Simple analyzer for continuous monitoring of sulfur dioxide in gas streams

被引:10
|
作者
Marzouk, Sayed A. M. [1 ]
Al-Marzouqi, Mohamed H. [2 ]
Baomran, Samira M. S. M. [1 ]
机构
[1] UAE Univ, Dept Chem, Al Ain, U Arab Emirates
[2] UAE Univ, Dept Chem & Petr Engn, Al Ain, U Arab Emirates
关键词
Gas analyzer; Sulfur dioxide determination; Hollow fiber membrane contactors; pH detector; Conductivity detector; FLOW-INJECTION ANALYSIS; GLASSY-CARBON ELECTRODE; CONDUCTOMETRIC DETECTOR; AMPEROMETRIC SENSOR; SODIUM DITHIONITE; SULFITE; SO2; WINE; AIR; CHEMILUMINESCENCE;
D O I
10.1016/j.microc.2009.12.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction, optimization and use of simple and inexpensive gas analyzer for real time measurement of sulfur dioxide in gas streams are described The analyzer consisted of three main components (i) a custom fabricated hollow fiber membrane (HFM) gas contactor, (ii) carrier solution which absorbs SO(2) molecules from the gas stream in the HFM gas contactor and (in) a flow-through detector placed downstream which continuously measures the changes occurred to the carrier solution upon absorption of SO(2) molecules The significant acidic properties of the produced sulfurous acid suggested pH and conductivity detectors to monitor the decrease in pH or the increase in the conductivity which constituted the basis for quantification of SO(2) in the gas line Aqueous potassium oxalate (10(-1) mol/L) and hydrogen peroxide (10(-3) mol/L) were used as carrier solutions in combination with pH and conductivity detectors, respectively The analyzer equipped with pH detector provided linear potentiometric response to SO(2) concentration up to 1000 ppm with Nernstian slop of 61 mV/log[SO(2)] Excellent SO(2) recoveries (97-108%) were obtained in the presence of several folds of potentially interfering acidic gases, i e CO(2) and H(2)S The conductivity detector provided linear response up to 2500 ppm. Under optimized conditions, both detectors offered several favorable performance characteristics such as (i) fast response and recovery times, (ii) excellent signal stability and reproducibility (RSD = 0.5%), (iii) intrinsic high selectivity to most common neutral gases, e g, CH(4), N(2), O(2), CO, etc The suggested analyzer was applied successfully in monitoring the removal of SO(2) from SO(2)-N(2) gas mixtures with hollow fiber membrane contactor using distilled water or aqueous sodium hydroxide as stripping solvents. (C) 2009 Elsevier B V All rights reserved
引用
收藏
页码:207 / 212
页数:6
相关论文
共 50 条
  • [31] Monitoring of atmospheric sulfur dioxide
    Dodin, EI
    INDUSTRIAL LABORATORY, 1996, 62 (11): : 688 - 689
  • [32] MONITORING SULFUR-DIOXIDE
    DILLON, JA
    INSTRUMENTS & CONTROL SYSTEMS, 1972, 45 (04): : 23 - +
  • [33] Monitoring of Atmospheric Sulfur Dioxide
    Dodin, E. I.
    Industrial Laboratory (USSR) (English translation of Zavodskaya Laboratoriya), 1996, 62 (11):
  • [34] Simultaneous removal of nitrogen oxide/nitrogen dioxide/sulfur dioxide from gas streams by combined plasma scrubbing technology
    Chang, MB
    Lee, HM
    Wu, FL
    Lai, CR
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2004, 54 (08): : 941 - 949
  • [35] DETERMINATION OF CARBON DIOXIDE IN GAS STREAMS
    TOREN, PE
    HEINRICH, BJ
    ANALYTICAL CHEMISTRY, 1957, 29 (12) : 1854 - 1856
  • [36] DESIGN AND CONSTRUCTION OF A SIMPLE, CONTINUOUS-FLOW SULFUR-DIOXIDE EXPOSURE CHAMBER
    LEETHAM, JW
    FERGUSON, W
    DODD, JL
    LAUENROTH, WK
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1982, 32 (02): : 181 - 182
  • [37] Load analyzer provides continuous monitoring
    Anon
    Modern Plastics, 2001, 78 (06):
  • [38] SIMPLE QUADRUPOLE RESIDUAL GAS ANALYZER
    RETTINGHAUS, G
    HUBER, WK
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1971, 8 (01): : 272 - +
  • [39] SIMPLE SULFUR-DIOXIDE METER
    WISE, JCM
    DAVIES, A
    MEDICAL & BIOLOGICAL ENGINEERING, 1976, 14 (05): : 545 - 547
  • [40] A CONTINUOUS GAS TITRATION ANALYZER FOR FLUORINE
    WEBER, CW
    ANALYTICAL CHEMISTRY, 1960, 32 (03) : 387 - 391