Modeling, Simulation, and Optimal Initiation Planning For Needle Insertion Into the Liver

被引:11
|
作者
Sedeh, R. Sharifi [3 ]
Ahmadian, M. T. [2 ]
Janabi-Sharifi, F. [1 ]
机构
[1] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON M5B 2K3, Canada
[2] Sharif Univ Technol, Dept Mech Engn, Tehran 111558639, Iran
[3] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
关键词
genetic algorithm; hyperviscoelastic model; initiation; finite element; liver; needle insertion; surgery simulation; BRAIN-TISSUE; COMPRESSION; ELASTICITY; BREAST;
D O I
10.1115/1.4000953
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Needle insertion simulation and planning systems (SPSs) will play an important role in diminishing inappropriate insertions into soft tissues and resultant complications. Difficulties in SPS development are due in large part to the computational requirements of the extensive calculations in finite element (FE) models of tissue. For clinical feasibility, the computational speed of SPSs must be Unproved. At the same time, a realistic model of tissue properties that reflects large and velocity-dependent deformations must be employed. The purpose of this study is to address the aforementioned difficulties by presenting a cost-effective SPS platform for needle insertions into the liver. The study was constrained to planar (2D) cases, but can be extended to 3D insertions. To accommodate large and velocity-dependent deformations, a hyperviscoelastic model was devised to produce an FE model of liver tissue. Material constants were identified by a genetic algorithm applied to the experimental results of unconfined compressions of bovine liver The approach for SPS involves B-spline interpolations of sample data generated from the FE model of liver Two interpolation-based models are introduced to approximate puncture times and to approximate the coordinates of FE model nodes interacting with the needle tip as a function of the needle initiation pose; the latter was also a function of postpuncture time. A real-time simulation framework is provided, and its computational benefit is highlighted by comparing its performance with the FE method. A planning algorithm for optimal needle initiation was designed, and its effectiveness was evaluated by analyzing its accuracy in reaching a random set of targets at different resolutions of sampled data using the FE model. The proposed simulation framework can easily surpass haptic rates (>500 Hz), even with a high pose resolution level (similar to 30). The computational time required to update the coordinates of the node at the needle tip in the provided example was reduced from 177 s to 0.8069 ms. The planning accuracy was acceptable even with moderate resolution levels: root-mean-square and maximum errors were 1 mm and 1.2 mm, respectively for a pose and PPT resolution levels of 17 and 20, respectively. The proposed interpolation-based models significantly improve the computational speed of needle insertion simulation and planning, based on the discretized (FE) model of the liver and can be utilized to establish a cost-effective planning platform. This modeling approach can also be extended for use in other surgical simulations. [DOI: 10.1115/1.4000953]
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Integrative modeling of liver organ for simulation of flexible needle insertion
    Chui, C. -K.
    Teoh, S. -H.
    Ong, C. -J.
    Anderson, J. H.
    Sakuma, I.
    2006 9TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS AND VISION, VOLS 1- 5, 2006, : 2303 - +
  • [2] Needle insertion modeling and simulation
    DiMaio, SP
    Salcudean, SE
    IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 2003, 19 (05): : 864 - 875
  • [3] Modeling of Friction Force based on Relative Velocity between Liver Tissue and Needle for Needle Insertion Simulation
    Kobayashi, Yo
    Sato, Takahiro
    Fujie, Masakatsu G.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5274 - +
  • [4] MODELING THE FLEXIBLE NEEDLE INSERTION INTO THE HUMAN LIVER
    Chiroiu, Veturia
    Nedelcu, Nicoleta
    Munteanu, Ligia
    Rugina, Cristian
    Ionescu, Marius
    Dragne, Ciprian
    PROCEEDINGS OF THE ROMANIAN ACADEMY SERIES A-MATHEMATICS PHYSICS TECHNICAL SCIENCES INFORMATION SCIENCE, 2021, 22 (02): : 163 - 171
  • [5] Modeling of Flexible Needle for Haptic Insertion Simulation
    He, Xuejian
    Chen, Yonghua
    Tang, Libo
    2008 IEEE INTERNATIONAL CONFERENCE ON VIRTUAL ENVIRONMENTS, HUMAN-COMPUTER INTERFACES AND MEASUREMENT SYSTEMS, 2008, : 184 - 189
  • [6] A local constraint method for needle insertion modeling and simulation
    Wang L.
    Hirai S.
    HAVE 2011 - IEEE International Symposium on Haptic Audio-Visual Environments and Games, Proceedings, 2011, : 39 - 44
  • [7] Optimal Planning of Needle Insertion for Robotic-Assisted Prostate Biopsy
    Pisla, Doina
    Gherman, Bogdan
    Girbacia, Florin
    Vaida, Calin
    Butnariu, Silviu
    Girbacia, Teodora
    Plitea, Nicolae
    ADVANCES IN ROBOT DESIGN AND INTELLIGENT CONTROL, 2016, 371 : 339 - 346
  • [8] Mathematical modeling and computer simulation of needle insertion into soft tissue
    Wittek, Adam
    Bourantas, George
    Zwick, Benjamin F.
    Joldes, Grand
    Esteban, Lionel
    Miller, Karol
    PLOS ONE, 2020, 15 (12):
  • [9] A REAL-TIME SIMULATION FOR PATH PLANNING IN NEEDLE INSERTION TASKS
    Konh, Bardia
    Hutapea, Parsaoran
    ASME CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, 2015, VOL 1, 2016,
  • [10] Biomechanical modeling of bone-needle interaction for haptic rendering in needle insertion simulation
    Ong, J. S. K.
    Chui, C. K.
    Wang, Z. L.
    Zhang, J.
    Teo, J. C. M.
    Yang, C. H.
    Ong, S. H.
    Teo, C. L.
    Teoh, S. H.
    2006 9TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS AND VISION, VOLS 1- 5, 2006, : 2332 - +