    Greeley, Samantha L.
    Ledonio, Charles G.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2020, 16 (01):
  • [15] Augmented Reality Spine Surgery Navigation Increasing Pedicle Screw Insertion Accuracy for Both Open and Minimally Invasive Spine Surgeries
    Felix, Brent
    Kalatar, Seyed Babak
    Moatz, Bradley
    Hofstetter, Christoph
    Karsy, Michael
    Parr, Ryan
    Gibby, Wendell
    SPINE, 2022, 47 (12) : 865 - 872
  • [16] Minimally invasive posterior percutaneous pedicle screw fixation for instability of spinal metastases
    Jiang, Weigang
    Cao, Xuyong
    Liu, Yaosheng
    Qin, Haifeng
    Fan, Haitao
    Liu, Shubin
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (05): : 5359 - 5366
  • [17] Reduction in Radiation Exposure in Minimally Invasive Pedicle Screw Placement Using a Tubular Retractor: A Pilot Study
    Oki, Takeshi
    Lefor, Alan Kawarai
    Nakamura, Kentaro
    Higashi, Takahiro
    Oki, Isao
    TOMOGRAPHY, 2023, 9 (01) : 12 - 24
  • [18] Minimally invasive percutaneous transpedicular screw fixation: increased accuracy and reduced radiation exposure by means of a novel electromagnetic navigation system
    von Jako, Ron
    Finn, Michael A.
    Yonemura, Kenneth S.
    Araghi, Ali
    Khoo, Larry T.
    Carrino, John A.
    Perez-Cruet, Mick
    ACTA NEUROCHIRURGICA, 2011, 153 (03) : 589 - 596
  • [19] Minimally invasive percutaneous transpedicular screw fixation: increased accuracy and reduced radiation exposure by means of a novel electromagnetic navigation system
    Ron von Jako
    Michael A. Finn
    Kenneth S. Yonemura
    Ali Araghi
    Larry T. Khoo
    John A. Carrino
    Mick Perez-Cruet
    Acta Neurochirurgica, 2011, 153 : 589 - 596
  • [20] How safe is minimally invasive pedicle screw placement for treatment of thoracolumbar spine fractures?
    Heintel, Timo Michael
    Dannigkeit, Stefan
    Fenwick, Annabel
    Jordan, Martin Cornelius
    Jansen, Hendrik
    Gilbert, Fabian
    Meffert, Rainer
    EUROPEAN SPINE JOURNAL, 2017, 26 (05) : 1515 - 1524