Liquid Chromatography-Isotope Dilution-Mass Spectrometry as a New Basis for the Reference Measurement Procedure for Hemoglobin A1c Determination

被引:45
|
作者
Kaiser, Patricia [1 ]
Akerboom, Theodorus [2 ]
Ohlendorf, Ruediger [3 ]
Reinauer, Hans [1 ]
机构
[1] INSTAND eV, Reference Measurement Lab, D-40223 Dusseldorf, Germany
[2] Univ Dusseldorf, Inst Clin Chem & Lab Diagnost, Dusseldorf, Germany
[3] Phys Tech Bundesanstalt, D-3300 Braunschweig, Germany
关键词
PROTEIN QUANTIFICATION; STANDARDIZATION; HBA(1C);
D O I
10.1373/clinchem.2009.139477
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Standardization of hemoglobin (Hb)A(1c) measurements is a process of considerable interest for quality assurance in diabetes management. To contribute to continuous quality improvement and fulfillment of the requirements for reference measurement procedures according to the standards of the International Organization for Standardization, we developed a calibration system of highest metrological order using isotope dilution-mass spectrometry with a reference material. METHOD: Samples were prepared by enzymatic cleavage based on the IFCC reference measurement procedure for LC-MS analysis. After digestion the samples were spiked with [D7]-labeled glycated and nonglycated hexapeptides as internal standards for quantification. LC-MS analysis was performed by using a C12 reversed-phase column and a gradient of acetonitrile/H2O containing 0.1% formic acid. RESULTS: Calibration systems for HbA(1c) determination based on liquid chromatography-isotope dilution-mass spectrometry (LC-ID-MS) and on the IFCC reference measurement procedure were compared. A linear regression analysis demonstrated a correlation of r(2) = 1.00 between the 2 different calibration systems. Mean deviation was 5.5% for the calibration and 3.3% for hemolysate samples, with a mean expanded uncertainty of 4.9%. CONCLUSIONS: This LC-ID-MS procedure allows the current IFCC reference measurement procedure for HbA(1c) to be raised to a higher order of accuracy. (C) 2010 American Association for Clinical Chemistry
引用
收藏
页码:750 / 754
页数:5
相关论文
共 50 条
  • [1] Improved Reference Measurement Method for Hemoglobin A1c by Use of Liquid Chromatography-Isotope Dilution-Tandem Mass Spectrometry
    Wong, Lingkai
    Liu, Hong
    Yong, Sharon
    Liu, Qinde
    Lee, Tong Kooi
    CLINICAL CHEMISTRY, 2015, 61 (02) : 435 - 436
  • [2] Development of hemoglobin A1c certified reference material by liquid chromatography isotope dilution mass spectrometry
    Bi, Jiaming
    Wu, Liqing
    Yang, Bin
    Yang, Yi
    Wang, Jing
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (02) : 549 - 554
  • [3] Development of hemoglobin A1c certified reference material by liquid chromatography isotope dilution mass spectrometry
    Jiaming Bi
    Liqing Wu
    Bin Yang
    Yi Yang
    Jing Wang
    Analytical and Bioanalytical Chemistry, 2012, 403 : 549 - 554
  • [4] Proposed Serum Cholesterol Reference Measurement Procedure by Gas Chromatography-Isotope Dilution Mass Spectrometry
    Edwards, Selvin H.
    Kimberly, Mary M.
    Pyatt, Susan D.
    Stribling, Shelton L.
    Dobbin, Kara D.
    Myers, Gary L.
    CLINICAL CHEMISTRY, 2011, 57 (04) : 614 - 622
  • [5] DETERMINATION OF UREA IN MILK BY LIQUID CHROMATOGRAPHY-ISOTOPE DILUTION MASS SPECTROMETRY
    Dai, Xinhua
    Zhao, Yingchen
    Li, Ming
    Fang, Xiang
    Li, Xiaomin
    Li, Hongmei
    Xu, Bei
    ANALYTICAL LETTERS, 2012, 45 (12) : 1557 - 1565
  • [6] Procedure for Determination of Immunosuppressive Drugs in Whole Blood with Liquid Chromatography-Isotope Dilution Mass Spectrometry
    Molnar, Petra Magdolna
    Dux, Laszlo
    Reinauer, Hans
    Kress, Michael
    Akerboom, Theodorus
    Szederkenyi, Edit
    Kaiser, Patricia
    CLINICAL LABORATORY, 2011, 57 (11-12) : 983 - 992
  • [7] Determination of Serum Growth Hormone by Liquid Chromatography-Isotope Dilution Mass Spectrometry
    Yu L.-X.
    Zhai R.
    Chu Z.-Y.
    Jin Y.-X.
    Wu L.-Q.
    Mi W.
    Gong X.-Y.
    Xie J.
    Jiang Y.
    Dai X.-H.
    Fang X.
    Yu X.-P.
    Journal of Chinese Mass Spectrometry Society, 2021, 42 (02) : 129 - 139
  • [8] DETERMINATION OF GLUCOSE IN REFERENCE MATERIALS BY ISOTOPE DILUTION-MASS SPECTROMETRY
    SCHUMANN, G
    BUTTNER, J
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 330 (4-5): : 424 - 425
  • [9] Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure
    Zhang, Tianjiao
    Zhang, Chuanbao
    Zhao, Haijian
    Zeng, Jie
    Zhang, Jiangtao
    Zhou, Weiyan
    Yan, Ying
    Wang, Yufei
    Wang, Mo
    Chen, Wenxiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (26) : 7403 - 7411
  • [10] Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure
    Tianjiao Zhang
    Chuanbao Zhang
    Haijian Zhao
    Jie Zeng
    Jiangtao Zhang
    Weiyan Zhou
    Ying Yan
    Yufei Wang
    Mo Wang
    Wenxiang Chen
    Analytical and Bioanalytical Chemistry, 2016, 408 : 7403 - 7411