Behaviour and strength of back-to-back built-up cold-formed steel unequal angle sections with intermediate stiffeners under axial compression

被引:21
|
作者
Ananthi, G. Beulah Gnana [1 ]
Roy, Krishanu [1 ,2 ]
Lim, James B. P. [1 ,2 ]
机构
[1] Anna Univ, Div Struct Engn, Coll Engn, Guindy Campus, Chennai, Tamil Nadu, India
[2] Univ Auckland, Dept Civil & Environm Engn, Auckland, New Zealand
来源
STEEL AND COMPOSITE STRUCTURES | 2022年 / 42卷 / 01期
关键词
axial strength; back-to-back built-up sections; buckling; cold-formed steel; finite element modelling; stiffened unequal angle sections; CHANNEL SECTIONS; NONLINEAR BEHAVIOR; NUMERICAL INVESTIGATIONS; BUCKLING BEHAVIOR; CAPACITY; DESIGN; COLUMNS; TESTS; EDGE; SINGLE;
D O I
10.12989/scs.2022.42.1.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In cold-formed steel (CFS) structures, such as trusses, transmission towers and portal frames, the use of back-toback built-up CFS unequal angle sections are becoming increasingly popular. In such an arrangement, intermediate welds or screw fasteners are required at discrete points along the length, preventing the angle sections from buckling independently. Limited research is available in the literature on axial strength of back-to-back built-up CFS unequal angle sections. The issue is addressed herein. This paper presents an experimental investigation reported by the authors on back-to-back built-up CFS unequal angle sections with intermediate stiffeners under axial compression. The load-axial shortening behaviour along with the deformed shapes at failure are reported. A nonlinear finite element (FE) model was then developed, which includes material non-linearity, geometric imperfections and modelling of intermediate fasteners. The FE model was validated against the experimental test results, which showed good agreement, both in terms of failure loads and deformed shapes at failure. The validated finite element model was then used for the purpose of a parametric study comprising 96 models to investigate the effect of longer to shorter leg ratios, stiffener provided in the longer leg, thicknesses and lengths on axial strength of back-toback built-up CFS unequal angle sections. Four different thicknesses and seven different lengths (stub to slender columns) with three overall widths to the overall depth (B/D) ratios were investigated in the parametric study. Axial strengths obtained from the experimental tests and FE analyses were used to assess the performance of the current design guidelines as per the Direct Strength Method (DSM); obtained comparisons show that the current DSM is conservative by only 7% and 5% on average, while predicting the axial strengths of back-to-back built-up CFS unequal angle sections with and without the stiffener, respectively.
引用
收藏
页码:1 / 22
页数:22
相关论文
共 50 条
  • [31] Strength and deflection behaviour of cold-formed steel back-to-back channels
    Ye, Jun
    Mojtabaei, Seyed Mohammad
    Hajirasouliha, Iman
    Shepherd, Paul
    Pilakoutas, Kypros
    ENGINEERING STRUCTURES, 2018, 177 : 641 - 654
  • [32] Stub Column Tests of Cold-Formed Steel Built-Up Square Sections with Intermediate Stiffeners
    G. Aruna
    Strength of Materials, 2020, 52 : 281 - 290
  • [33] Stub Column Tests of Cold-Formed Steel Built-Up Square Sections with Intermediate Stiffeners
    Aruna, G.
    STRENGTH OF MATERIALS, 2020, 52 (02) : 281 - 290
  • [34] Axial compression behavior of laced cold-formed steel built-up columns with unstiffened angle sections
    Dar, M. Adil
    Sahoo, Dipti Ranjan
    Jain, Arvind K.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 162
  • [35] Analysis to determine flexural buckling of cold-formed steel built-up back-to-back section columns
    Zhou, Tianhua
    Li, Yanchun
    Wu, Hanheng
    Lu, Yan
    Ren, Lujie
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 166 (166)
  • [36] Nonlinear behavior of axially loaded back-to-back built-up cold-formed steel un-lipped channel sections
    Roy, Krishanu
    Ting, Tina Chui Huon
    Lau, Hieng Ho
    Lim, James B. P.
    STEEL AND COMPOSITE STRUCTURES, 2018, 28 (02): : 233 - 250
  • [37] Nonlinear behavior of cold-formed stainless steel built-up box sections under axial compression
    Roy, Krishanu
    Lau, Hieng Ho
    Ahmed, Abdeliazim Mustafa Mohamed
    Lim, James B. P.
    STRUCTURES, 2021, 30 : 390 - 408
  • [38] Axial capacity of back-to-back built-up cold-formed stainless steel unlipped channels-Numerical investigation and parametric study
    Roy, Krishanu
    Lau, Hieng Ho
    Fang, Zhiyuan
    Ahmed, Abdeliazim Mustafa Mohamed
    Lim, James B. P.
    STEEL AND COMPOSITE STRUCTURES, 2021, 40 (05): : 761 - 780
  • [39] Research on post-fire cold-formed steel back-to-back built-up columns with local buckling
    Luo, Kai
    Li, Haifeng
    Yang, Jingjie
    Fang, Sibao
    Yan, Fengzuo
    Yu, Jinglei
    Han, Xue
    Xu, Yuye
    Ning, Xizhan
    THIN-WALLED STRUCTURES, 2025, 209
  • [40] Flexural strength of cold-formed steel built-up box sections
    Xu, Lei
    Sultana, Papia
    Zhou, Xuhong
    THIN-WALLED STRUCTURES, 2009, 47 (6-7) : 807 - 815