The construction, optimization and use of simple and inexpensive gas analyzer for real time measurement of sulfur dioxide in gas streams are described The analyzer consisted of three main components (i) a custom fabricated hollow fiber membrane (HFM) gas contactor, (ii) carrier solution which absorbs SO(2) molecules from the gas stream in the HFM gas contactor and (in) a flow-through detector placed downstream which continuously measures the changes occurred to the carrier solution upon absorption of SO(2) molecules The significant acidic properties of the produced sulfurous acid suggested pH and conductivity detectors to monitor the decrease in pH or the increase in the conductivity which constituted the basis for quantification of SO(2) in the gas line Aqueous potassium oxalate (10(-1) mol/L) and hydrogen peroxide (10(-3) mol/L) were used as carrier solutions in combination with pH and conductivity detectors, respectively The analyzer equipped with pH detector provided linear potentiometric response to SO(2) concentration up to 1000 ppm with Nernstian slop of 61 mV/log[SO(2)] Excellent SO(2) recoveries (97-108%) were obtained in the presence of several folds of potentially interfering acidic gases, i e CO(2) and H(2)S The conductivity detector provided linear response up to 2500 ppm. Under optimized conditions, both detectors offered several favorable performance characteristics such as (i) fast response and recovery times, (ii) excellent signal stability and reproducibility (RSD = 0.5%), (iii) intrinsic high selectivity to most common neutral gases, e g, CH(4), N(2), O(2), CO, etc The suggested analyzer was applied successfully in monitoring the removal of SO(2) from SO(2)-N(2) gas mixtures with hollow fiber membrane contactor using distilled water or aqueous sodium hydroxide as stripping solvents. (C) 2009 Elsevier B V All rights reserved
引用
收藏
页码:207 / 212
页数:6
相关论文
共 50 条
  • [1] Gas analyzer for continuous monitoring of carbon dioxide in gas streams
    Marzouk, Sayed A. M.
    Al-Marzouqi, Mohamed H.
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (01) : 398 - 404
  • [2] Portable dual-channel gas analyzer for continuous monitoring of carbon dioxide in gas streams
    Bufaroosha, Muna S.
    Alnaqbi, Mohamed A. R. A.
    Al-Marzouqi, Mohamed H.
    Marzouk, Sayed A. M.
    MICROCHEMICAL JOURNAL, 2013, 110 : 185 - 191
  • [3] AUTOMATIC RADIOISOTOPIC ANALYZER FOR CONTINUOUS CONTROL OF SULFUR CONTENT IN GAS STREAMS
    KHALYAPI.SA
    MIRONOV, AE
    ZAVODSKAYA LABORATORIYA, 1972, (03): : 373 - &
  • [4] CONTINUOUS ANALYZER OF SULFUR-DIOXIDE
    VECERA, Z
    MIKUSKA, P
    JANAK, J
    OPEKAR, F
    TROJANEK, A
    CHEMICKE LISTY, 1990, 84 (03): : 316 - 320
  • [5] Portable analyzer for continuous monitoring of sulfur dioxide in gas stream based on amperometric detection and stabilized gravity-driven flow
    Alnaqbi, Mohamed A. R. A.
    Bufaroosha, Muna S.
    Al-Marzouqi, Mohamed H.
    Marzouk, Sayed A. M.
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 225 : 24 - 33
  • [6] Determination of carbon dioxide in continuous gas streams
    Martin, WM
    Green, JR
    INDUSTRIAL AND ENGINEERING CHEMISTRY-ANALYTICAL EDITION, 1933, 5 : 114 - 118
  • [7] Continuous monitoring of sulfur dioxide with a gas permeation denuder-based system
    Guo, ZX
    Zhang, XX
    Gao, Y
    Li, YZ
    Chang, WB
    Ci, YX
    MICROCHIMICA ACTA, 2003, 141 (3-4) : 183 - 189
  • [8] Continuous Monitoring of Sulfur Dioxide with a Gas Permeation Denuder-Based System
    Zhong-Xian Guo
    Xin-Xiang Zhang
    Yi Gao
    Yuan-Zong Li
    Wen-Bao Chang
    Yun-Xiang Ci
    Microchimica Acta, 2003, 141 : 183 - 189
  • [9] INFRARED ANALYZER FOR MONITORING WATER CONTENT - LIQUID SULFUR DIOXIDE - GAS OIL EXTRACTION UNIT
    KARASEK, FW
    MILLER, EC
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1954, 46 (07): : 1374 - 1376
  • [10] Analyzer for continuous monitoring of H2S in gas streams based on a novel thermometric detection
    Marzouk, Sayed A. M.
    Al-Marzouqi, Mohamed H.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 162 (01) : 377 - 383