Evaluation of GAFCHROMIC® EBT film for CyberKnife® dosimetry

被引:111
|
作者
Wilcox, Ellen E. [1 ]
Daskalov, George M. [1 ]
机构
[1] St Francis Hosp & Med Ctr, Dept Radiat Oncol, Hartford, CT 06105 USA
关键词
EBT film dosimetry; stereotactic radiosurgery;
D O I
10.1118/1.2734384
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
External beam therapy (EBT) GAFCHROMIC (R) film is evaluated for dosimetry and characterization of the CyberKnife (R) radiation beams. Percentage depth doses, lateral beam profiles, and output factors are measured in solid water using EBT GAFCHROMIC (R) film (International Specialty Products, Wayne, NJ) for the 6 MV radiation beams of diameter 5 to 60 rum produced by the CyberKnife (R) (Accuray, Sunnyvale, CA). The data are compared to those measured with the PTW 60008 diode and the Wellhofer CC01 ion chamber in water. For the small radiation field sizes used in stereotactic radiosurgery, lateral electronic disequilibrium and steep dose gradients exist in a large portion of these fields, requiring the use of high-resolution measurement techniques. For small beams, the detector size approaches the dimensions of the beam and adversely affects measurement accuracy in regions where the gradient varies across the detector. When film is the detector, the scanning system is usually the resolution-limiting component. Radiographic films based upon silver halide (AgH) emulsions are widely used for relative dosimetry of external radiation treatment beams in the megavoltage energy range, because of their good spatial resolution and capability to provide integrated dosimetry over two dimensions. Film dosimetry, however, has drawbacks due to its steep energy dependence at low photon energies as well as film processor and densitometer artifacts. EBT radiochromic film, introduced in 2004 specifically for IMRT dosimetry, may be a detector of choice for the characterization of small radiosurgical beams, because of its near-tissue equivalence, radiation beam energy independence, high spatial resolution, and self developing properties. For radiation beam sizes greater than 10 rum, the film measurements were identical to those of the diode and ion chamber. For the smaller beam diameters of 7.5 and 5 rum, however, there were differences in the data measured with the different detectors, which are attributed to their different spatial resolution and non-water-equivalence. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1967 / 1974
页数:8
相关论文
共 50 条
  • [1] Gafchromic EBT film dosimetry in proton beams
    Zhao, Li
    Das, Indra J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (10): : N291 - N301
  • [2] Evaluation of the Gafchromic® EBT2 film for the dosimetry of radiosurgical beams
    Larraga-Gutierrez, Jose M.
    Garcia-Hernandez, Diana
    Garcia-Garduno, Olivia A.
    Galvan de la Cruz, Olga O.
    Ballesteros-Zebadua, Paola
    Esparza-Moreno, Karina P.
    MEDICAL PHYSICS, 2012, 39 (10) : 6111 - 6117
  • [3] Proton Beam Dosimetry Using Gafchromic EBT Film
    Zhao, Li
    Das, I.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [4] Scanning orientation effects on Gafchromic EBT film dosimetry
    Butson M.J.
    Cheung T.
    Yu P.K.N.
    Australasian Physical and Engineering Sciences in Medicine, 2006, 29 (03): : 281 - 284
  • [5] Verification of CyberKnife Dose Distributions with Gafchromic EBT2 Film
    Koksal, Canan
    Akbas, Ugur
    Kesen, Nazmiye Donmez
    Bilge, Hatice
    Kemikler, Gonul
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2018, 33 (04): : 147 - 153
  • [6] CORVUS IMRT film dosimetry using novel GafChromic EBT film
    Trichter, F
    Trichter, S
    MEDICAL PHYSICS, 2005, 32 (06) : 2167 - 2167
  • [7] Assessment of the Accuracy of Gafchromic® EBT Film Dosimetry in Inhomogeneous Media
    Jeong, H.
    Kum, O.
    Han, Y.
    Kim, C.
    Suh, T.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [8] Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance
    Aland, T.
    Kairn, T.
    Kenny, J.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (02) : 251 - 260
  • [9] Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance
    T. Aland
    T. Kairn
    J. Kenny
    Australasian Physical & Engineering Sciences in Medicine, 2011, 34 : 251 - 260
  • [10] Analysis of uncertainties in Gafchromic® EBT film dosimetry of photon beams
    Martisikova, Maria
    Ackermann, Benjamin
    Jaekel, Oliver
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (24): : 7013 - 7027