Quantifying the importance of high frequency components on the amplitude of physiological tremor

被引:20
|
作者
Carignan, Benoit [1 ]
Daneault, Jean-Francois [1 ]
Duval, Christian [1 ]
机构
[1] Univ Quebec, Dept Kinanthropol, Montreal, PQ H3C 3P8, Canada
关键词
Tremor analysis; Laser; Amplitude; Velocity; Acceleration; VENTROLATERAL THALAMOTOMY; VISUAL FEEDBACK; DOMAIN CHARACTERISTICS; ALTERNATING MOVEMENTS; CENTRAL MECHANISMS; FINGER TREMOR; 40; HZ; IMPACT; SYNCHRONIZATION; OSCILLATIONS;
D O I
10.1007/s00221-009-2132-7
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The objective of this study was to determine the importance of every frequency component on total physiological tremor (PT) amplitude. We suspect that since high frequencies of PT are of lower amplitude in displacement, removing them will have little to no impact on PT amplitude. PT of the index finger was measured with a laser displacement sensor while the finger was held horizontally. Amplitude of tremor was calculated in displacement, velocity and acceleration. PT amplitude was also calculated within five frequency bands. Although displacement amplitude of oscillations within the 7.5-12.5 and 16.5-30 Hz frequency bands represent 24 and 10% of total PT oscillation amplitude, respectively, their removal reduced PT amplitude by less than 3%. Conversely, the removal of the oscillations within 1-3.5 Hz band from the PT signal reduced the amplitude of the original PT signal by 56% in displacement. This suggests that when a task to be studied involves the measurement of a reduction in tremor, focus should be on the oscillations in the 1-3.5 Hz band.
引用
收藏
页码:299 / 306
页数:8
相关论文
共 50 条
  • [41] TUNING THE POWER SPECTRUM OF PHYSIOLOGICAL FINGER TREMOR FREQUENCY WITH FLICKERING LIGHT
    ISOKAWAAKESSON, M
    KOMISARUK, BR
    JOURNAL OF NEUROSCIENCE RESEARCH, 1985, 14 (03) : 373 - 380
  • [42] Methods of time and frequency domain examination of physiological tremor in the human jaw
    Sowman, PF
    Türker, KS
    HUMAN MOVEMENT SCIENCE, 2005, 24 (5-6) : 657 - 666
  • [43] Possible modulation of the amplitude and frequency of resting parkinsonian tremor by touching the trapezius muscle
    Hasegawa, Takafumi
    Ishiyama, Shun
    Nakamura, Takaaki
    CLINICAL CASE REPORTS, 2020, 8 (08): : 1594 - 1594
  • [44] Shoulder, elbow and wrist components of physiologic tremor amplitude as measured using a laser penlight
    Davis, BJ
    O'Connell, J
    EUROPEAN NEUROLOGY, 2000, 43 (03) : 152 - 154
  • [45] Tremor amplitude and tremor frequency variability in Parkinson's disease is dependent on activity and synchronisation of central oscillators in basal ganglia
    Bartolic, Andrej
    Pirtosek, Zvezdan
    Rozman, Janez
    Ribaric, Samo
    MEDICAL HYPOTHESES, 2010, 74 (02) : 362 - 365
  • [46] The spectral analysis of the variability of frequency and amplitude characteristics of tremor in patients with essential tremor and tremulous form of Parkinson's disease
    Golubev, V. L.
    Magomedova, R. K.
    ZHURNAL NEVROLOGII I PSIKHIATRII IMENI S S KORSAKOVA, 2006, 106 (01) : 43 - 48
  • [47] Evidence for tidal triggering of high-amplitude rapid tremor reversals and tremor streaks in northern Cascadia
    Thomas, Trevor W.
    Vidale, John E.
    Houston, Heidi
    Creager, Kenneth C.
    Sweet, Justin R.
    Ghosh, Abhijit
    GEOPHYSICAL RESEARCH LETTERS, 2013, 40 (16) : 4254 - 4259
  • [48] FREQUENCY, SEVERITY, AND PHYSIOLOGICAL IMPORTANCE OF CAROTID SIPHON LESIONS
    KEAGY, BA
    POOLE, MA
    BURNHAM, SJ
    JOHNSON, G
    JOURNAL OF VASCULAR SURGERY, 1986, 3 (03) : 511 - 515
  • [49] THE EFFECT OF THYROID-FUNCTION ON THE AMPLITUDE AND FREQUENCY-CHARACTERISTICS OF POSTURAL FINGER TREMOR
    HALONEN, JP
    HAATAJA, M
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1982, 54 (04): : P45 - P45
  • [50] AMPLITUDE CYCLES OF TREMOR, MUSCLE OSCILLATION AND EEG BY MEANS OF RUNNING FREQUENCY-ANALYSIS
    KEIDEL, M
    KEIDEL, WD
    TIRSCH, WS
    POPPL, SJ
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1988, 69 (01): : P14 - P14