Modeling, Simulation, and Optimal Initiation Planning For Needle Insertion Into the Liver

被引:11
|
作者
Sedeh, R. Sharifi [3 ]
Ahmadian, M. T. [2 ]
Janabi-Sharifi, F. [1 ]
机构
[1] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON M5B 2K3, Canada
[2] Sharif Univ Technol, Dept Mech Engn, Tehran 111558639, Iran
[3] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
关键词
genetic algorithm; hyperviscoelastic model; initiation; finite element; liver; needle insertion; surgery simulation; BRAIN-TISSUE; COMPRESSION; ELASTICITY; BREAST;
D O I
10.1115/1.4000953
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Needle insertion simulation and planning systems (SPSs) will play an important role in diminishing inappropriate insertions into soft tissues and resultant complications. Difficulties in SPS development are due in large part to the computational requirements of the extensive calculations in finite element (FE) models of tissue. For clinical feasibility, the computational speed of SPSs must be Unproved. At the same time, a realistic model of tissue properties that reflects large and velocity-dependent deformations must be employed. The purpose of this study is to address the aforementioned difficulties by presenting a cost-effective SPS platform for needle insertions into the liver. The study was constrained to planar (2D) cases, but can be extended to 3D insertions. To accommodate large and velocity-dependent deformations, a hyperviscoelastic model was devised to produce an FE model of liver tissue. Material constants were identified by a genetic algorithm applied to the experimental results of unconfined compressions of bovine liver The approach for SPS involves B-spline interpolations of sample data generated from the FE model of liver Two interpolation-based models are introduced to approximate puncture times and to approximate the coordinates of FE model nodes interacting with the needle tip as a function of the needle initiation pose; the latter was also a function of postpuncture time. A real-time simulation framework is provided, and its computational benefit is highlighted by comparing its performance with the FE method. A planning algorithm for optimal needle initiation was designed, and its effectiveness was evaluated by analyzing its accuracy in reaching a random set of targets at different resolutions of sampled data using the FE model. The proposed simulation framework can easily surpass haptic rates (>500 Hz), even with a high pose resolution level (similar to 30). The computational time required to update the coordinates of the node at the needle tip in the provided example was reduced from 177 s to 0.8069 ms. The planning accuracy was acceptable even with moderate resolution levels: root-mean-square and maximum errors were 1 mm and 1.2 mm, respectively for a pose and PPT resolution levels of 17 and 20, respectively. The proposed interpolation-based models significantly improve the computational speed of needle insertion simulation and planning, based on the discretized (FE) model of the liver and can be utilized to establish a cost-effective planning platform. This modeling approach can also be extended for use in other surgical simulations. [DOI: 10.1115/1.4000953]
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Needle Insertion Modeling through Several Tissue Layers
    Carra, Alexandre
    Avila-Vilchis, Juan Carlos
    2010 2ND INTERNATIONAL ASIA CONFERENCE ON INFORMATICS IN CONTROL, AUTOMATION AND ROBOTICS (CAR 2010), VOL 1, 2010, : 237 - 240
  • [42] Optimal needle design for minimal insertion force and bevel length
    Wang, Yancheng
    Chen, Roland K.
    Tai, Bruce L.
    McLaughlin, Patrick W.
    Shih, Albert J.
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (09) : 1093 - 1100
  • [43] Parametric Modeling and Simulation of Trocar Insertion
    Kesavadas, T.
    Srimathveeravalli, Govindarajan
    Arulesan, Velupillai
    MEDICINE MEETS VIRTUAL REALITY 14: ACCELERATING CHANGE IN HEALTHCARE: NEXT MEDICAL TOOLKIT, 2006, 119 : 252 - 254
  • [44] Path planning for flexible needle based on both insertion mechanism kinematics and needle bending model
    Zhao, Yan-Jiang
    Zhang, He
    Du, Hai-Yan
    Qian, Cheng
    Jin, Ye-Xin
    Chen, Yin
    Yang, Guang-Zhe
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (01):
  • [45] Compensation for Relative Velocity between Needle and Soft Tissue for Friction Modeling in Needle Insertion
    Asadian, Ali
    Patel, Rajni V.
    Kermani, Mehrdad R.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 960 - 963
  • [46] Physical properties of the liver and the development of an intelligent manipulator for needle insertion
    Kobayashi, Y
    Okamoto, J
    Fujie, MG
    2005 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), VOLS 1-4, 2005, : 1632 - 1639
  • [47] Development and validation of a viscoelastic and nonlinear liver model for needle insertion
    Kobayashi, Yo
    Onishi, Akinori
    Hoshi, Takeharu
    Kawamura, Kazuya
    Hashizume, Makoto
    Fujie, Masakatsu G.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2009, 4 (01) : 53 - 63
  • [48] Development and validation of a viscoelastic and nonlinear liver model for needle insertion
    Yo Kobayashi
    Akinori Onishi
    Takeharu Hoshi
    Kazuya Kawamura
    Makoto Hashizume
    Masakatsu G. Fujie
    International Journal of Computer Assisted Radiology and Surgery, 2009, 4 : 53 - 63
  • [49] Physical property of liver for robot-assisted needle insertion
    Kobayashi, Y
    Okamoto, J
    Fujie, MG
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1335 - 1335
  • [50] Simulation and Implementation of Bilateral Teleoperated Needle Insertion via an Endoscope
    Janssens, Jerome
    Catoire, Laurent
    Torfs, Serge
    Kinnaert, Michel
    2015 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2015, : 1737 - 1743