Research on post-fire cold-formed steel back-to-back built-up columns with local buckling

被引:0
|
作者
Luo, Kai [1 ]
Li, Haifeng [1 ]
Yang, Jingjie [1 ]
Fang, Sibao [2 ]
Yan, Fengzuo [1 ]
Yu, Jinglei [1 ]
Han, Xue [3 ]
Xu, Yuye [1 ]
Ning, Xizhan [1 ]
机构
[1] Huaqiao Univ, Coll Civil Engn, Xiamen 361021, Peoples R China
[2] Shanghai Baoye Grp Corp Ltd, Shanghai 201900, Peoples R China
[3] Xiamen Inst Technol, Sch Architecture & Civil Engn, Xiamen 361021, Peoples R China
关键词
Cold-formed steel; Local buckling; Post-fire; Built-up section; Direct strength method; DIRECT STRENGTH METHOD; MECHANICAL-PROPERTIES;
D O I
10.1016/j.tws.2024.112883
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cold-formed steel back-to-back built-up columns (CFS-BBC) are extensively used in lightweight steel structures because of their high load-bearing capacity and torsional stiffness. When the CFS structure suffers from a fire, some columns may still be elastic due to low-level internal force, so reusing them after the fire is very economical. However, research on evaluating the residual load-bearing capacity of CFS-BBC after fire exposure is still lacking. This study conducted experimental and finite element analyzes on the post-fire local buckling behavior of CFS-BBC. Experimental research included shear tests of self-tapping screw fasteners after fire exposure and axial compression tests of post-fire CFS-BBC. Subsequently, a finite element model was developed and calibrated, and parametric analyzes were carried out to extensively investigate the local buckling behavior of the CFS-BBC. Test results indicated that the ultimate load-bearing capacity of local buckling CFS-BBC was initially increased and then decreased with the heating-treatment temperatures. After exposure to 600 degrees C, the load-bearing capacity was enhanced by within 10 %. However, there was a 20 % decrease in load-bearing capacity after exposure to 800 degrees C. Based on the test and parametric analysis results, a predictive formula for the reduction factor of the post-fire local buckling load-bearing capacity of CFS-BBC was proposed. Furthermore, the coefficients in the Direct Strength Method (DSM) were modified to have a better prediction when the slenderness factor was relatively small.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Mechanics of cold-formed steel built-up box section columns in local buckling modes
    Li, Yanchun
    Li, Ruibo
    Zhou, Tianhua
    Han, Aihong
    Li, Weihua
    STRUCTURES, 2025, 71
  • [22] DSM design of fixed-ended slender built-up back-to-back cold-formed steel compression members
    Son Tung Vy
    Mahendran, Mahen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 189
  • [23] Finite element modelling of back back-to-back built built-up cold cold-formed stainless-steel lipped channels under axial compression
    Roy K.
    Lau H.H.
    Lim J.B.P.
    Steel and Composite Structures, 2019, 33 (01): : 869 - 898
  • [24] Experiments on the global buckling and collapse of built-up cold-formed steel columns
    Fratamico, David C.
    Torabian, Shahabeddin
    Zhao, Xi
    Rasmussen, Kim J. R.
    Schafer, Benjamin W.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 144 : 65 - 80
  • [25] Experimental investigation of the sectional buckling of built-up cold-formed steel columns
    Abbasi, Mandana
    Rasmussen, Kim J. R.
    Khezri, Mani
    Schafer, Benjamin W.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 203
  • [26] Effect of screw spacing on behavior of axially loaded back-to-back cold-formed steel built-up channel sections
    Ting, Tina Chui Huon
    Roy, Krishanu
    Lau, Hieng Ho
    Lim, James B. P.
    ADVANCES IN STRUCTURAL ENGINEERING, 2018, 21 (03) : 474 - 487
  • [27] Flexural behaviour of back-to-back built-up cold-formed steel channel beams: Experiments and finite element modelling
    Roy, Krishanu
    Lau, Hieng Ho
    Ting, Tina Chui Huon
    Chen, Boshan
    Lim, James B. P.
    STRUCTURES, 2021, 29 : 235 - 253
  • [28] Influence of intermediate stiffeners on the axial capacity of cold-formed steel back-to-back built-up unequal angle sections
    Ananthi, G. Beulah Gnana
    Deepak, M. S.
    Roy, Krishanu
    Lim, James B. P.
    STRUCTURES, 2021, 32 : 827 - 848
  • [29] Simulation of screw connected built-up cold-formed steel back-to-back lipped channels under axial compression
    Kechidi, Smail
    Fratamico, David C.
    Schafer, Benjamin W.
    Castro, Jose Miguel
    Bourahla, Nouredine
    ENGINEERING STRUCTURES, 2020, 206
  • [30] Flexural Behavior of Galvanized Iron Based Cold-Formed Steel Back-to-Back Built-Up Beams at Elevated Temperatures
    Sam, Varun Sabu
    Nammalvar, Anand
    Andrushia, Diana
    Gurupatham, Beulah Gnana Ananthi
    Roy, Krishanu
    BUILDINGS, 2024, 14 (08)