Research on post-fire cold-formed steel back-to-back built-up columns with local buckling

被引:0
|
作者
Luo, Kai [1 ]
Li, Haifeng [1 ]
Yang, Jingjie [1 ]
Fang, Sibao [2 ]
Yan, Fengzuo [1 ]
Yu, Jinglei [1 ]
Han, Xue [3 ]
Xu, Yuye [1 ]
Ning, Xizhan [1 ]
机构
[1] Huaqiao Univ, Coll Civil Engn, Xiamen 361021, Peoples R China
[2] Shanghai Baoye Grp Corp Ltd, Shanghai 201900, Peoples R China
[3] Xiamen Inst Technol, Sch Architecture & Civil Engn, Xiamen 361021, Peoples R China
关键词
Cold-formed steel; Local buckling; Post-fire; Built-up section; Direct strength method; DIRECT STRENGTH METHOD; MECHANICAL-PROPERTIES;
D O I
10.1016/j.tws.2024.112883
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cold-formed steel back-to-back built-up columns (CFS-BBC) are extensively used in lightweight steel structures because of their high load-bearing capacity and torsional stiffness. When the CFS structure suffers from a fire, some columns may still be elastic due to low-level internal force, so reusing them after the fire is very economical. However, research on evaluating the residual load-bearing capacity of CFS-BBC after fire exposure is still lacking. This study conducted experimental and finite element analyzes on the post-fire local buckling behavior of CFS-BBC. Experimental research included shear tests of self-tapping screw fasteners after fire exposure and axial compression tests of post-fire CFS-BBC. Subsequently, a finite element model was developed and calibrated, and parametric analyzes were carried out to extensively investigate the local buckling behavior of the CFS-BBC. Test results indicated that the ultimate load-bearing capacity of local buckling CFS-BBC was initially increased and then decreased with the heating-treatment temperatures. After exposure to 600 degrees C, the load-bearing capacity was enhanced by within 10 %. However, there was a 20 % decrease in load-bearing capacity after exposure to 800 degrees C. Based on the test and parametric analysis results, a predictive formula for the reduction factor of the post-fire local buckling load-bearing capacity of CFS-BBC was proposed. Furthermore, the coefficients in the Direct Strength Method (DSM) were modified to have a better prediction when the slenderness factor was relatively small.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Analysis to determine flexural buckling of cold-formed steel built-up back-to-back section columns
    Zhou, Tianhua
    Li, Yanchun
    Wu, Hanheng
    Lu, Yan
    Ren, Lujie
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 166 (166)
  • [2] Global buckling strength of discretely fastened back-to-back built-up cold-formed steel columns
    Mahar, Akshay Mangal
    Jayachandran, S. Arul
    Mahendran, Mahen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 187
  • [3] Design of Cold-Formed Steel Built-Up Back-to-Back Columns Subject to Local-Flexural Interactive Buckling
    Mahar, Akshay Mangal
    Jayachandran, S. Arul
    Mahendran, Mahen
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (12)
  • [4] Research on the flexural buckling behavior of the cold-formed steel back-to-back built-up columns with E-section
    Yang, Jingjie
    Luo, Kai
    Wang, Weiyong
    Shi, Yu
    Li, Haifeng
    ENGINEERING STRUCTURES, 2024, 302
  • [5] Built-up back-to-back cold-formed steel compression members failing by local and distortional buckling
    Vy, Son Tung
    Mahendran, Mahen
    Sivaprakasam, Thananjayan
    THIN-WALLED STRUCTURES, 2021, 159
  • [6] Built-up back-to-back cold-formed steel compression members failing by local and distortional buckling
    Vy, Son Tung
    Mahendran, Mahen
    Sivaprakasam, Thananjayan
    Thin-Walled Structures, 2021, 159
  • [7] A NUMERICAL INVESTIGATION ON COLD-FORMED STEEL BUILT-UP BACK-TO-BACK CHANNEL STUB COLUMNS
    Ting, T. C. H.
    Lau, H. H.
    Proceedings of the 7th International Conference on Steel and Aluminium Structures (ICSAS 2011), 2011, : 443 - 449
  • [8] Compression Test on Cold-Formed Steel Built-up Back-to-Back Channels Stub Columns
    Ting, Chui Huon Tina
    Lau, Hieng Ho
    ADVANCED MANUFACTURING SYSTEMS, PTS 1-3, 2011, 201-203 : 2900 - 2903
  • [9] Design of Cold-Formed Steel Back-To-Back Connected Built-up Beams
    Selvaraj, Sivaganesh
    Madhavan, Mahendrakumar
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 181
  • [10] Research on the elastic buckling of composite webs in cold-formed steel back-to-back built-up columns - Part I: Experimental and numerical investigation
    Zhou, Tianhua
    Li, Yanchun
    Ren, Lujie
    Sang, Liurui
    Zhang, Lei
    STRUCTURES, 2021, 30 : 115 - 133