Simple analyzer for continuous monitoring of sulfur dioxide in gas streams

被引:10
|
作者
Marzouk, Sayed A. M. [1 ]
Al-Marzouqi, Mohamed H. [2 ]
Baomran, Samira M. S. M. [1 ]
机构
[1] UAE Univ, Dept Chem, Al Ain, U Arab Emirates
[2] UAE Univ, Dept Chem & Petr Engn, Al Ain, U Arab Emirates
关键词
Gas analyzer; Sulfur dioxide determination; Hollow fiber membrane contactors; pH detector; Conductivity detector; FLOW-INJECTION ANALYSIS; GLASSY-CARBON ELECTRODE; CONDUCTOMETRIC DETECTOR; AMPEROMETRIC SENSOR; SODIUM DITHIONITE; SULFITE; SO2; WINE; AIR; CHEMILUMINESCENCE;
D O I
10.1016/j.microc.2009.12.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction, optimization and use of simple and inexpensive gas analyzer for real time measurement of sulfur dioxide in gas streams are described The analyzer consisted of three main components (i) a custom fabricated hollow fiber membrane (HFM) gas contactor, (ii) carrier solution which absorbs SO(2) molecules from the gas stream in the HFM gas contactor and (in) a flow-through detector placed downstream which continuously measures the changes occurred to the carrier solution upon absorption of SO(2) molecules The significant acidic properties of the produced sulfurous acid suggested pH and conductivity detectors to monitor the decrease in pH or the increase in the conductivity which constituted the basis for quantification of SO(2) in the gas line Aqueous potassium oxalate (10(-1) mol/L) and hydrogen peroxide (10(-3) mol/L) were used as carrier solutions in combination with pH and conductivity detectors, respectively The analyzer equipped with pH detector provided linear potentiometric response to SO(2) concentration up to 1000 ppm with Nernstian slop of 61 mV/log[SO(2)] Excellent SO(2) recoveries (97-108%) were obtained in the presence of several folds of potentially interfering acidic gases, i e CO(2) and H(2)S The conductivity detector provided linear response up to 2500 ppm. Under optimized conditions, both detectors offered several favorable performance characteristics such as (i) fast response and recovery times, (ii) excellent signal stability and reproducibility (RSD = 0.5%), (iii) intrinsic high selectivity to most common neutral gases, e g, CH(4), N(2), O(2), CO, etc The suggested analyzer was applied successfully in monitoring the removal of SO(2) from SO(2)-N(2) gas mixtures with hollow fiber membrane contactor using distilled water or aqueous sodium hydroxide as stripping solvents. (C) 2009 Elsevier B V All rights reserved
引用
收藏
页码:207 / 212
页数:6
相关论文
共 50 条
  • [41] Research in Automobile Exhaust Gas of Sulfur Dioxide and Nitrogen Dioxide Monitoring WSN and Optimization Coverage Algorithm
    Zhou Yushan
    Zhang Yiwei
    Chu Linlin
    Liu Congning
    Shi Yunbo
    2015 FIFTH INTERNATIONAL CONFERENCE ON INSTRUMENTATION AND MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC), 2015, : 1202 - 1205
  • [42] A stationary gas analyzer of nitric and sulfur oxides
    A. A. Azbukin
    M. A. Buldakov
    B. V. Korolev
    V. A. Korol’kov
    I. I. Matrosov
    A. A. Tikhomirov
    Instruments and Experimental Techniques, 2006, 49 : 839 - 843
  • [43] A stationary gas analyzer of nitric and sulfur oxides
    Azbukin, A. A.
    Buldakov, M. A.
    Korolev, B. V.
    Korol'kov, V. A.
    Matrosov, I. I.
    Tikhomirov, A. A.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2006, 49 (06) : 839 - 843
  • [44] Gas analyzer for continuous monitoring of trace level methanethiol by microchannel collection and fluorescence detection
    Toda, Kei
    Kuwahara, Haruka
    Kajiwara, Hidetaka
    Hirota, Kazutoshi
    Ohira, Shin-Ichi
    ANALYTICA CHIMICA ACTA, 2014, 841 : 1 - 9
  • [45] Studies on gas flow injection and continuous flow analysis system - Electrochemical determination of sulfur dioxide gas
    Liu, SJ
    Shen, HX
    Feng, JX
    ACTA CHIMICA SINICA, 1996, 54 (08) : 813 - 818
  • [46] PORTABLE CONTINUOUS CHROMATOGRAPHIC COULOMETRIC SULFUR EMISSION ANALYZER
    ROBERTUS, RJ
    SCHAER, MJ
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1973, 7 (09) : 849 - 852
  • [47] Sulfur hexafluoride gas tracer studies in streams
    Hibbs, DE
    Parkhill, KL
    Gulliver, JS
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1998, 124 (08): : 752 - 760
  • [48] MICROPROCESSOR CONTROLLED ANALYZER FOR GAS MONITORING
    DAETZ, M
    TREPTOW, T
    WIEDERMANN, B
    TECHNISCHES MESSEN, 1987, 54 (11): : 439 - 441
  • [49] Optimization of a monitoring network for sulfur dioxide
    Boer, EPJ
    Dekkers, ALM
    Stein, A
    JOURNAL OF ENVIRONMENTAL QUALITY, 2002, 31 (01) : 121 - 128
  • [50] SULFUR FROM SMELTER GAS BY REDUCTION OF SULFUR DIOXIDE
    YODIS, AW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1969, (SEP): : FE24 - &