New equations for Nusselt number and friction factor of the annulus side of the conically coiled tubes in tube heat exchangers

被引:22
|
作者
Ali, Mohamed [1 ]
Rad, Milad Mansouri [2 ]
Nuhait, Abdullah [1 ]
Almuzaiqer, Redhwan [1 ]
Alimoradi, Ashkan [3 ]
Tlili, Iskander [4 ,5 ]
机构
[1] King Saud Univ, Coll Engn, Mech Engn Dept, POB 800, Riyadh 11421, Saudi Arabia
[2] Amirkabir Univ Technol, Tehran Polytech, Dept Energy Engn & Phys, Tehran, Iran
[3] Kermanshah Univ Med Sci, Sch Paramed, Kermanshah, Iran
[4] Ton Duc Thang Univ, Dept Management Sci & Technol Dev, Ho Chi Minh City, Vietnam
[5] Ton Duc Thang Univ, Fac Appl Sci, Ho Chi Minh City, Vietnam
关键词
Heat transfer; Nusselt number; Friction factor; Conically coiled tube; Turbulent flow; Numerical modeling; PRESSURE-DROP CHARACTERISTICS; ENTROPY GENERATION; HELICAL-COILS; FLOW CHARACTERISTICS; THERMAL PERFORMANCE; NATURAL-CONVECTION; TIO2/WATER NANOFLUIDS; TRANSFER COEFFICIENTS; SHELL; CONDENSATION;
D O I
10.1016/j.applthermaleng.2019.114545
中图分类号
O414.1 [热力学];
学科分类号
摘要
Three dimensional simulation of heat transfer (turbulent/laminar) and fluid flow of water through the annulus side of conically tube heat exchangers is presented in this study. This study shows an accurate and clear results which were not available before. Realizable K-epsilon model is chosen for perusing the turbulence influences. The influence of operational and geometrical characteristics on the Friction factor and the Nusselt number is obtained. The results show if the cone angle increases from 0 degrees to 90 degrees the Friction factor and the Nusselt number increase by 15.51% and 37.17%, respectively. Furthermore, it is concluded that if the dimensionless ratio of the outer tube diameter to the inner one increases by 50% the Nusselt number increases by 39.11% while the friction factor decreases by 23.29%. The outcomes of this study proposed two new correlations (that cannot be found in the previous studies) to estimate the friction factor and the Nusselt number of the annulus side of these heat exchangers. These proposed equations are necessary and important for engineering applications involving designs of these heat exchangers. Furthermore, the current results are validated using the experimental data available in the literature. This validation shows an average error of only 9.87% in calculating Nusselt numbers, which is more accurate than any other predictive equations available in the literature.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Impacts of nanofluid flow on skin friction factor and Nusselt number in curved tubes with constant mass flow
    Akbarinia, A.
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2008, 29 (01) : 229 - 241
  • [32] Study on shell side heat transport enhancement of double tube heat exchangers by twisted oval tubes
    Li, Xiuzhen
    Wang, Lin
    Feng, Rong
    Wang, Zhanwei
    Liu, Shijie
    Zhu, Dongsheng
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 124
  • [33] Analysis of the thermal and hydraulic performance of the sector-by-sector helically coiled tube heat exchangers as a new type of heat exchangers
    Abu-Hamdeh, Nidal H.
    Bantan, Rashad A. R.
    Tlili, Iskander
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2020, 150
  • [34] Air-side heat transfer and friction correlations for plain fin-and-tube heat exchangers with staggered tube arrangements
    Kim, N.H.
    Youn, B.
    Webb, R.L.
    Journal of Heat Transfer, 1999, 121 (03): : 662 - 667
  • [35] Heat transfer and friction factor analysis of MWCNT nanofluids in double helically coiled tube heat exchanger
    P. C. Mukesh Kumar
    M. Chandrasekar
    Journal of Thermal Analysis and Calorimetry, 2021, 144 : 219 - 231
  • [36] Heat transfer and friction factor analysis of MWCNT nanofluids in double helically coiled tube heat exchanger
    Mukesh Kumar, P. C.
    Chandrasekar, M.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 144 (01) : 219 - 231
  • [37] Fin Pattern Effects on Air-Side Heat Transfer and Friction Characteristics of Fin-and-Tube Heat Exchangers with Large Number of Large-Diameter Tube Rows
    Tang, Ling-Hong
    Min, Zeng
    Xie, Gong-Nan
    Wang, Qiu-Wang
    HEAT TRANSFER ENGINEERING, 2009, 30 (03) : 171 - 180
  • [38] A heat transfer and friction factor correlation for low air-side Reynolds number applications of compact heat exchangers (1535-RP)
    Shinde, Pradeep
    Lin, Cheng-Xian
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (01) : 192 - 210
  • [39] ANFIS for analysis friction factor and Nusselt number of pulsating nanofluids flow in the fluted tube under magnetic field
    Naphon, P.
    Arisariyawong, T.
    Wiriyasart, S.
    Srichat, A.
    CASE STUDIES IN THERMAL ENGINEERING, 2020, 18
  • [40] CFD analyses and correlation of pressure losses on the shell-side of concentric, helically-coiled tubes heat exchangers
    Haskins, Denise A.
    El-Genk, Mohamed S.
    NUCLEAR ENGINEERING AND DESIGN, 2016, 305 : 531 - 546