Quantifying the importance of high frequency components on the amplitude of physiological tremor

被引:20
|
作者
Carignan, Benoit [1 ]
Daneault, Jean-Francois [1 ]
Duval, Christian [1 ]
机构
[1] Univ Quebec, Dept Kinanthropol, Montreal, PQ H3C 3P8, Canada
关键词
Tremor analysis; Laser; Amplitude; Velocity; Acceleration; VENTROLATERAL THALAMOTOMY; VISUAL FEEDBACK; DOMAIN CHARACTERISTICS; ALTERNATING MOVEMENTS; CENTRAL MECHANISMS; FINGER TREMOR; 40; HZ; IMPACT; SYNCHRONIZATION; OSCILLATIONS;
D O I
10.1007/s00221-009-2132-7
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The objective of this study was to determine the importance of every frequency component on total physiological tremor (PT) amplitude. We suspect that since high frequencies of PT are of lower amplitude in displacement, removing them will have little to no impact on PT amplitude. PT of the index finger was measured with a laser displacement sensor while the finger was held horizontally. Amplitude of tremor was calculated in displacement, velocity and acceleration. PT amplitude was also calculated within five frequency bands. Although displacement amplitude of oscillations within the 7.5-12.5 and 16.5-30 Hz frequency bands represent 24 and 10% of total PT oscillation amplitude, respectively, their removal reduced PT amplitude by less than 3%. Conversely, the removal of the oscillations within 1-3.5 Hz band from the PT signal reduced the amplitude of the original PT signal by 56% in displacement. This suggests that when a task to be studied involves the measurement of a reduction in tremor, focus should be on the oscillations in the 1-3.5 Hz band.
引用
收藏
页码:299 / 306
页数:8
相关论文
共 50 条
  • [21] FREQUENCY AND DISPLACEMENT AMPLITUDE RELATIONS FOR NORMAL HAND TREMOR
    STILES, RN
    JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (01) : 44 - 54
  • [22] Quantification of sensory trick impact on tremor amplitude and frequency in 60 patients with head tremor
    Masuhr, F
    Wissel, J
    Müller, J
    Scholz, U
    Poewe, W
    MOVEMENT DISORDERS, 2000, 15 (05) : 960 - 964
  • [23] Shoulder posture differentially modifies the amplitude of essential, parkinsonian and physiological tremor
    Popa, T.
    Gelli, F.
    DelSanto, F.
    Biasella, A.
    Dominici, F.
    Rossi, A.
    Mazzocchio, R.
    MOVEMENT DISORDERS, 2006, 21 : S697 - S697
  • [24] EXERCISE-INDUCED AMPLITUDE MODIFICATION OF PHYSIOLOGICAL ACTION TREMOR OF THE ANKLE
    IAIZZO, PA
    POZOS, RS
    JOURNAL OF APPLIED PHYSIOLOGY, 1982, 53 (05) : 1164 - 1170
  • [25] Targeting the fundamentals for tremors: the frequency and amplitude coding in essential tremor
    Pan, Ming-Kai
    JOURNAL OF BIOMEDICAL SCIENCE, 2025, 32 (01)
  • [26] Components of physiological tremor in static and dynamic muscle contractions.
    Christakos, CN
    Erimaki, S
    EUROPEAN JOURNAL OF NEUROSCIENCE, 2000, 12 : 149 - 149
  • [27] Automated tremor amplitude and frequency determination from power spectra
    Bartolic, Andrej
    Santic, Mihovil
    Ribaric, Samo
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2009, 94 (01) : 77 - 87
  • [28] Physiological and harmonic components in neural and muscular coherence in Parkinsonian tremor
    Wang, Shouyan
    Aziz, Tipu Z.
    Stein, John F.
    Bain, Peter G.
    Liu, Xuguang
    CLINICAL NEUROPHYSIOLOGY, 2006, 117 (07) : 1487 - 1498
  • [29] Publisher Correction: Using high-amplitude and focused transcranial alternating current stimulation to entrain physiological tremor
    Ahmad Khatoun
    Jolien Breukers
    Sara Op de Beeck
    Ioana Gabriela Nica
    Jean-Marie Aerts
    Laura Seynaeve
    Tom Haeck
    Boateng Asamoah
    Myles Mc Laughlin
    Scientific Reports, 8
  • [30] PHYSIOLOGICAL IMPORTANCE OF UNSAPONIFIABLE COMPONENTS IN DIETARY FATS
    ELMADFA, I