Modeling, Simulation, and Optimal Initiation Planning For Needle Insertion Into the Liver

被引:11
|
作者
Sedeh, R. Sharifi [3 ]
Ahmadian, M. T. [2 ]
Janabi-Sharifi, F. [1 ]
机构
[1] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON M5B 2K3, Canada
[2] Sharif Univ Technol, Dept Mech Engn, Tehran 111558639, Iran
[3] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
关键词
genetic algorithm; hyperviscoelastic model; initiation; finite element; liver; needle insertion; surgery simulation; BRAIN-TISSUE; COMPRESSION; ELASTICITY; BREAST;
D O I
10.1115/1.4000953
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Needle insertion simulation and planning systems (SPSs) will play an important role in diminishing inappropriate insertions into soft tissues and resultant complications. Difficulties in SPS development are due in large part to the computational requirements of the extensive calculations in finite element (FE) models of tissue. For clinical feasibility, the computational speed of SPSs must be Unproved. At the same time, a realistic model of tissue properties that reflects large and velocity-dependent deformations must be employed. The purpose of this study is to address the aforementioned difficulties by presenting a cost-effective SPS platform for needle insertions into the liver. The study was constrained to planar (2D) cases, but can be extended to 3D insertions. To accommodate large and velocity-dependent deformations, a hyperviscoelastic model was devised to produce an FE model of liver tissue. Material constants were identified by a genetic algorithm applied to the experimental results of unconfined compressions of bovine liver The approach for SPS involves B-spline interpolations of sample data generated from the FE model of liver Two interpolation-based models are introduced to approximate puncture times and to approximate the coordinates of FE model nodes interacting with the needle tip as a function of the needle initiation pose; the latter was also a function of postpuncture time. A real-time simulation framework is provided, and its computational benefit is highlighted by comparing its performance with the FE method. A planning algorithm for optimal needle initiation was designed, and its effectiveness was evaluated by analyzing its accuracy in reaching a random set of targets at different resolutions of sampled data using the FE model. The proposed simulation framework can easily surpass haptic rates (>500 Hz), even with a high pose resolution level (similar to 30). The computational time required to update the coordinates of the node at the needle tip in the provided example was reduced from 177 s to 0.8069 ms. The planning accuracy was acceptable even with moderate resolution levels: root-mean-square and maximum errors were 1 mm and 1.2 mm, respectively for a pose and PPT resolution levels of 17 and 20, respectively. The proposed interpolation-based models significantly improve the computational speed of needle insertion simulation and planning, based on the discretized (FE) model of the liver and can be utilized to establish a cost-effective planning platform. This modeling approach can also be extended for use in other surgical simulations. [DOI: 10.1115/1.4000953]
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Simulation for Needle Deflection and Soft Tissue Deformation in Needle Insertion
    Gao, Dedong
    Zheng, Haojun
    MANUFACTURING ENGINEERING AND AUTOMATION I, PTS 1-3, 2011, 139-141 : 889 - +
  • [22] Modeling and Simulation of Friction Forces during Needle Insertion Using Local Constraint Method
    Wang, Lijuan
    Wang, Zhongkui
    Hirai, Shinichi
    2012 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2012, : 4926 - 4932
  • [23] Modeling and Simulation of Flexible Needle Insertion Into Soft Tissue Using Modified Local Constraints
    Gao, Dedong
    Lei, Yong
    Lian, Bin
    Yao, Bin
    JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (12):
  • [24] Overlapping radiofrequency ablation planning and robot-assisted needle insertion for large liver tumors
    Liu, Ping
    Qin, Jing
    Duan, Bin
    Wang, Qiong
    Tan, Xiaoyu
    Zhao, Baoliang
    Jonnathan, Peneyra Libao
    Chui, Chee-Kong
    Heng, Pheng-Ann
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2019, 15 (01):
  • [25] Research on Visual Modeling and Simulation System for Optimal Production Planning
    Zhou Ya-wei
    Pang Ha-li
    2008 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-11, 2008, : 853 - 856
  • [26] Interactive Simulation of Surgical Needle Insertion and Steering
    Chentanez, Nuttapong
    Alterovitz, Ron
    Ritchie, Daniel
    Cho, Lita
    Hauser, Kris K.
    Goldberg, Ken
    Shewchuk, Jonathan R.
    O'Brien, James F.
    ACM TRANSACTIONS ON GRAPHICS, 2009, 28 (03):
  • [27] ENISS: An epidural needle insertion simulation system
    Wolpert, Seth
    Murray, W. Bosseau
    Bethi, Sreelatha
    Yeranilli, Kausalya
    2007 IEEE 33RD ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2007, : 271 - +
  • [28] NEEDLE INSERTION FORCE MODEL FOR HAPTIC SIMULATION
    Gordon, Adam
    Kim, Inki
    Barnett, Andrew C.
    Moore, Jason Z.
    PROCEEDINGS OF THE ASME 10TH INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE, 2015, VOL 2, 2015,
  • [29] Modelling of needle insertion forces for surgical simulation
    Yang, Hua
    Liu, Peter X.
    Zhang, Hadong
    2005 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATIONS, VOLS 1-4, CONFERENCE PROCEEDINGS, 2005, : 592 - 595
  • [30] Force modeling for needle insertion into corneal tissue
    Xuan, Xinxiang
    Yang, Yang
    Wang, Zhe
    Deng, Shijing
    Liu, Xiaoyu
    Gaojishu Tongxin/Chinese High Technology Letters, 2009, 19 (09): : 951 - 956