Comparison of Tissue Doppler Velocities Obtained by Different Types of Echocardiography Systems: Are They Compatible?

被引:20
|
作者
Denes, Monika [1 ]
Farkas, Katalin [2 ]
Erdei, Tamas [1 ]
Lengyel, Maria [1 ]
机构
[1] Gottsegen Gyorgy Hungarian Inst Cardiol, H-1096 Budapest, Hungary
[2] Szent Imre Teaching Hosp, Budapest, Hungary
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2010年 / 27卷 / 03期
关键词
tissue Doppler imaging; diastolic function; systolic function; left ventricular filling pressures; VENTRICULAR DIASTOLIC FUNCTION; HEART-FAILURE; PROGNOSTIC VALUE; IMPACT;
D O I
10.1111/j.1540-8175.2009.01018.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Both systolic and diastolic tissue Doppler (TD) velocities have an important diagnostic and prognostic role in cardiology. We aimed to compare TD velocities between two different echocardiography systems. Patients: Thirty-one consecutive patients (mean age: 65.2 +/- 17.5 years; 12 males) were enrolled. Methods: Systolic (Sa), early (Ea), and late (Aa) diastolic velocities were measured by TD at the lateral mitral annulus by a Sonos 2000 (Hewlett-Packard, Andover, MA, USA) and a Philips iE33 system. The E/Ea ratio was calculated. Results: Ea, Aa, and Sa velocities were higher when measured by the Sonos system (Ea: 13.2 +/- 4.1 cm/s vs. 8.3 +/- 3.6 cm/s; Aa: 14.8 +/- 3.8 cm/s vs. 9.3 +/- 2.3 cm/s; Sa: 15.2 +/- 3.6 cm/s vs. 8.4 +/- 2.0 cm/s; P < 0.0001 all). A significant correlation was found in Ea and in Ea/Aa (r = 0.84 and r = 0.85 resp; P < 0.0001 for both), and a weaker in Aa (r = 0.43; P = 0.02) between the machines. The Bland-Altman analysis showed broad limits of agreement between the measurements for Ea, Aa, and Sa (mean difference: 4.95 cm/s; 5.52 cm/s; 6.73 cm/s, respectively; limits: 0.64-9.25 cm/s; -1.39-12.39 cm/s; -0.37-13.83 cm/s, respectively). An E/Ea ratio > 5.6 by the Sonos system showed 75% sensitivity and 79% specificity for elevated left ventricular filling pressure, defined as E/Ea > 10 by the reference Philips system. Conclusions: Although diastolic TD velocities had excellent correlations between the two machines, there was a systematic overestimation by the Sonos system. Since the limits of agreement do not allow replacing the measurements, we suggest using the same echocardiographic equipment at patient follow-up. (Echocardiography 2010;27:230-235).
引用
收藏
页码:230 / 235
页数:6
相关论文
共 50 条
  • [41] Comparison between parameters of diastolic function derived from conventional Doppler echocardiography and from Doppler tissue imaging
    Selton-Suty, C
    Mock, L
    Piquemal, R
    Nippert, M
    Vançon, AC
    Juillière, Y
    EUROPEAN HEART JOURNAL, 2002, 23 : 676 - 676
  • [42] Comparison of porous starches obtained from different enzyme types and levels
    Benavent-Gil, Yaiza
    Rosell, Cristina M.
    CARBOHYDRATE POLYMERS, 2017, 157 : 533 - 540
  • [43] Myocardial tissue doppler velocities and functional properties of erythrocytes in different remodeling patterns of left ventricle
    Mikhaliev, K.
    Kolomoiets, M.
    Chursina, T.
    Tkach, I
    Kaushanska, O.
    Kvasnytska
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2010, 15 : 25 - 25
  • [44] Tracking vs. tagging - tissue Doppler echocardiography in comparison with magnetic resonance imaging
    Borges, A
    Kivelitz, D
    Reibis, RK
    Walde, T
    Baumann, G
    EUROPEAN HEART JOURNAL, 2001, 22 : 708 - 708
  • [45] Quantitative tissue Doppler echocardiography in comparison with M-mode measurement in healthy subjects
    Bartel, T
    Muller, S
    Schurger, D
    Gassmann, B
    Ruttermann, V
    Erbel, R
    ZEITSCHRIFT FUR KARDIOLOGIE, 1997, 86 (02): : 131 - 137
  • [46] A comparison of tissue Doppler imaging and velocities of transmitral flow in children with elevated left ventricular preload
    Harada, K
    Tamura, M
    Yasuoka, K
    Toyono, M
    CARDIOLOGY IN THE YOUNG, 2001, 11 (03) : 261 - 268
  • [47] A COMPARISON OF PRECIPITATION VALUES OBTAINED BY DIFFERENT MEASURING SYSTEMS
    GUNTHER, R
    ZEITSCHRIFT FUR METEOROLOGIE, 1986, 36 (03): : 210 - 213
  • [48] Comparison of myocardial velocities by colour Doppler tissue imaging in normal subjects and in dilated cardiomyopathy.
    Derumeaux, G
    Cochonneau, O
    Douillet, R
    Cribier, A
    Letac, B
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1997, 90 (06): : 773 - 778
  • [49] Assessment of left atrial appendage wall velocities by transesophageal tissue Doppler echocardiography: A clinical study in patients with sinus rhythm
    Trambaiolo, P
    Salustri, A
    Tanga, M
    Tonti, G
    Fedele, F
    Palamara, A
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (05) : 425 - 432
  • [50] Quantitative tissue Doppler echocardiography: Physiological nonuniformity of left ventricular transmural myocardial wall-motion velocities and gradients
    Nixdorff, U
    Mohr-Kahaly, S
    Kremer, M
    Rippin, G
    Meyer, J
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1997, 14 (06): : 545 - 552