Cr/Sc multilayers for the soft-x-ray range

被引:65
|
作者
Schafers, F
Mertins, HC
Schmolla, F
Packe, I
Salashchenko, NN
Shamov, EA
机构
[1] BESSY MBH, D-14195 Berlin, Germany
[2] Russian Acad Sci, Inst Phys Microstruct, Nizhnii Novgorod 603600, Russia
来源
APPLIED OPTICS | 1998年 / 37卷 / 04期
关键词
D O I
10.1364/AO.37.000719
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have systematically investigated ultrathin Cr/Sc multilayers (nanolayers), using tunable soft-x-ray synchrotron radiation. The multilayers were optimized for use either in normal incidence or at 45 degrees at photon energies around the 2p-absorption edges of Sc (399 eV) and Cr (574 eV), respectively. They were sputter deposited on Si wafers or on thin Si3N4-membrane support structures for use in reflection and in transmission, respectively, as polarizing and phase-retarding elements in a polarimeter. The performance theoretically expected with respect to reflection/transmission and energy resolution has been confirmed experimentally: A value of 7% for the normal-incidence peak reflectance at 395 eV was measured as well as a pronounced minimum in transmission for certain incidence angles and energies below the respective absorption edges, indicating significant phase-shifting effects. (C) 1998 Optical Society of America.
引用
收藏
页码:719 / 728
页数:10
相关论文
共 50 条
  • [41] Short-period X-ray multilayers based on Cr/Sc, W/Sc
    Salashchenko, NN
    Fraerman, AA
    Mitenin, SV
    Prokhorov, KA
    Shamov, EA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 405 (2-3): : 292 - 296
  • [42] SOFT-X-RAY MICROSCOPY
    BAEZ, AV
    PHYSICS TODAY, 1986, 39 (05) : 11 - &
  • [43] SOFT-X-RAY LASERS
    MATTHEWS, DL
    ROSEN, MD
    SCIENTIFIC AMERICAN, 1988, 259 (06) : 86 - 91
  • [44] SOFT-X-RAY CALORIMETER
    PAK, VS
    CHISTYAKOV, SA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1991, 34 (04) : 958 - 961
  • [45] SOFT-X-RAY COLLIMATOR
    WRISTON, RS
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (12): : 1576 - 1576
  • [46] SOFT-X-RAY COLLIMATION
    ANANIN, OB
    BYKOVSKII, YA
    ZVERKOV, AK
    FRONDZEI, IY
    KVANTOVAYA ELEKTRONIKA, 1987, 14 (03): : 617 - 618
  • [47] SOFT-X-RAY THERAPY
    GOLDSCHMIDT, H
    HAUTARZT, 1978, 29 (11): : 612 - 612
  • [48] SOFT-X-RAY MICROSCOPES
    KIRZ, J
    RARBACK, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (01): : 1 - 13
  • [49] SOFT-X-RAY SPECTROSCOPY
    URCH, DS
    JOURNAL DE PHYSIQUE III, 1994, 4 (09): : 1613 - 1623
  • [50] SOFT-X-RAY MICROSCOPY
    KIRZ, J
    SAYRE, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 695 - 697