Evaluation of GAFCHROMIC® EBT film for CyberKnife® dosimetry

被引:111
|
作者
Wilcox, Ellen E. [1 ]
Daskalov, George M. [1 ]
机构
[1] St Francis Hosp & Med Ctr, Dept Radiat Oncol, Hartford, CT 06105 USA
关键词
EBT film dosimetry; stereotactic radiosurgery;
D O I
10.1118/1.2734384
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
External beam therapy (EBT) GAFCHROMIC (R) film is evaluated for dosimetry and characterization of the CyberKnife (R) radiation beams. Percentage depth doses, lateral beam profiles, and output factors are measured in solid water using EBT GAFCHROMIC (R) film (International Specialty Products, Wayne, NJ) for the 6 MV radiation beams of diameter 5 to 60 rum produced by the CyberKnife (R) (Accuray, Sunnyvale, CA). The data are compared to those measured with the PTW 60008 diode and the Wellhofer CC01 ion chamber in water. For the small radiation field sizes used in stereotactic radiosurgery, lateral electronic disequilibrium and steep dose gradients exist in a large portion of these fields, requiring the use of high-resolution measurement techniques. For small beams, the detector size approaches the dimensions of the beam and adversely affects measurement accuracy in regions where the gradient varies across the detector. When film is the detector, the scanning system is usually the resolution-limiting component. Radiographic films based upon silver halide (AgH) emulsions are widely used for relative dosimetry of external radiation treatment beams in the megavoltage energy range, because of their good spatial resolution and capability to provide integrated dosimetry over two dimensions. Film dosimetry, however, has drawbacks due to its steep energy dependence at low photon energies as well as film processor and densitometer artifacts. EBT radiochromic film, introduced in 2004 specifically for IMRT dosimetry, may be a detector of choice for the characterization of small radiosurgical beams, because of its near-tissue equivalence, radiation beam energy independence, high spatial resolution, and self developing properties. For radiation beam sizes greater than 10 rum, the film measurements were identical to those of the diode and ion chamber. For the smaller beam diameters of 7.5 and 5 rum, however, there were differences in the data measured with the different detectors, which are attributed to their different spatial resolution and non-water-equivalence. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1967 / 1974
页数:8
相关论文
共 50 条
  • [21] Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry
    Rebecca Moylan
    Trent Aland
    Tanya Kairn
    Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 331 - 337
  • [22] Ion beam dosimetry using Gafchromic EBT3 film
    Hassan, M. G.
    El-Saftawy, A. A.
    Soliman, B. A.
    Abdelrahman, M. M.
    Abdelmageed, K. E.
    Hassouba, M. A.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2024, 130 (06):
  • [23] Multichannel absolute film dosimetry for EBT3 GafChromic films
    Ventura, T.
    Lopes, M. C.
    Ferreira, B. C.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S169 - S169
  • [24] Comparison of the radio chromatic EBT film Dosimetry with EBT2 (Gafchromic) for IMRT Verification
    Schwedas, M.
    Howitz, S.
    Wiezorek, T.
    Wendt, T. G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 105 - 105
  • [25] Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance
    Fuss, Martina
    Sturtewagen, Eva
    De Wagter, Carlos
    Georg, Dietmar
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (14): : 4211 - 4225
  • [26] Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC® film
    Lynch, Bart D.
    Kozelka, Jakub
    Ranade, Manisha K.
    Li, Jonathan G.
    Simon, William E.
    Dempsey, James F.
    MEDICAL PHYSICS, 2006, 33 (12) : 4551 - 4556
  • [27] Evaluation of gafchromic EBT film for prostate IMRT verification
    Aziz, T.
    Budgell, G. J.
    Mackay, R. I.
    CLINICAL ONCOLOGY, 2007, 19 (03) : S24 - S24
  • [28] Evaluation of the magnitude of EBT Gafchromic film polarization effects
    M. J. Butson
    T. Cheung
    P. K. N. Yu
    Australasian Physics & Engineering Sciences in Medicine, 2009, 32 : 21 - 25
  • [29] Evaluation of the magnitude of EBT Gafchromic film polarization effects
    Butson, M. J.
    Cheung, T.
    Yu, P. K. N.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2009, 32 (01) : 21 - 25
  • [30] Gafchromic EBT film dosimetry outside a multi-leaf collimated beam
    Fiandra, C
    Ragona, R
    Ricardi, U
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S199 - S200