Comparison of Tissue Doppler Velocities Obtained by Different Types of Echocardiography Systems: Are They Compatible?

被引:20
|
作者
Denes, Monika [1 ]
Farkas, Katalin [2 ]
Erdei, Tamas [1 ]
Lengyel, Maria [1 ]
机构
[1] Gottsegen Gyorgy Hungarian Inst Cardiol, H-1096 Budapest, Hungary
[2] Szent Imre Teaching Hosp, Budapest, Hungary
关键词
tissue Doppler imaging; diastolic function; systolic function; left ventricular filling pressures; VENTRICULAR DIASTOLIC FUNCTION; HEART-FAILURE; PROGNOSTIC VALUE; IMPACT;
D O I
10.1111/j.1540-8175.2009.01018.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Both systolic and diastolic tissue Doppler (TD) velocities have an important diagnostic and prognostic role in cardiology. We aimed to compare TD velocities between two different echocardiography systems. Patients: Thirty-one consecutive patients (mean age: 65.2 +/- 17.5 years; 12 males) were enrolled. Methods: Systolic (Sa), early (Ea), and late (Aa) diastolic velocities were measured by TD at the lateral mitral annulus by a Sonos 2000 (Hewlett-Packard, Andover, MA, USA) and a Philips iE33 system. The E/Ea ratio was calculated. Results: Ea, Aa, and Sa velocities were higher when measured by the Sonos system (Ea: 13.2 +/- 4.1 cm/s vs. 8.3 +/- 3.6 cm/s; Aa: 14.8 +/- 3.8 cm/s vs. 9.3 +/- 2.3 cm/s; Sa: 15.2 +/- 3.6 cm/s vs. 8.4 +/- 2.0 cm/s; P < 0.0001 all). A significant correlation was found in Ea and in Ea/Aa (r = 0.84 and r = 0.85 resp; P < 0.0001 for both), and a weaker in Aa (r = 0.43; P = 0.02) between the machines. The Bland-Altman analysis showed broad limits of agreement between the measurements for Ea, Aa, and Sa (mean difference: 4.95 cm/s; 5.52 cm/s; 6.73 cm/s, respectively; limits: 0.64-9.25 cm/s; -1.39-12.39 cm/s; -0.37-13.83 cm/s, respectively). An E/Ea ratio > 5.6 by the Sonos system showed 75% sensitivity and 79% specificity for elevated left ventricular filling pressure, defined as E/Ea > 10 by the reference Philips system. Conclusions: Although diastolic TD velocities had excellent correlations between the two machines, there was a systematic overestimation by the Sonos system. Since the limits of agreement do not allow replacing the measurements, we suggest using the same echocardiographic equipment at patient follow-up. (Echocardiography 2010;27:230-235).
引用
收藏
页码:230 / 235
页数:6
相关论文
共 50 条
  • [31] Assessment of mitral annular velocities by speckle tracking echocardiography versus tissue Doppler imaging: validation, feasibility and reproducibility
    Van Dalen, B. M.
    Bosch, J. G.
    Soliman, O. I. I.
    Vletter, W. B.
    Kauer, F.
    Ten Cate, F. J.
    Geleijnse, M. L.
    EUROPEAN HEART JOURNAL, 2009, 30 : 53 - 53
  • [32] Assessment of Mitral Annular Velocities by Speckle Tracking Echocardiography versus Tissue Doppler Imaging: Validation, Feasibility, and Reproducibility
    van Dalen, Bas M.
    Bosch, Johan G.
    Kauer, Floris
    Soliman, Osama I. I.
    Vletter, Wim B.
    ten Cate, Folkert J.
    Geleijnse, Marcel L.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (11) : 1302 - 1308
  • [33] Clinical in vivo calibration of pulse wave tissue Doppler velocities the assessment of ventricular wall motion. A comparison study with M-mode echocardiography
    Chen, QM
    Li, W
    O'Sullivan, C
    Francis, DP
    Gibson, D
    Henein, MY
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2004, 97 (02) : 289 - 295
  • [34] Protective effect of nebivolol on anthracycline-induced cardiotoxicity, assessed by tissue Doppler velocities and by speckle tracking echocardiography
    Tomescu, M. C.
    Andor, M.
    Citu, I. M.
    Pogorevici, A.
    Mavrea, A.
    Gyalai, I. K.
    Bordejevic, D. A.
    Pop, D.
    EUROPEAN HEART JOURNAL, 2016, 37 : 404 - 405
  • [35] A Comparison of Stochastic Systems with Different Types of Delays
    Banks, H. T.
    Catenacci, Jared
    Hu, Shuhua
    STOCHASTIC ANALYSIS AND APPLICATIONS, 2013, 31 (06) : 913 - 955
  • [36] DESCRIPTION AND COMPARISON OF DIFFERENT TYPES OF PRIMING SYSTEMS
    Kala, Vojtech
    Foitova, Pavia Dernerova
    Mikolas, Milan
    Paus, Pavel
    GEOCONFERENCE ON SCIENCE AND TECHNOLOGIES IN GEOLOGY, EXPLORATION AND MINING, SGEM 2013, VOL I, 2013, : 397 - 401
  • [37] Correlation of tei index obtained from tissue Doppler echocardiography with invasive measurements of left ventricular performance
    Su, Ho-Ming
    Lin, Tsung-Hsien
    Voon, Wen-Chol
    Lee, Kun-Tai
    Chu, Chih-Sheng
    Yen, Hsueh-Wei
    Lai, Wen-Ter
    Sheu, Sheng-Hsiung
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (03): : 252 - 257
  • [38] Comparison of Doppler echocardiography, color M-mode Doppler, and Doppler tissue imaging for the estimation of pulmonary capillary wedge pressure
    González-Vilchez, F
    Ayuela, J
    Ares, M
    Mata, NS
    González, AG
    Durán, RM
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (10) : 1245 - 1250
  • [39] Comparison of Doppler echocardiography, color M-mode Doppler and tissue Doppler imaging for the estimation of pulmonary capillary wedge pressure
    Vilchez, FG
    Ares, MAM
    Ayuela, JAJ
    Mata, NSMNS
    Duran, RMDRM
    de Prada, JAVPJAV
    EUROPEAN HEART JOURNAL, 2001, 22 : 581 - 581
  • [40] Myocardial velocities obtained by pulsed tissue Doppler in English Cocker Spaniels with dilated cardiomyopathy and congestive heart failure
    Pereira, Guilherme G.
    Goldfeder, Guilherme T.
    Yamaki, Fernanda L.
    Oliveira, Valeria M. C.
    Larsson, Maria Helena M. A.
    PESQUISA VETERINARIA BRASILEIRA, 2016, 36 (09): : 851 - 856